- DDA202 AC-40/0.03
ABB DDA202 AC-40/0.03 is a 2-pole residual current device module with a rated current of 40 A and rated residual current of 30 mA. It is Type AC, with a rated operational voltage of 230 V and rated voltage of 230/400 V at 50 to 60 Hz. Rated insulation voltage is 500 V and rated impulse withstand voltage is 4 kV. Power loss is 3.2 W, electrical endurance is 10000 cycles, and operating characteristic is instantaneous. Connecting capacity is rigid 25 to 25 mm² and flexible 25 to 25 mm². Ambient operating temperature is -25 to 55 °C, degree of protection is IP2X, and net dimensions are 70 mm width, 93 mm height, and 76 mm depth, weighing 210 g. Standards: IEC/EN 61009 Ann. G.
- DDA202 AC-40/0.1
ABB DDA202 AC-40/0.1 leakage protector, 2-pole, rated current 40 A, rated residual current 100 mA, Type AC residual current. Rated voltage 230/400 V, rated operational voltage 230 V, rated insulation voltage 500 V, rated impulse withstand voltage 4 kV, rated frequency 50 to 60 Hz. Instantaneous operating characteristic, electrical endurance 10000 cycles, power loss 3.2 W. Connecting capacity rigid 25 to 25 mm² and flexible 25 to 25 mm². Ambient temperature -25 to 55 °C, degree of protection IP2X. Dimensions 70 mm width, 93 mm height, 76 mm depth, net weight 210 g. Standards IEC/EN 61009 Ann. G. Manufacturer ID 2CSB202001R2400.
- DDA202 AC-40/0.3
ABB DDA202 AC-40/0.3 leakage protector, Type AC, rated residual current 300 mA, rated current 40 A, two poles, instantaneous operating characteristic. Rated voltage 230/400 V, rated operational voltage 230 V, rated insulation voltage 500 V, rated impulse withstand voltage 4 kV, rated frequency 50 to 60 Hz. Complies with IEC/EN 61009 Ann. G. Power loss 3.2 W; electrical endurance 10000 cycles. Connecting capacity rigid 25 to 25 mm², flexible 25 to 25 mm². Ambient operating temperature -25 to 55 °C. Degree of protection IP2X. Dimensions 70 mm width, 93 mm height, 76 mm depth; net weight 210 g. Manufacturer ID 2CSB202001R3400.
- DDA202 AC-40/0.5
ABB DDA202 AC-40/0.5 leakage protector, Type AC residual current device. Rated current 40 A, rated residual current 500 mA, rated voltage 230/400 V, rated operational voltage 230 V, rated frequency 50 to 60 Hz. Two poles, instantaneous operating characteristic. Complies with IEC/EN 61009 Ann. G. Rated insulation voltage 500 V, rated impulse withstand voltage 4 kV, power loss 3.2 W, electrical endurance 10000 cycles. Connecting capacity for rigid and flexible conductors 25 to 25 mm². Ambient operating temperature -25 to 55 °C, degree of protection IP2X. Dimensions 70 mm width, 93 mm height, 76 mm depth; net weight 210 g. Manufacturer ID 2CSB202001R4400.
- DDA202 AC-40/1
ABB DDA202 AC-40/1 is a two-pole residual current circuit breaker (RCCB) with Type AC residual current detection. It is rated 40 A, 1000 mA residual current, 230/400 V, 50 to 60 Hz, with an instantaneous operating characteristic. Rated insulation voltage is 500 V and rated impulse withstand voltage is 4 kV. It conforms to IEC/EN 61009 Ann. G. Electrical endurance is 10000 cycles and power loss is 3.2 W. Connecting capacity is rigid 25 to 25 mm² and flexible 25 to 25 mm². Ambient operating temperature is -25 to 55 °C, degree of protection is IP2X, and net dimensions are 70 mm width, 93 mm height, and 76 mm depth, weighing 210 g.
- DDA202 AC-63/0.03
ABB DDA202 AC-63/0.03 leakage protector, 2-pole, rated current 63 A, rated residual current 30 mA, Type AC residual current, instantaneous operating characteristic. Rated voltage 230/400 V, rated operational voltage 230 V, rated insulation voltage 500 V, rated impulse withstand voltage 4 kV, rated frequency 50 to 60 Hz. Complies with IEC/EN 61009 Ann. G. Power loss 5 W; electrical endurance 10000 cycles. Connecting capacity rigid 25 to 25 mm² and flexible 25 to 25 mm². Ambient operating temperature -25 to 55 °C. Degree of protection IP2X. Dimensions 70 mm width, 93 mm height, 76 mm depth; net weight 210 g. Manufacturer ID 2CSB202001R1630.
- DDA202 AC-63/0.1
The ABB DDA202 AC-63/0.1 is a Type AC residual current device block with a rated residual current of 100 mA and rated current of 63 A. It is a two-pole device with instantaneous operating characteristic, rated voltage 230/400 V, rated operational voltage 230 V, rated insulation voltage 500 V, and rated impulse withstand voltage 4 kV. Rated frequency is 50 to 60 Hz. It conforms to IEC/EN 61009 Ann. G. Connecting capacity is rigid 25 to 25 mm² and flexible 25 to 25 mm². Electrical endurance is 10000 cycles, power loss 5 W, degree of protection IP2X, and ambient operating temperature -25 to 55 °C. Dimensions are 70 mm width, 93 mm height, 76 mm depth, and net weight 210 g.
- DDA202 AC-63/0.3
The ABB DDA202 AC-63/0.3 is a Type AC residual current circuit breaker module with a rated residual current of 300 mA and rated current of 63 A. It is a two-pole device with instantaneous operating characteristic, rated operational voltage of 230 V, rated voltage of 230/400 V, and rated frequency of 50 to 60 Hz. Rated insulation voltage is 500 V and rated impulse withstand voltage is 4 kV. It conforms to IEC/EN 61009 Ann. G. Power loss is 5 W and electrical endurance is 10000 cycles. Connecting capacity is rigid 25 to 25 mm² and flexible 25 to 25 mm². Ambient operating temperature range is -25 to 55 °C, with degree of protection IP2X. Dimensions are 70 mm width, 93 mm height, and 76 mm depth, with a net weight of 210 g.