- OS125GF02P
ABB fuse switch disconnector, model OS125GF02P, manufacturer ID 1SCA116727R1001. Two-pole, front-operated unit with pistol handle and shaft included, base mounting, and lug terminals 20 mm wide. Main circuit rated current 125 A; rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 8 kV. Conventional free-air thermal current 125 A at 40 °C; conventional thermal current 125 A fully enclosed. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 5 kA rms for 1 s. Rated operational power AC-23A: 37 kW at 220–240 V, 55 kW at 400 V and 415 V, 75 kW at 500 V, 110 kW at 690 V. Fuse size 22x58, NFC system. Power loss 4 W per pole at rated operating conditions. Pollution degree 3. Tightening torque 15–22 N·m. Dimensions 112 x 140 x 130 mm; net weight 1.2 kg. Standards: IEC 60947-3.
- OS125GF03
ABB OS125GF03 fuse switch disconnector, manufacturer ID 1SCA115601R1001, is a three-pole, front-operated device for base mounting. It accepts 22x58 fuses in the NFC system and has lug terminals 20 mm wide, tightened to 15 to 22 N·m. Rated values include 125 A main circuit current, 690 V AC operating voltage, 1000 V insulation voltage, and 8 kV impulse withstand voltage. Conventional free-air thermal current is 125 A at 40 °C; enclosed thermal current is 125 A. Rated conditional short-circuit current is 80 kA at 690 V, and short-time withstand current is 5 kA rms for 1 s. Power loss is 4 W per pole at rated operating conditions. Pollution degree 3. Dimensions are 147 mm wide, 140 mm high, and 130 mm deep; net weight 1.84 kg. Cable cross-section is 2.5 to 25 mm². Standards: IEC 60947-3. Handle and shaft are not included.
- OS125GF03P
ABB OS125GF03P fuse switch disconnector, manufacturer ID 1SCA115602R1001. Three-pole, front-operated unit with pistol handle and shaft included, base mounting, and lug terminals 20 mm wide. Main circuit rated current 125 A; rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 8 kV. Conventional free-air thermal current 125 A at 40 °C; conventional thermal current 125 A fully enclosed. Rated conditional short-circuit current 80 kA at 690 V. Rated short-time withstand current 5 kA rms for 1 s. Accepts 22x58 mm fuses, NFC fuse system. Cable cross-section 2.5 to 25 mm². Power loss 4 W per pole at rated operating conditions. Tightening torque 15 to 22 N·m. Pollution degree 3. Dimensions 147 x 140 x 130 mm; net weight 2.03 kg. Conforms to IEC 60947-3.
- OS125GF04F
ABB OS125GF04F fuse switch disconnector, four-pole, front-operated, base mounting. Rated current 125 A in the main circuit; conventional free-air thermal current 125 A at 40 °C; conventional thermal current 125 A fully enclosed. Rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 8 kV. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 5 kA rms for 1 s. Rated operational power AC-23A: 37 kW at 220–240 V, 55 kW at 400 V and 415 V, 75 kW at 500 V, 110 kW at 690 V. Fuse size 22x58, NFC system. Cable cross-section 2.5 to 25 mm²; lug terminals 20 mm wide; tightening torque 15 to 22 N·m. Pollution degree 3. Standards: IEC 60947-3. Handle and shaft not included. Dimensions 182 x 140 x 130 mm; weight 1.8 kg.
- OS125GF04FP
ABB OS125GF04FP fuse switch disconnector, four-pole, front-operated, base mounting, with pistol handle and shaft included. Rated current 125 A in the main circuit; conventional free-air thermal current 125 A at 40 °C and conventional thermal current 125 A fully enclosed. Rated operational voltage 690 V AC, rated insulation voltage 1000 V, rated impulse withstand voltage 8 kV, and rated conditional short-circuit current 80 kA at 690 V. Rated short-time withstand current 5 kA rms for 1 s. Power loss 4 W per pole at rated operating conditions. Fuse size 22x58, NFC fuse system. Cable cross-section 2.5 to 25 mm²; lug terminals 20 mm wide; tightening torque 15 to 22 N·m. Pollution degree 3. Standards: IEC 60947-3. Net dimensions 182 mm x 140 mm x 130 mm; net weight 2.0 kg.
- OS125GF04N1
ABB OS125GF04N1 fuse switch disconnector, four-pole, front-operated, base mounting. Rated current 125 A; rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 8 kV. Conventional free-air thermal current 125 A at 40 °C; conventional thermal current 125 A fully enclosed. Rated conditional short-circuit current 80 kA at 690 V. Rated short-time withstand current 5 kA rms for 1 s. Fuse size 22x58, NFC fuse system. Fourth pole is switched with solid link, left side. Lug terminals, 20 mm terminal width, tightening torque 15 to 22 N·m. Power loss 4 W per pole at rated operating conditions. Pollution degree 3. Standards: IEC 60947-3. Handle and shaft not included. Dimensions 182 x 140 x 130 mm; net weight 2.36 kg.
- OS125GF04N1P
ABB fuse protector, model OS125GF04N1P, manufacturer ID 1SCA115888R1001. Four-pole, front-operated fuse switch disconnector for base mounting, with the fourth pole on the left side, switched with solid link. Rated current 125 A; conventional free-air thermal current 125 A at 40 °C; conventional thermal current 125 A fully enclosed. Rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 8 kV; rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 5 kA rms for 1 s. Fuse size 22x58, NFC fuse system. Lug terminals, 20 mm wide, tightening torque 15 to 22 N·m. Power loss 4 W per pole at rated operating conditions. Pollution degree 3. Standards: IEC 60947-3. Dimensions 182 x 140 x 130 mm; net weight 2.55 kg. Pistol handle and shaft included.
- OS125GF11
The ABB OS125GF11 is a two-pole fuse protector for base mounting, front operated, with line terminals configurable as top in - bottom out or bottom in - top out. It accepts 22x58 fuses in the NFC system and uses lug terminals 20 mm wide, tightened to 15 ... 22 N·m. Rated current is 125 A in the main circuit; conventional free-air thermal current is 125 A at 40 °C, and conventional thermal current fully enclosed is 125 A. Rated operational voltage is 690 V AC, rated insulation voltage 1000 V, rated impulse withstand voltage 8 kV, and rated conditional short-circuit current 80 kA at 690 V. Power loss is 4 W per pole at rated operating conditions. Pollution degree 3. Standards: IEC 60947-3. Handle and shaft are not included. Dimensions are 112 mm width, 140 mm height, 130 mm depth; net weight 1.2 kg.