- OVR T2 40-350 C QS
ABB OVR T2 40-350 C QS surge protective device, manufacturer ID 2CTB803886R1000. Arrester class II, one protected pole, plug-in version with replacement cartridge option and status indicator. Intended to protect low-voltage systems against transient overvoltage (lightning) in TT, TN-C, and TN-S systems. Rated voltage 230 V AC; nominal system AC voltage 230/400 V; maximum continuous operating voltage (L-PE) 350 V; temporary overvoltage test value 462 V. Voltage protection level 1.5 kV (L-N), 1.5 kV (N-PE). Nominal discharge current (8/20 µs) 20 kA; maximum discharge current (8/20 µs) 40 kA; impulse current (10/350 µs) 2 kA. Rated service short-circuit breaking capacity and short-circuit withstand 100 kA. DIN-rail mounting, IP20, 17.6 mm wide, 57 mm high, 55.6 mm deep, 0.12 kg. Standards IEC 61643-11 and EN 61643-11.
- OVR T2 40-350 P TS QS
The ABB OVR T2 40-350 P TS QS is a Type 2 surge protective device for low-voltage distribution systems (TT, TN-C, TN-S), intended to protect systems against transient overvoltage from lightning. It is a one-pole, plug-in unit for DIN-rail mounting, with one protected pole and one conductor. Electrical data: rated voltage 230 V AC; system nominal AC voltage 230/400 V; maximum continuous operating voltage 350 V (L-PE); voltage protection level 1.5 kV (L-N); temporary overvoltage test value 462 V. Discharge current is 20 kA nominal (8/20 µs) and 40 kA maximum (8/20 µs); impulse current is 2 kA (10/350 µs). Short-circuit withstand and rated service short-circuit breaking capacity are 100 kA. It complies with IEC 61643-11 and EN 61643-11, has IP20 protection, and includes one NC and one NO auxiliary contact.
- OVR T2 40-440 P QS
The ABB OVR T2 40-440 P QS is a Type 2 surge protective device for low-voltage systems, intended to limit transient overvoltages. It is classified under ETIM 8 and ETIM 9 as EC000941, a surge protection device for power supply systems. Physical data: net width 17.8 mm, net height 88.0 mm, net depth/length 58.0 mm, net weight 0.12 kg, and power loss 0.063 W. It contains no batteries. The manufacturer identifier is 2TAM201000R4800. The dimension diagram reference is 2CTC800021F0102, and the object classification code is F. WEEE category 5 applies, and the WEEE B2C/B2B designation is Business To Consumer; the CN8 code is 8536909000.
- OVR T2 40-440 P TS QS
The ABB OVR T2 40-440 P TS QS is a Type II surge protective device for low-voltage distribution systems, suitable for TT, TN-C, TN-S, and IT configurations. It is rated 230 V AC with a maximum continuous operating voltage (L-PE) of 440 V and a voltage protection level of 1.8 kV (L-N, N-PE). Nominal discharge current is 20 kA (8/20 µs) and maximum discharge current is 40 kA (8/20 µs); impulse current is 2 kA (10/350 µs). Short-circuit withstand is 100 kA. It has one protected pole, one pole, one conductor, one NC and one NO auxiliary contact, a status indicator, and a plug-in DIN-rail mount. Dimensions are 17.8 mm wide, 95 mm high, 58 mm deep; weight 0.12 kg. Standards: IEC 61643-11 / EN 61643-11.
- OVR T2 40-440 P TS U
The ABB OVR T2 40-440 P TS U is a plug-in, single-pole surge protective device for DIN-rail mounting, classified as arrester class II. It is rated 347 V AC (Ur) with a maximum continuous operating voltage of 440 V L-PE and a voltage protection level of 1.4 kV L-N. Nominal discharge current is 10 kA (8/20 µs) and maximum discharge current is 40 kA (8/20 µs). Short-circuit withstand and rated service short-circuit breaking capacity are both 100 kA; SCCR is 200 kA. It provides one NC and one NO auxiliary contact rated 12 Vdc at 10 mA minimum to 250 Vac at 1 A maximum, a status indicator, IP20 protection, and dimensions of 17.8 mm by 98.5 mm by 64.8 mm.
- OVR T2 40-440s C QS
ABB OVR T2 40-440s C QS surge protective device, Type II arrester for low-voltage distribution systems (TT, TN-C, TN-S, IT). Rated voltage Ur 230 V AC; nominal system AC voltage Uo 400 / 690 V; maximum continuous operating voltage Uc 440 V (L-PE). Voltage protection level Up 1.4 kV (L-N), 1.8 kV (N-PE). Nominal discharge current 20 kA (8/20 µs), maximum 40 kA (8/20 µs); impulse current 2 kA (10/350 µs). Rated service short-circuit breaking capacity and short-circuit withstand 100 kA. One protected pole, plug-in version with replacement cartridge, status indicator, and preventive maintenance feature. DIN-rail mounting, IP20, 17.6 mm wide, 57 mm high, 67 mm deep, 0.075 kg. Standards: IEC 61643-11 / EN 61643-11.
- OVR T2 40-440s P QS
The ABB OVR T2 40-440s P QS is a Type 2 surge protective device for low-voltage distribution systems, intended to protect against transient overvoltages such as those caused by lightning. It is rated 400 V AC (Ur), with a maximum continuous operating voltage (L-PE) of 440 V and a voltage protection level of 1.8 kV (L-N), 1.8 kV (N-PE). Nominal discharge current is 20 kA (8/20 µs) and maximum discharge current is 40 kA (8/20 µs); impulse current is 2 kA (10/350 µs). Short-circuit withstand is 100 kA. The device is a single-pole, plug-in unit for DIN-rail mounting, IP20, 1 modular spacing (17.8 mm wide, 88 mm high, 76.7 mm deep, 0.15 kg), with status indicator and preventive maintenance feature. Standards: IEC 61643-11 / EN 61643-11.
- OVR T2 40-440s P TS QS
The ABB OVR T2 40-440s P TS QS is a Type II surge protective device for low-voltage distribution systems TT, TN-C, TN-S and IT, intended to protect systems against transient overvoltage from lightning. It complies with IEC 61643-11 and EN 61643-11. Rated voltage Ur is 400 V AC; maximum continuous operating voltage Uc is 440 V (L-PE); temporary overvoltage test value UT is 581 V. Nominal discharge current is 20 kA (8/20 µs) and maximum discharge current is 40 kA (8/20 µs); impulse current is 2 kA (10/350 µs). Voltage protection level Up is 1.8 kV (L-N), 1.8 kV (N-PE). It has one protected pole, one pole, one conductor, one NC and one NO auxiliary contact, plug-in version, DIN-rail mounting, IP20, 17.8 mm wide, 95.8 mm high, 76.7 mm deep, 0.15 kg.