- OS125GD22FP
The ABB OS125GD22FP is a base-mounted fuse protector with a switched fusible fourth pole. It accepts NH000 and NH00 fuses in the DIN system. Conventional free-air thermal current is 125 A at 40 °C; conventional thermal current in fully enclosed conditions is 125 A. Pollution degree 3. Dimensions are 183 mm wide, 140 mm high, and 130 mm deep; net weight is 2.6 kg. A pistol handle and shaft are included. Manufacturer ID 1SCA116732R1001.
- OS125GD22LR
The ABB OS125GD22LR is a 4-pole fuse switch disconnector for base mounting, with front-operated mechanism and line terminals left in, right out. It accepts NH000/NH00 DIN fuses; the fourth pole is switched-fusible. Rated insulation voltage is 1000 V, rated operational voltage 690 V AC, rated current 125 A, rated impulse withstand voltage 8 kV, and rated conditional short-circuit current 80 kA at 690 V. Rated operational current is 125 A at 500 V and 690 V for AC-21A, AC-22A, and AC-23A; rated operational power AC-23A is 55 kW at 400 V and 110 kW at 690 V. It conforms to IEC 60947-3. Dimensions are 277 mm wide, 150 mm high, and 156 mm deep; weight 2.9 kg. Handle and shaft are not included.
- OS125GD22LR-MNS
ABB fuse protector, model OS125GD22LR-MNS. Manufacturer ID 1SCA129777R1001. This is a four-pole fuse switch disconnector for base mounting, front operated, with lug terminals. It accepts NH000 and NH00 fuses in the DIN fuse system. Rated operational voltage of the main circuit is 690 V AC. Terminal tightening torque is 15 ... 22 N·m. Product net weight is 2.6 kg. It is classified under IEC 60947-3, ETIM 8 and ETIM 9 class EC001040, UNSPSC 39122233, and IGCC 5291. WEEE category 5, small equipment with no external dimension more than 50 cm.
- OS125GD22LRP
The ABB OS125GD22LRP is a four-pole fuse switch disconnector for base mounting, front operated, with line terminals left in and right out. It accepts NH000 and NH00 DIN fuses, and the fourth pole is a switched fusible pole. Rated values include 125 A main circuit current, 690 V AC operational voltage, 1000 V insulation voltage, 8 kV impulse withstand, and 80 kA conditional short-circuit current at 690 V. AC-23A operational power is 37 kW at 220 to 240 V, 55 kW at 400 V and 415 V, 75 kW at 500 V, and 110 kW at 690 V. It conforms to IEC 60947-3. Dimensions are 277 mm wide, 150 mm high, and 156 mm deep; net weight is 3.1 kg. A pistol handle and shaft are included.
- OS125GD22N1
ABB OS125GD22N1 fuse switch disconnector, manufacturer ID 1SCA116805R1001. Four-pole, front-operated, base-mounting unit with DIN fuse system for NH000/NH00 fuses. Rated current 125 A in the main circuit; conventional free-air thermal current 125 A at 40 °C; conventional thermal current 125 A fully enclosed. Rated operational voltage 690 V AC, rated insulation voltage 1000 V, rated impulse withstand voltage 8 kV. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 5 kA rms for 1 s. Power loss 4 W per pole at rated operating conditions. Lug terminals, 20 mm wide, tightening torque 15 to 22 N·m. Pollution degree 3. Dimensions 183 mm width, 140 mm height, 130 mm depth; net weight 2.4 kg. Standards: IEC 60947-3. Handle and shaft not included.
- OS125GD22N1P
The ABB OS125GD22N1P is a four-pole fuse switch disconnector for base mounting, front operated via the included pistol handle and shaft. It accepts NH000 and NH00 DIN fuses. Rated current is 125 A in the main circuit, with conventional free-air thermal current 125 A at 40 °C and conventional thermal current 125 A fully enclosed. Rated operational voltage is 690 V AC; rated insulation voltage is 1000 V and rated impulse withstand voltage is 8 kV. Rated conditional short-circuit current is 80 kA at 690 V, and rated short-time withstand current is 5 kA rms for 1 s. Power loss is 4 W per pole at rated operating conditions. It conforms to IEC 60947-3. Dimensions are 183 mm wide, 140 mm high, and 130 mm deep; net weight is 2.6 kg.
- OS125GD40F
ABB fuse protector, display model OS125GD40F, manufacturer ID 1SCA154758R1001. Four-pole fuse switch disconnector for DIN NH000/NH00 fuses, base mounting, front operated, with the fourth pole switched and fusible. Rated current 125 A; rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 8 kV. Conventional free-air thermal current 125 A at 40 °C; conventional thermal current 125 A fully enclosed. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 5 kA rms for 1 s. Power loss 4 W per pole at rated operating conditions. IP65 acc. to IEC 60529; pollution degree 3; IEC 60947-3. Dimensions 220 x 170 x 150 mm; 2.4 kg. Lug terminals, 20 mm; tightening torque 15 to 22 N·m. Handle and shaft not included.
- OS125GD40F-134
The ABB OS125GD40F-134 is a four-pole fuse protector for base mounting with front operation. It accepts NH000 and NH00 fuse links in the DIN fuse system and uses lug terminals. The main circuit is rated 690 V AC, and power loss is 4 W per pole at rated operating conditions. Terminal tightening torque is 15 to 22 N·m. The product is designed to IEC 60947-3 and weighs 2.4 kg. Manufacturer ID 1SCA159818R1001. ETIM 8 and ETIM 9 classify it as EC001040 fuse switch disconnector; UNSPSC 39122233 and IGCC 5291 also identify it as a fuse switch disconnector.