- AF38B-40-00-14
The ABB AF38B-40-00-14 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 101 mm deep, and 86 mm high, and weighs 0.41 kg. The main circuit is rated 690 V at 50/60 Hz, with a rated insulation voltage of 690 V according to IEC 60947-4-1 and 600 V according to UL/CSA, and a rated impulse withstand voltage of 6 kV. Rated operational current AC-3 is 22 A at 380/400 V and 60 °C, and rated operational power AC-3 is 11 kW at 400 V. Standards listed include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, and CSA C22.2 No. 60947-4-1.
- AF38B-40-00RT-14
The ABB AF38B-40-00RT-14 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. Its control circuit accepts 250 to 500 V at 50 or 60 Hz, and 250 to 500 V DC. The main circuit is rated 690 V, 50/60 Hz, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V to IEC 60947-4-1 and 600 V to UL/CSA. Conventional free-air thermal current is 55 A at 40 °C. AC-3 ratings include 22 A at 380/400 V and 11 kW at 400 V, 415 V, 440 V, and 500 V. Dimensions are 45 mm wide, 101 mm deep, and 86 mm high; weight is 0.39 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF38Z-22-00-20
ABB AF38Z-22-00-20 is a 4-pole AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It measures 45 mm wide, 101 mm deep, and 86 mm high, and weighs 0.4 kg. The main circuit is rated 690 V at 50/60 Hz. Per IEC 60947-4-1, conventional free-air thermal current is 55 A at 40 °C. AC-3 ratings include 22 A at 380/400 V and 11 kW at 400 V, 415 V, 440 V, and 500 V. Rated insulation voltage is 690 V per IEC 60947-4-1 and 600 V per UL/CSA. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.
- AF38Z-22-00-21
The ABB AF38Z-22-00-21 is an AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It measures 45 mm wide, 101 mm deep, and 86 mm high, and weighs 0.4 kg. The main circuit is rated 690 V at 50/60 Hz, with a rated impulse withstand voltage of 6 kV and a rated insulation voltage of 690 V according to IEC 60947-4-1 and 600 V according to UL/CSA. Conventional free-air thermal current is 55 A at 40 °C per IEC 60947-4-1. AC-3 rated operational power is 11 kW at 400 V, 415 V, 440 V, and 500 V, and 9 kW at 690 V. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, and CAN/CSA C22.2 No.60947-4-1.
- AF38Z-22-00-22
ABB AF38Z-22-00-22 is a 4-pole AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It measures 45 mm wide, 101 mm deep, and 86 mm high, and weighs 0.4 kg. The main circuit is rated 690 V, with a rated insulation voltage of 690 V according to IEC 60947-4-1 and 600 V according to UL/CSA, and a rated impulse withstand voltage of 6 kV. Rated operational current AC-3 is 22 A at 380/400 V and 60 °C, 20 A at 440 V and 60 °C, and 10.5 A at 690 V and 60 °C. Rated operational power AC-3 is 11 kW at 400 V, 415 V, 440 V, and 500 V, and 9 kW at 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.
- AF38Z-22-00-23
The ABB AF38Z-22-00-23 is a 4-pole AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It measures 45 mm wide, 101 mm deep, and 86 mm high, and weighs 0.4 kg. The main circuit is rated 690 V, with a rated insulation voltage of 690 V according to IEC 60947-4-1 and 600 V according to UL/CSA, and a rated impulse withstand voltage of 6 kV. Rated operational power in AC-3 is 11 kW at 400 V, 415 V, 440 V, and 500 V, and 9 kW at 690 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, and CAN/CSA C22.2 No.60947-4-1.
- AF38Z-22-00-30
ABB AF38Z-22-00-30 is an AC contactor with 2 normally open and 2 normally closed main contacts, and no auxiliary contacts. It is rated for a main circuit of 690 V at 50/60 Hz, with a rated insulation voltage of 690 V according to IEC 60947-4-1 and 600 V according to UL/CSA, and a rated impulse withstand voltage of 6 kV. AC-3 rated operational power is 11 kW at 400 V, 415 V, 440 V, and 500 V, and 9 kW at 690 V. Dimensions are 45 mm width, 121 mm depth, and 86 mm height, with a net weight of 0.53 kg. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 508, and CSA C22.2 No. 60947-4-1.
- AF38Z-30-00-20
ABB AF38Z-30-00-20 is a 3-pole AC contactor with 3 NO main contacts and no auxiliary contacts. It is rated 690 V AC main circuit, 50/60 Hz, with AC-3 ratings of 38 A at 415 V and 18.5 kW at 400 V, and AC-1 thermal current 50 A at 40 °C. Control circuit voltage is 12 to 20 V DC. Dimensions are 45 mm width, 86 mm depth, 86 mm height, 0.35 kg. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715 or on 2 x M4 screws. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1. Screw terminals, IP20.