- OS63GDSL40FMNS
ABB OS63GDSL40FMNS is a four-pole fuse switch disconnector for base mounting with side operation. It accepts NH000 DIN fuse links and uses screw terminals with a connecting capacity of 2.5 to 25 mm² for both stranded and flexible conductors. Tightening torque is 3 N·m to 4 N·m. The main circuit is rated 690 V AC, with power loss of 4 W per pole at rated operating conditions. It is designed to IEC 60947-3 and weighs 1.2 kg. Manufacturer ID: 1SCA124601R1001.
- OS63GDSL40N1MNS
The ABB OS63GDSL40N1MNS is a four-pole, side-operated fuse switch disconnector for base mounting, identified by manufacturer ID 1SCA124599R1001. It accepts NH000 fuses in the DIN system and uses screw terminals with a tightening torque of 3 N·m to 4 N·m. Connecting capacity is 2.5 to 25 mm² for both stranded and flexible conductors. The main circuit is rated 690 V AC, with power loss of 4 W per pole at rated operating conditions. Dimensions are 197 mm wide, 192 mm high, and 147 mm deep; net weight is 1.18 kg. It is designed to IEC 60947-3 and classified as ETIM EC001040, fuse switch disconnector.
- OS63GDT12P/B20
ABB fuse protector, model OS63GDT12P/B20. Manufacturer ID 1SCA128303R1001. Three-pole fuse switch disconnector for base mounting, front operated, with screw terminals. Rated operational voltage of the main circuit is 690 V AC. Fuse size NH000, DIN fuse system. Connecting capacity: stranded 2.5 to 25 mm² and flexible 2.5 to 25 mm². Tightening torque 3 N·m to 4 N·m. Power loss at rated operating conditions is 4 W per pole. Dimensions: 630 mm width, 400 mm height, 300 mm depth; net weight 24.54 kg. Conforms to IEC 60947-3. ETIM class EC001040 fuse switch disconnector.
- OS800B02P
The ABB OS800B02P is a two-pole fuse switch disconnector for base mounting with front operation. It uses a British Standard fuse system, sizes C1-C3, and includes a pistol handle and shaft. Rated current is 800 A in the main circuit, with conventional free-air thermal current 800 A at 40 °C and fully enclosed thermal current 720 A. Rated operational voltage is 690 V AC; rated insulation voltage is 1000 V and rated impulse withstand voltage is 12 kV. Rated conditional short-circuit current is 80 kA at 690 V, and rated short-time withstand current is 18 kA rms for 1 s. Power loss is 75 W per pole at rated operating conditions. Terminals are lug type, 39 mm wide, tightened to 50 to 75 N·m. Pollution degree 3. Standards: IEC 60947-3.
- OS800B03
ABB OS800B03 fuse switch disconnector, 3-pole, front-operated, base mounting. Rated current 800 A; rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Conventional free-air thermal current 800 A at 40 °C; conventional thermal current 720 A fully enclosed. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 18 kA rms for 1 s. Power loss 75 W per pole at rated operating conditions. Fuse system British Standard, fuse size C1-C3. Lug terminals, 39 mm terminal width, tightening torque 50 to 75 N·m. Pollution degree 3. Dimensions 343 mm width, 306 mm height, 233 mm depth; net weight 14.194 kg. Standards: IEC 60947-3. Handle and shaft not included.
- OS800B03K
ABB fuse protector, model OS800B03K, manufacturer ID 1SCA108713R1001. Three-pole, front-operated fusible switch disconnector for base mounting, rated 800 A main circuit at 690 V AC, with a direct-mounted handle included. Conventional free-air thermal current Ith is 800 A at 40 °C; fully enclosed thermal current Ithe is 720 A. Rated insulation voltage Ui is 1000 V and rated impulse withstand voltage Uimp is 12 kV. Rated conditional short-circuit current Inc is 80 kA at 690 V; rated short-time withstand current Icw is 18 kA rms for 1 s. Fuse system is British Standard, fuse size C1-C3. Lug terminals, 39 mm wide, tightening torque 50 to 75 N·m. Cable cross-section 2.5 to 25 mm². Pollution degree 3. Power loss 75 W per pole at rated operating conditions. Standards: IEC 60947-3. Dimensions 343 x 306 x 233 mm; net weight 15.014 kg.
- OS800B03N3
The ABB OS800B03N3 is a base-mounting fuse switch disconnector with 3+N poles and a detachable neutral link integrated into the mechanism. It is rated 800 A in the main circuit at 690 V AC, with a conventional free-air thermal current (Ith) of 800 A at 40 °C and a fully enclosed thermal current (Ithe) of 720 A. Rated insulation voltage is 1000 V and rated impulse withstand voltage is 12 kV. Rated conditional short-circuit current (Inc) is 80 kA at 690 V; rated short-time withstand current (Icw) is 18 kA rms for 1 s. It uses British Standard C1-C3 fuses, lug terminals of 39 mm width, and tightening torque of 50 to 75 N·m. It conforms to IEC 60947-3. Handle and shaft are not included.
- OS800B03N3P
ABB OS800B03N3P fuse protector, manufacturer ID 1SCA100861R1001. Front-operated, base-mounted switch fuse with three poles and a detachable neutral link integrated into the mechanism. Rated current 800 A; conventional free-air thermal current 800 A at 40 °C; conventional thermal current 720 A fully enclosed. Rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Rated conditional short-circuit current 80 kA at 690 V. Rated short-time withstand current 18 kA rms for 1 s. Power loss 75 W per pole at rated operating conditions. Fuse system British Standard, fuse size C1-C3. Lug terminals, 39 mm terminal width, tightening torque 50 to 75 N·m. Pollution degree 3. Standards: IEC 60947-3. Dimensions 343 mm width, 306 mm height, 233 mm depth; net weight 13.5 kg.