- AF750-30-11-70 CT19001
The ABB AF750-30-11-70 CT19001 is a 3-pole, non-reversing AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. The main circuit is rated 1000 V and 50/60 Hz. Conventional free-air thermal current is 1050 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 1000 A at 1000 V and 40 °C, and 1050 A at 690 V and 40 °C. Rated insulation voltage is 1000 V per IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V per UL/CSA. Rated impulse withstand voltage is 8 kV. Mechanical durability is 3 million operations. Dimensions are 210 mm wide, 242 mm deep, and 283 mm high; net weight is 13.6 kg.
- AF750-30-11-71
The ABB AF750-30-11-71 is a non-reversing, 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. The main circuit is rated 1000 V at 50/60 Hz, with conventional free-air thermal current 1050 A according to IEC 60947-4-1 at 40 °C. AC-3 rated operational current is 750 A at 415 V, 440 V, 500 V, and 380/400 V at 55 °C, and 650 A at 690 V at 55 °C. Rated control circuit voltage is 250 to 500 V for 50 Hz, 60 Hz, and DC operation. Dimensions are 210 mm wide, 242 mm deep, and 283 mm high, with a net weight of 13.6 kg.
- AF750-30-22 100-250V
Product identification: ABB AF750-30-22 100-250V. The ABB AF750-30-22 is a 3-pole AC contactor with three normally open main contacts and four pre-mounted auxiliary contacts (2 NO, 2 NC). The control circuit voltage is 100 to 250 V at 50 Hz. Main circuit rated operational voltage is 1000 V. Rated operational current AC-3 is 750 A at 415 V, 440 V, 500 V, and 380/400 V at 55 °C, 650 A at 690 V, and 300 A at 1000 V. Rated operational power AC-3 is 400 kW at 380/400 V and 1000 V, 425 kW at 415 V, 450 kW at 440 V, 520 kW at 500 V, and 600 kW at 690 V. Dimensions are 210 mm wide, 242 mm deep, and 283 mm high, with a net weight of 13.6 kg. Mechanical durability is 3 million operations.
- AF750-30-22-68
The ABB AF750-30-22-68 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 210 mm wide, 242 mm deep, and 283 mm high, and weighs 13.6 kg. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 1050 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 750 A at 415 V and 55 °C, and rated operational power AC-3 is 425 kW at 415 V. Short-circuit protection uses gG type fuses rated 1000 A. Maximum electrical switching frequency is 300 cycles per hour in AC-1 and AC-3, and 60 cycles per hour in AC-2/AC-4.
- AF750-30-22-69
The ABB AF750-30-22-69 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It is rated for a main circuit of 1000 V at 50/60 Hz. Conventional free-air thermal current is 1050 A according to IEC 60947-4-1 for open contactors at 40 °C. AC-3 rated operational power includes 400 kW at 380/400 V, 425 kW at 415 V, 450 kW at 440 V, 520 kW at 500 V, 600 kW at 690 V, and 400 kW at 1000 V. Dimensions are 210 mm wide, 242 mm deep, and 283 mm high, with a net weight of 13.6 kg.
- AF750-30-22-70
The ABB AF750-30-22-70 is a three-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. The control circuit accepts 100 to 250 V at 50 Hz, 100 to 250 V at 60 Hz, and 100 to 250 V DC. Rated operational voltage for the main circuit is 1000 V at 50/60 Hz, with a rated impulse withstand voltage of 8 kV. AC-3 rated operational power includes 400 kW at 380/400 V and 450 kW at 440 V. Dimensions are 210 mm wide, 242 mm deep, and 283 mm high, weighing 13.6 kg. Main terminals are bars; main terminals are IP00 and coil terminals are IP20.
- AF750-30-22-70 CT19001
The ABB AF750-30-22-70 CT19001 is a 3-pole AC contactor, manufacturer ID 1SFL637033R7022. It has 3 main contacts (NO) and 2 auxiliary contacts each NO and NC. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 1050 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 1000 A at 1000 V and 40 °C, 875 A at 55 °C, and 720 A at 70 °C. Rated insulation voltage is 1000 V per IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V per UL/CSA. Rated impulse withstand voltage is 8 kV. Mechanical durability is 3 million operations. Dimensions are 210 mm wide, 242 mm deep, and 283 mm high, weighing 13.6 kg.
- AF750-30-22-71
The ABB AF750-30-22-71 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 210 mm wide, 242 mm deep, and 283 mm high, and weighs 13.6 kg. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 1050 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 750 A at 415 V, 440 V, 500 V, and 380/400 V at 55 °C, and 650 A at 690 V at 55 °C. Rated operational power AC-3 includes 400 kW at 380/400 V and 600 kW at 690 V. Short-circuit protection uses gG type fuses rated 1000 A.