Industrial Automation Parts. Prompt replies from real people.

ABB B6-40-00-P-80 4-Pole Mini Contactor

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/26/2026

Q1Can you supply the ABB B6-40-00-P-80?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the ABB B6-40-00-P-80 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
B6-40-00-P-80
Material Number
GJL1211209R8000
Manufacturer
ABB
Product ID
76890

Get a Free Quote

Request pricing and availability for B6-40-00-P-80.

More parts to source? Send your whole list in one enquiry

Key specifications

Product Net Weight
0.17 kg
Rated Operational Voltage
Main Circuit 690 V AC Main Circuit 220 V DC
Rated Frequency (f)
Control Circuit 400 Hz Control Circuit 50 Hz Control Circuit 60 Hz Main Circuit 60 Hz Main Circuit 50 Hz Main Circuit DC
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 6 kV
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 40 °C 12 A (220 / 240 V) 55 °C 12 A (380 / 440 V) 40 °C 12 A (380 / 440 V) 55 °C 12 A (690 V) 40 °C 6 A (690 V) 55 °C 6 A
Rated Operational Power AC-3 (Pe)
(230 V) Three Phase 2.2 kW (400 V) Three Phase 4 kW (500 V) Three Phase 4 kW (690 V) Three Phase, NO 3 kW
See all specifications

Product Highlights

  1. Contact Configuration: 4-pole mini contactor with 4 normally open main contacts and no auxiliary contacts
  2. Switching Capacity: Rated operational current 12 A AC-1 up to 440 V and 6 A at 690 V, with three-phase AC-3 power ratings of 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V
  3. Coil and Control: 220 to 240 V AC control circuit voltage with operating limits of 0.85 to 1.1 x Uc at ambient temperatures up to 55 °C
  4. Mounting and Dimensions: 47.5 mm wide, 45.2 mm high, and 47.7 mm deep, suitable for TH35-15 and TH35-7.5 DIN rail mounting
  5. Durability and Environment: Mechanical durability of 10,000,000 cycles, operating temperature range of -20 to +55 °C, and maximum operating altitude of 2000 m
B6-40-00-P-80

Product Information

Technical Specifications

Specifications for B6-40-00-P-80

ParameterValue
Product Net Width47.5 mm
Product Net Height45.2 mm
Product Net Depth / Length47.7 mm
Product Net Weight0.17 kg
Number of Poles4
Mini Contactor TypeMini Contactor
Rated Operational VoltageMain Circuit 690 V AC Main Circuit 220 V DC
Rated Frequency (f)Control Circuit 400 Hz Control Circuit 50 Hz Control Circuit 60 Hz Main Circuit 60 Hz Main Circuit 50 Hz Main Circuit DC
Rated Impulse Withstand Voltage (Uimp)Main Circuit 6 kV
Rated Insulation Voltage (Ui)690 V acc. to UL/CSA 600 V
Number of Main Contacts NC0
Number of Main Contacts NO4
Rated Operational Current AC-1 (Ie)(220240 V) 40 °C 12 A (220240 V) 55 °C 12 A (380440 V) 40 °C 12 A (380440 V) 55 °C 12 A (690 V) 40 °C 6 A (690 V) 55 °C 6 A
Rated Operational Power AC-3 (Pe)(230 V) Three Phase 2.2 kW (400 V) Three Phase 4 kW (500 V) Three Phase 4 kW (690 V) Three Phase, NO 3 kW
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 64 A
Number of Auxiliary Contacts NC0
Number of Auxiliary Contacts NO0
Conventional Free-air Thermal Current (Ith)Main Circuit 12 A
Rated Control Circuit Voltage (Uc)220 ... 240 V AC
ParameterValue
Coil Operating Limits(acc. to IEC 60947-4-1) for AC supply 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
Degree of ProtectionControl Circuit Terminals IP20 Main Circuit Terminals IP20
Mechanical Durability10000000 cycle
Maximum Electrical Switching Frequency(AC-1) 300 cycles per hour (AC-3) 600 cycles per hour (DC-1) 600 cycles per hour (DC-3) 600 cycles per hour
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Power Lossat Rated Operating Conditions AC-1 per Pole 1 W
StandardsIEC/EN 60947-1 IEC/EN 60947-4-1 IEC/EN 60947-5-1 UL 60947-1 UL 60947-4-1 IEC 60335-2-40 A2L
Maximum Operating Voltage UL/CSAMain Circuit 600 V AC
Full Load Amps Motor Use(115 V AC) Single Phase 5.8 A (200 V AC) Three Phase 4.8 A (220 ... 240 V AC) Three Phase 6.8 A (230 V AC) Single Phase 4.9 A (440 ... 480 V AC) Three Phase 4.8 A (550 ... 600 V AC) Three Phase 1.7 A
Horsepower Rating UL/CSA(115 V AC) Single Phase 0.25 Hp (200 V AC) Three Phase 1 Hp (220 ... 240 V AC) Three Phase 2 Hp (230 V AC) Single Phase 0.5 Hp (440 ... 480 V AC) Three Phase 3 Hp (550 ... 600 V AC) Three Phase 1 Hp
General Use Rating UL/CSA(300 V AC) 8 A
Ambient Air TemperatureOperation -20 ... +55 °C Storage -40 ... +80 °C
Maximum Operating Altitude Permissible2000 m
Resistance to Shock acc. to IEC 60068-2-2711 ms Pulse 15g
Resistance to Vibrations5g 5 ... 150 Hz
Object Classification CodeQ
ETIM 4EC000066 - Magnet contactor, AC-switching
ETIM 5EC000066 - Magnet contactor, AC-switching
ETIM 6EC000066 - Power contactor, AC switching
ETIM 7EC000066 - Power contactor, AC switching
ETIM 8EC000066 - Power contactor, AC switching
eClassV11.0 : 27371003
UNSPSC39121529
Manufacturer IDGJL1211209R8000

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp