Product Model
LS45P13B11
Material Number
1SBV012413R1211
Manufacturer
ABB
Product ID
76431

Get a Free Quote

Request pricing and availability for LS45P13B11.

More parts to source? Send your whole list in one enquiry

Key specifications

Product Net Weight
0.139 kg
Degree of Protection
acc. to IEC 60529 IP65
Maximum Electrical Switching Frequency
3600 cycles per hour (AC-15) 3600 cycles per hour (DC-13) 3600 cycles per hour
Rated Impulse Withstand Voltage (Uimp)
6 kV
Rated Operational Current AC-15 (Ie)
(230 V AC) 3.1 A (400 V) NC 4 (24 V) 10 A (130 V) 5.5 A (240 V) 3 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 500 V acc. to UL/CSA 600 V
See all specifications

Product Highlights

  1. Housing and Flammability: Plastic housing rated UL94 V-0 with IP65 protection to IEC 60529 and Class II double insulation to IEC 536
  2. Actuator and Head: Steel roller plunger with C-shape operating head to EN 50041 and head adjustable in 90° increments
  3. Contact and Switching: Snap-action Zb contact element with 1 NO and 1 NC auxiliary contacts, positive opening of NC contacts, 10 A conventional thermal current at 40 °C, and 6 kV rated impulse withstand voltage
  4. Operating Limits: Minimum actuating force 16 N, minimum positive opening force 48 N, maximum actuation speed 0.5 m/s, and ambient operating temperature -25 to +70 °C
  5. Durability and Mounting: Mechanical durability 10 million operations, B10d value 50 million operations, consistency 0.1 mm over 1 million operations, and 40 mm EN 50041 mounting with 2 or 4 M5 screws
LS45P13B11

Product Information

Technical Specifications

Specifications for LS45P13B11

ParameterValue
Product Net Width41 mm
Product Net Height117 mm
Product Net Depth / Length41 mm
Product Net Weight0.139 kg
Action Type of the Contact Element (acc. to IEC 60947-5-1)Snap action contacts
Actuating ForceMinimum Force acc. to IEC 60947-5-1 16 N
Actuation Speedacc. to IEC 60947-5-1 Max. 0.5 m/s
Actuator Typesteel roller plunger
Angular Head Adjustmentadjustable head every 90°
Angular Lever Adjustmentnone
B10d ValueOperations 50 Millions
Climatic Withstandaccording to IEC 68-2-3 and salty mist according to IEC 68-2-11
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-5-1, Θ = 40 °C 10 A
Connecting CapacityBar AWG 20 ... AWG 14 mm² Bar 0.5 ... 2.5 mm²
Consistency (Measured over 1 Million Operations)0.1 mm
Contact Element Form (acc. to IEC 60947-5-1)Zb
Connecting Terminals (delivered in open position)M3.5 (+,-) pozidriv 2 screw with cable clamp
Degree of Protectionacc. to IEC 60529 IP65
Electrical Shock Protection acc. to IEC 536Double insulation - Class II
Flammability According to UL94V-0
Housing MaterialPlastic
Maximum Electrical Switching Frequency3600 cycles per hour (AC-15) 3600 cycles per hour (DC-13) 3600 cycles per hour
Maximum Mounted Auxiliary Contacts1 NO, 1 NC
Mechanical Durability10 million
Mounting Type40 mm (EN 50041)
Mounting by Screws (not supplied)2 or 4 x M5 screws
Movement to be DetectedOn end or 30° Cam Translation
ParameterValue
Number of Auxiliary Contacts NC1
Number of Auxiliary Contacts NO1
Number and Type of Bottom Cable Glands1/2 NPT cable gland
Operating Head ShapeC shape acc. EN 50041
Pilot Duty UL/CSAA600 Q600
Positive Opening Operation Force (Direct Opening Action)Minimum Force acc. to IEC 60947-5-1 48
Positive Opening Operation of NC Contact(s)Yes
Rated Impulse Withstand Voltage (Uimp)6 kV
Rated Operational Current AC-15 (Ie)(230 V AC) 3.1 A (400 V) NC 4 (24 V) 10 A (130 V) 5.5 A (240 V) 3 A
Rated Frequency (f)Supply Circuit 50 / 60 Hz
Rated Insulation Voltage (Ui)acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 500 V acc. to UL/CSA 600 V
Rated Operational Current DC-13 (Ie)(24 V) 6 A (110 V) 0.6 A (125 V) 0.55 A (250 V) 0.4 A
Resistance Between Contacts25 ms
Short-Circuit Protective DevicesgG Type Fuses 10 A
Terminal Markingaccording to EN 50013
Ambient Air TemperatureOperation -25 ... +70 °C Storage -30 ... +80 °C
Resistance to Shock acc. to IEC 60068-2-27Half-sine Pulse for 11 ms, No Change in Contact Position 50 m/s²
Resistance to VibrationsNo Change in Position of Contacts Greater than 100 µs: 25g 10 ... 500 Hz
Object Classification CodeB
ETIM 6EC000030 - End switch
ETIM 7EC000030 - End switch
ETIM 8EC000030 - End switch
eClassV11.0 : 27272601
UNSPSC39122213
IDEA Granular Category Code (IGCC)5202 >> Limit switch
Manufacturer ID1SBV012413R1211

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp