- CM-PAS.41S
The ABB CM-PAS.41S is a three-phase monitoring relay for phase failure detection, phase sequence monitoring, and phase unbalance detection. Its measuring and rated control supply voltage range is 300 to 500 V AC (L-L) at 50/60 Hz. The time range provides a 200 ms start-up delay and a tripping delay of 0 s or 0.1 to 30 s. Output is two changeover (SPDT) contacts with screw terminals. Rated operational currents are 4 A at 230 V AC-12, 3 A at 230 V AC-15, 4 A at 24 V DC-12, and 2 A at 24 V DC-13. Minimum switching capacity is 24 V, 10 mA. Dimensions are 22.5 mm wide, 85.6 mm high, and 103.7 mm deep; net weight is 0.132 kg. Housing protection is IP50, terminals IP20.
- CM-PBE
The ABB CM-PBE is a three-phase monitoring relay for phase failure detection, specifically phase loss. Its measuring and rated control supply voltage range is 380 to 440 V AC (L-L) at 50/60 Hz. The time range provides a 500 ms start-up delay and 150 ms tripping delay. Output is one normally open contact. The relay measures 22.5 mm wide, 78 mm high, and 78.5 mm deep, and weighs 0.066 kg. It uses screw terminals and has a rated operational current of 4 A at 230 V AC-12, 3 A at 230 V AC-15, 4 A at 24 V DC-12, and 2 A at 24 V DC-13. Rated impulse withstand voltage is 4 kV, rated insulation voltage is 400 V, overvoltage category is III, and protection is IP50 housing and IP20 terminals. Manufacturer ID: 1SVR550882R9500.
- CM-PFE
The ABB CM-PFE is a three-phase monitoring relay for phase failure and phase sequence, identified by manufacturer ID 1SVR550824R9100. It is powered by the measuring circuit and provides one changeover (SPDT) output contact. The measuring range is 208 to 440 V AC (L-L) at 50/60 Hz, with a 500 ms start-up delay and 500 ms tripping delay. Output ratings include 4 A at 230 V AC-12, 3 A at 230 V AC-15, 4 A at 24 V DC-12, and 2 A at 24 V DC-13. The input circuit has a rated impulse withstand voltage of 6 kV and a rated insulation voltage of 600 V between input and output circuits. Housing protection is IP50 and terminals are IP20. Dimensions are 22.5 mm wide, 78 mm high, and 78.5 mm deep; net weight is 0.068 kg.
- CM-PFE.2
The ABB CM-PFE.2 intermediate relay (manufacturer ID 1SVR550826R9100) monitors phase failure and phase sequence in three-phase networks. Its measuring and rated control supply voltage range is 200 to 500 V AC (L-L) at 50/60 Hz. Start-up and tripping delays are each 500 ms. The output is one changeover (SPDT) contact, rated 4 A at 230 V AC-12, 3 A at 230 V AC-15, 4 A at 24 V DC-12, and 2 A at 24 V DC-13. The input circuit has a rated impulse withstand voltage of 6 kV and a rated insulation voltage of 600 V to the output circuit. Screw terminals are used. Dimensions are 22.5 mm wide, 78 mm high, and 78.5 mm deep; net weight is 0.067 kg. Housing protection is IP50, terminals IP20, overvoltage category III, pollution degree 3.
- CM-PFS.S
The ABB CM-PFS.S is a three-phase monitoring relay, manufacturer ID 1SVR730824R9300. It performs phase failure detection and phase sequence monitoring over a measuring range of 200 to 500 V AC (L-L), with a rated control supply voltage of 200 to 500 V AC (L-L) and rated frequency of 50/60 Hz. A 500 ms start-up delay is specified. Output is two changeover (SPDT) contacts. Rated operational currents are 4 A at 230 V AC-12, 3 A at 230 V AC-15, 4 A at 24 V DC-12, and 2 A at 24 V DC-13; minimum switching capacity is 24 V, 10 mA. The relay measures 22.5 mm wide, 85.6 mm high, and 103.7 mm deep, weighs 0.127 kg, uses screw terminals, and has housing protection IP50 and terminal protection IP20.
- CM-PSS.31P
ABB CM-PSS.31P is an industrial catalog item. Key specifications include Manufacturer: ABB, Type of module: voltage monitoring relay, Controlled parameter1: too low voltage, and Controlled parameter: overvoltage. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- CM-PSS.31S
The ABB CM-PSS.31S intermediate relay (manufacturer ID 1SVR730784R2300) monitors three-phase mains for phase failure, phase sequence, and over- and undervoltage. Its measuring range is 342 to 418 V AC (L-L) at a rated control supply voltage of 380 V AC (L-L) and 50/60 Hz. The time range includes a 200 ms start-up delay and a 0 s or 0.1 to 30 s tripping delay, selectable ON or OFF. Output is two changeover (SPDT) contacts with screw terminals. The unit measures 22.5 mm wide, 85.6 mm high, and 103.7 mm deep, and weighs 0.132 kg. Housing protection is IP50 and terminal protection is IP20.
- CM-PSS.41P
ABB CM-PSS.41P is an industrial catalog item. Key specifications include Manufacturer: ABB, Type of module: voltage monitoring relay, Controlled parameter1: too low voltage, and Controlled parameter: overvoltage. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.