Industrial Automation Parts. Prompt replies from real people.

ABB LS45M11B11 Limit Switch

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/24/2026

Q1Can you supply the ABB LS45M11B11?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the ABB LS45M11B11 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
LS45M11B11
Material Number
1SBV013111R1211
Manufacturer
ABB
Product ID
76311

Get a Free Quote

Request pricing and availability for LS45M11B11.

More parts to source? Send your whole list in one enquiry

Key specifications

Product Net Weight
0.222 kg
Degree of Protection
acc. to IEC 60529 IP66
Maximum Electrical Switching Frequency
3600 cycles per hour (AC-15) 3600 cycles per hour (DC-13) 3600 cycles per hour
Rated Impulse Withstand Voltage (Uimp)
6 kV
Rated Operational Current AC-15 (Ie)
(230 V AC) 3.1 A (400 V) NC 4 (24 V) 10 A (130 V) 5.5 A (240 V) 3 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 500 V acc. to UL/CSA 600 V
See all specifications

Product Highlights

  1. Contact Configuration: 1 NO and 1 NC auxiliary contacts in Zb form with snap action, positive opening of the NC contact, and a minimum direct opening force of 66 N
  2. Actuator and Adjustment: Stainless steel plain plunger with a B-shape operating head per EN 50041 and an adjustable head every 90°
  3. Electrical Ratings: 10 A conventional thermal current, 500 V rated insulation voltage (600 V per UL/CSA), 6 kV impulse withstand voltage, and A600/Q600 pilot duty
  4. Durability: 25 million mechanical operations and a B10d value of 50 million operations
  5. Environment and Mounting: IP66 protection, -25 to +70 °C operating temperature, 40 mm EN 50041 mounting with 2 or 4 M5 screws, and a 1/2 NPT bottom cable gland
LS45M11B11

Product Information

Technical Specifications

Specifications for LS45M11B11

ParameterValue
Product Net Width40 mm
Product Net Height107 mm
Product Net Depth / Length44 mm
Product Net Weight0.222 kg
Action Type of the Contact Element (acc. to IEC 60947-5-1)Snap action contacts
Actuating ForceMinimum Force acc. to IEC 60947-5-1 22 N
Actuation Speedacc. to IEC 60947-5-1 Max. 0.5 m/s
Actuator Typestainless steel plain plunger
Angular Head Adjustmentadjustable head every 90°
Angular Lever Adjustmentnone
B10d ValueOperations 50 Millions
Climatic Withstandaccording to IEC 68-2-3 and salty mist according to IEC 68-2-11
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-5-1, Θ = 40 °C 10 A
Connecting CapacityBar AWG 20 ... AWG 14 mm² Bar 0.5 ... 2.5 mm²
Consistency (Measured over 1 Million Operations)0.05 mm
Contact Element Form (acc. to IEC 60947-5-1)Zb
Connecting Terminals (delivered in open position)M3.5 (+,-) pozidriv 2 screw with cable clamp
Degree of Protectionacc. to IEC 60529 IP66
Electrical Shock Protection acc. to IEC 536Class I
Housing MaterialMetal
Maximum Electrical Switching Frequency3600 cycles per hour (AC-15) 3600 cycles per hour (DC-13) 3600 cycles per hour
Maximum Mounted Auxiliary Contacts1 NO, 1 NC
Mechanical Durability25 million
Mounting Type40 mm (EN 50041)
Mounting by Screws (not supplied)2 or 4 x M5 screws
Movement to be Detectedon end
Number of Auxiliary Contacts NC1
ParameterValue
Number of Auxiliary Contacts NO1
Number and Type of Bottom Cable Glands1/2 NPT cable gland
Operating Head ShapeB shape acc. EN 50041
Pilot Duty UL/CSAA600 Q600
Positive Opening Operation Force (Direct Opening Action)Minimum Force acc. to IEC 60947-5-1 66
Positive Opening Operation of NC Contact(s)Yes
Rated Impulse Withstand Voltage (Uimp)6 kV
Rated Operational Current AC-15 (Ie)(230 V AC) 3.1 A (400 V) NC 4 (24 V) 10 A (130 V) 5.5 A (240 V) 3 A
Rated Frequency (f)Supply Circuit 50 / 60 Hz
Rated Insulation Voltage (Ui)acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 500 V acc. to UL/CSA 600 V
Rated Operational Current DC-13 (Ie)(24 V) 6 A (110 V) 0.6 A (125 V) 0.55 A (250 V) 0.4 A
Resistance Between Contacts25 ms
Short-Circuit Protective DevicesgG Type Fuses 10 A
Terminal Markingaccording to EN 50013
Terminal for Protective ConductorM 3.5 (+,-) pozidriv 2 screw with cable clamp
Ambient Air TemperatureOperation -25 ... +70 °C Storage -30 ... +80 °C
Resistance to Shock acc. to IEC 60068-2-27Half-sine Pulse for 11 ms, No Change in Contact Position 50 m/s²
Resistance to VibrationsNo Change in Position of Contacts Greater than 100 µs: 25g 10 ... 500 Hz
Object Classification CodeB
ETIM 6EC000030 - End switch
ETIM 7EC000030 - End switch
ETIM 8EC000030 - End switch
eClassV11.0 : 27272601
UNSPSC39122213
IDEA Granular Category Code (IGCC)5202 >> Limit switch
Manufacturer ID1SBV013111R1211

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp