- OS125GB03N3
ABB OS125GB03N3 fuse switch disconnector, 3+N poles, rated current 125 A. Rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 8 kV. Conventional free-air thermal current 125 A at 40 °C; conventional thermal current 125 A fully enclosed. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 5 kA rms for 1 s. Rated operational power AC-23A: 37 kW at 220–240 V, 55 kW at 400 V and 415 V, 75 kW at 500 V, 110 kW at 690 V. Fuse size A2–A4, British Standard fuse system. Detachable neutral link integrated into the mechanism. Base mounting, front operated, lug terminals 20 mm, tightening torque 15–22 N·m. Pollution degree 3. Standards: IEC 60947-3. Handle and shaft not included. Dimensions 147 x 140 x 115 mm; net weight 2.08 kg.
- OS125GB03N3-42
The ABB OS125GB03N3-42 is a manually operated fuse switch disconnector with a 125 A main circuit rating, 3+N poles, and a detachable neutral link integrated into the mechanism. It is front operated with a left-side mechanism (03) and base mounting. Line terminals may be configured top in/bottom out or bottom in/top out. It accepts A2-A4 fuses in the British Standard system and uses lug terminals 20 mm wide, tightened to 15 to 22 N·m. Rated operational voltage is 690 V AC; rated insulation voltage is 1000 V and rated impulse withstand voltage is 8 kV. Power loss is 4 W per pole at rated operating conditions. It conforms to IEC 60947-3. Handle and shaft are not included. Dimensions are 147 mm wide, 140 mm high, and 115 mm deep; net weight is 1.5 kg.
- OS125GB03N3P
ABB OS125GB03N3P fuse protector, 3+N pole, front-operated, base mounting. Rated current 125 A; rated operational voltage 690 V AC. Conventional free-air thermal current 125 A at 40 °C; conventional thermal current 125 A fully enclosed. Rated insulation voltage 1000 V; rated impulse withstand voltage 8 kV; rated conditional short-circuit current 80 kA at 690 V; short-time withstand current 5 kA rms for 1 s. Fuse size A2-A4, British Standard fuse system. Fourth pole is a detachable neutral link integrated into the mechanism. Lug terminals, 20 mm width, tightening torque 15 to 22 N·m. Power loss 4 W per pole at rated operating conditions. Pollution degree 3. Dimensions 147 x 140 x 115 mm; net weight 2.27 kg. Standards: IEC 60947-3.
- OS125GB03N3P-42
ABB OS125GB03N3P-42 fuse switch disconnector, 3+N poles, rated current 125 A. Rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 8 kV. Rated conditional short-circuit current 80 kA at 690 V. Conventional free-air thermal current 125 A at 40 °C; enclosed thermal current 125 A. Rated short-time withstand current 5 kA rms for 1 s. Power loss 4 W per pole at rated operating conditions. Fuse size A2-A4, British Standard fuse system. Fourth pole is a detachable neutral link integrated into the mechanism. Front-operated mechanism, left side, base mounting, lug terminals 20 mm, tightening torque 15 to 22 N·m. Dimensions 147 x 140 x 115 mm; net weight 2.35 kg. Pollution degree 3. Standards: IEC 60947-3.
- OS125GB03P
The ABB OS125GB03P is a 3-pole fuse switch disconnector with a rated current of 125 A in the main circuit and a rated operational voltage of 690 V AC. It uses British Standard fuses in sizes A2-A4 and accepts cable cross-sections from 2.5 to 25 mm² via lug terminals with a tightening torque of 15 to 22 N·m. Rated insulation voltage is 1000 V, rated impulse withstand voltage is 8 kV, and rated conditional short-circuit current is 80 kA at 690 V. It is front-operated with a pistol handle and shaft included, base mounting, and complies with IEC 60947-3. Dimensions are 147 mm wide, 140 mm high, and 115 mm deep, weighing 1.6 kg.
- OS125GB03P-42
ABB fuse protector, model OS125GB03P-42, is a 3-pole fuse switch disconnector for base mounting with front operation and a left-side 03 operating mechanism. It is rated 125 A at 690 V AC, with conventional free-air thermal current 125 A at 40 °C and fully enclosed thermal current 125 A. Rated insulation voltage is 1000 V, rated impulse withstand voltage 8 kV, and rated conditional short-circuit current 80 kA at 690 V. It accepts British Standard fuses in sizes A2-A4 and uses 20 mm lug terminals with tightening torque 15 to 22 N·m. Power loss is 4 W per pole at rated operating conditions. Dimensions are 146.5 mm wide, 172 mm high, and 114.5 mm deep; net weight 2.06 kg. Standards: IEC 60947-3.
- OS125GB04BBN1P
ABB OS125GB04BBN1P fuse switch disconnector, manufacturer identification 1SCA122597R1001. Four-pole, front-operated unit with base mounting, pistol handle and shaft included, and line terminals arranged back in, back out. Rated current 125 A in the main circuit; conventional free-air thermal current 125 A at 40 °C; conventional thermal current 125 A fully enclosed. Rated operational voltage 690 V AC, rated insulation voltage 1000 V, rated impulse withstand voltage 8 kV. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 5 kA rms for 1 s. Fuse system British Standard, fuse size A2-A4. Fourth pole left side, switched with solid link. Power loss 4 W per pole at rated operating conditions. Standards: IEC 60947-3.
- OS125GB04BBN2
ABB OS125GB04BBN2 fuse protector, order code 1SCA120784R1001. Four-pole, front-operated, base-mounting switch fuse with a fourth pole on the right side, switched with solid link. Rated current 125 A; rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 8 kV. Conventional free-air thermal current 125 A at 40 °C; conventional thermal current 125 A fully enclosed. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 5 kA rms for 1 s. Rated operational power AC-23A: 37 kW at 220–240 V, 55 kW at 400/415 V, 75 kW at 500 V, 110 kW at 690 V. Fuse size A2–A4, British Standard fuse system. Lug terminals, 20 mm wide, tightening torque 15–22 N·m. Pollution degree 3. IEC 60947-3. Dimensions 137 x 182 x 118 mm; 2.2 kg. Handle and shaft not included.