- OS250D13N2P
The ABB OS250D13N2P is a four-pole front-operated fuse switch disconnector for base mounting, with the fourth pole on the right side, switched with a solid link. It accepts NH0 and NH1 fuses in the DIN fuse system and is rated 250 A at 690 V AC. Rated insulation voltage is 1000 V, rated impulse withstand voltage is 12 kV, and rated conditional short-circuit current is 80 kA at 690 V. Rated short-time withstand current is 8 kA rms for 1 s. Power loss is 13 W per pole at rated operating conditions. Terminals are lug type, 25 mm wide, tightened to 30 to 44 N·m. Dimensions are 260 mm width, 199 mm height, and 154 mm depth; net weight is 4.8 kg. It conforms to IEC 60947-3.
- OS250D20
ABB OS250D20 fuse switch disconnector, manufacturer ID 1SCA022760R0250. Two-pole, front-operated, base-mounting unit with lug terminals, 25 mm terminal width, and 30 to 44 N·m tightening torque. Rated current 250 A in the main circuit; conventional free-air thermal current 250 A at 40 °C; conventional thermal current 250 A fully enclosed. Rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV; rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 8 kA rms for 1 s. Power loss 13 W per pole at rated operating conditions. Accepts NH0 and NH1 DIN fuses. Pollution degree 3. IEC 60947-3. Handle and shaft not included. Dimensions 154 mm wide, 199 mm high, 154 mm deep; net weight 2.6 kg.
- OS250D20K
ABB OS250D20K fuse protector, identified by manufacturer ID 1SCA144497R1001. It is a two-pole, front-operated fuse switch disconnector for base mounting with lug terminals. The main circuit is rated 690 V AC, and it accepts NH0 and NH1 fuse sizes in the DIN fuse system. Power loss is 13 W per pole at rated operating conditions. Terminal tightening torque is 30 to 44 N·m. The device conforms to IEC 60947-3. Net dimensions are 310 mm width, 270 mm height, and 200 mm depth, with a net weight of 2.5 kg. Classification codes include ETIM EC001040, UNSPSC 39122233, and IGCC 5291.
- OS250D21LR
ABB OS250D21LR fuse protector, manufacturer ID 1SCA022852R8330. Three-pole, front-operated fuse switch disconnector for base mounting with lug terminals, 25 mm terminal width, and tightening torque 30 to 44 N·m. Rated current 250 A in the main circuit; conventional free-air thermal current 250 A at 40 °C; conventional thermal current 315 A fully enclosed. Rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 8 kA rms for 1 s. Accepts NH0 and NH1 DIN fuses. Power loss 17 W per pole at rated operating conditions. Pollution degree 3. Dimensions 297 mm width, 150 mm height, 218 mm depth; 5.2 kg. Standards: IEC 60947-3. Handle and shaft not included.
- OS250D21LRP
ABB OS250D21LRP fuse switch disconnector, manufacturer ID 1SCA022852R8500. Three-pole, front-operated, base-mounting unit with pistol handle and shaft included, accepting NH0 and NH1 DIN fuse sizes. Rated current 250 A in the main circuit; conventional free-air thermal current 250 A at 40 °C and 250 A fully enclosed. Rated operational voltage 690 V AC, rated insulation voltage 1000 V, rated impulse withstand voltage 12 kV, rated conditional short-circuit current 80 kA at 690 V, and short-time withstand current 8 kA rms for 1 s. Power loss 17 W per pole at rated operating conditions. Lug terminals, 25 mm wide, tightened to 30 to 44 N·m. Pollution degree 3. Standards: IEC 60947-3. Dimensions 353 mm width, 150 mm height, 234 mm depth; net weight 6.1 kg.
- OS250D21P
The ABB OS250D21P is a two-pole fuse protector with base mounting and front operation. It accepts NH0 and NH1 DIN fuse sizes and includes a pistol handle and shaft. Rated insulation voltage is 1000 V, rated impulse withstand voltage is 12 kV, and rated operational voltage for the main circuit is 690 V AC. Rated current is 250 A. Conventional free-air thermal current is 250 A at 40 °C; conventional thermal current fully enclosed is 250 A. Rated conditional short-circuit current is 80 kA at 690 V. Rated short-time withstand current is 8 kA rms for 1 s. Power loss is 13 W per pole at rated operating conditions. Terminals are lug type, 25 mm wide, tightened to 30 to 44 N·m. Pollution degree 3. Complies with IEC 60947-3. Dimensions are 206 mm wide, 199 mm high, 154 mm deep; net weight 4.1 kg.
- OS250D22BBN2
ABB OS250D22BBN2 is a four-pole fuse switch disconnector for base mounting, front operated, with line terminals positioned back in and back out. It accepts NH0 and NH1 DIN fuse sizes. The main circuit is rated 250 A at 690 V AC, with rated insulation voltage 1000 V, rated impulse withstand voltage 12 kV, and rated conditional short-circuit current 80 kA at 690 V. Conventional free-air thermal current is 250 A at 40 °C; enclosed thermal current is 250 A. Power loss is 13 W per pole at rated operating conditions. Short-time withstand current is 8 kA rms for 1 s. The fourth pole is switched with a solid link on the right side. Lug terminals are 25 mm wide; tightening torque is 30 to 44 N·m. Standards: IEC 60947-3. Handle and shaft are not included. Dimensions: 260 mm width, 193 mm height, 189 mm depth; 4.31 kg.
- OS250D22F
ABB OS250D22F fuse switch disconnector, 4-pole, base mounting, front operated. Rated current 250 A; rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Conventional free-air thermal current 250 A at 40 °C; fully enclosed conventional thermal current 250 A. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 8 kA rms for 1 s. Power loss 13 W per pole at rated operating conditions. DIN fuse system, fuse sizes NH0 and NH1. Fourth pole switched-fusible. Lug terminals, 25 mm terminal width, tightening torque 30 to 44 N·m. Pollution degree 3. Standards: IEC 60947-3. Handle and shaft not included. Net dimensions 260 mm width, 199 mm height, 154 mm depth; net weight 4.7 kg.