- B7-40-00-80
The ABB B7-40-00-80 is a four-pole mini AC contactor with four normally open main contacts and no auxiliary or normally closed contacts. It measures 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.175 kg. The control circuit is rated 220 to 240 V AC at 50 Hz, 60 Hz, or 400 Hz, with coil operating limits of 0.85 to 1.1 times Uc according to IEC 60947-4-1 at ambient temperatures up to 55 °C. Main circuit ratings include 690 V AC and 220 V DC, 6 kV impulse withstand, and 20 A AC-1 at 40 °C. AC-3 power ratings are 3 kW at 230 V and 5.5 kW at 400 V or 500 V, three-phase. Mechanical durability is 10,000,000 cycles.
- B7-40-00-84
The ABB B7-40-00-84 is a 4-pole mini contactor with four normally open main contacts and no auxiliary contacts. It measures 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.175 kg. The control circuit is rated 110 to 127 V AC, with coil operating limits of 0.85 to 1.1 times Uc according to IEC 60947-4-1 at ambient temperatures up to 55 °C. Rated operational current AC-1 is 20 A at 220/240 V and 380/440 V at 40 °C, and 16 A at those voltages at 55 °C. Rated operational power AC-3 is 5.5 kW at 400 V and 500 V three-phase. Mechanical durability is 10,000,000 cycles. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- B7-40-00-85
The ABB B7-40-00-85 is a 4-pole mini contactor with four normally open main contacts and no auxiliary contacts. It measures 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.175 kg. The control circuit is rated 380 to 415 V AC, with coil operating limits of 0.85 to 1.1 times Uc according to IEC 60947-4-1 at ambient temperatures up to 55 °C. Main circuit ratings include 690 V AC and 220 V DC, 6 kV impulse withstand, and 20 A AC-1 at 40 °C. AC-3 rated power is 5.5 kW at 400 V and 500 V three-phase. Terminals accept rigid 1 to 4 mm² and flexible 1 to 2.5 mm² conductors. Mounting is on TH35-15 or TH35-7.5 DIN rail per IEC 60715. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- B7-40-00-F-01
The ABB B7-40-00-F-01 is a four-pole mini contactor with four normally open main contacts and no normally closed main or auxiliary contacts. It measures 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.17 kg. The main circuit is rated 690 V AC and 220 V DC, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V. The control circuit operates at 24 V AC. Rated operational current is 20 A at 220/240 V and 380/440 V at 40 degrees C, and 6 A at 690 V. Rated operational power AC-3 is 5.5 kW at 400 V and 500 V. The contactor mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715.
- B7-40-00-F-02
The ABB B7-40-00-F-02 is a 4-pole mini contactor with four normally open main contacts and no auxiliary contacts. It measures 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.17 kg. The main circuit is rated 690 V AC and 220 V DC, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 3 kW at 230 V, 5.5 kW at 400 V and 500 V, and 3 kW at 690 V. The control circuit voltage is 42 V AC. Mechanical durability is 10,000,000 cycles. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1.
- B7-40-00-F-80
The ABB B7-40-00-F-80 is a 4-pole mini contactor with four normally open main contacts and no normally closed or auxiliary contacts. It measures 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.17 kg. The control circuit is rated 220 to 240 V AC, and the main circuit is rated 690 V AC or 220 V DC. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220 to 440 V, and 6 A at 690 V. Rated operational power AC-3 is 3 kW at 230 V, 5.5 kW at 400 V and 500 V, and 3 kW at 690 V. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715.
- B7-40-00-F-84
ABB B7-40-00-F-84 miniature AC contactor with four normally open main contacts and no auxiliary contacts. Rated operational voltage is 690 V AC for the main circuit and 220 V DC; rated insulation voltage is 690 V according to UL/CSA and 600 V. The coil is rated 110 to 127 V AC, 50/60 Hz and 400 Hz, with operating limits of 0.85 to 1.1 x Uc according to IEC 60947-4-1 at ambient temperatures up to 55 °C. Rated operational power AC-3 is 3 kW at 230 V three-phase, 5.5 kW at 400 V and 500 V three-phase, and 3 kW at 690 V three-phase. Dimensions are 52.5 mm wide, 57.5 mm high, and 46.7 mm deep; weight 0.17 kg. Mechanical durability is 10,000,000 cycles.
- B7-40-00-F-85
The ABB B7-40-00-F-85 is a 4-pole mini contactor with four normally open main contacts and no auxiliary contacts. It has a rated operational voltage of 690 V AC for the main circuit and 220 V DC, and a rated control circuit voltage of 380 to 415 V AC. Rated operational current AC-1 is 20 A at 220/240 V and 380/440 V at 40 °C, and 6 A at 690 V. Rated operational power AC-3 is 5.5 kW at 400 V and 500 V three-phase. Dimensions are 52.5 mm width, 57.5 mm height, and 46.7 mm depth, with a net weight of 0.17 kg. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.