- OS800B04N2
ABB OS800B04N2 fuse protector, a four-pole fuse switch disconnector for base mounting with front operation. Main circuit rated current is 800 A at a rated operational voltage of 690 V AC. Conventional free-air thermal current is 800 A at 40 °C; fully enclosed conventional thermal current is 720 A. Rated insulation voltage is 1000 V, rated impulse withstand voltage is 12 kV, and rated conditional short-circuit current is 80 kA at 690 V. It accepts British Standard fuses in sizes C1-C3 and uses lug terminals with 39 mm terminal width and 50 to 75 N·m tightening torque. The fourth pole is switched with a solid link, right side. Standards: IEC 60947-3. Handle and shaft are not included. Dimensions are 431 mm wide, 306 mm high, and 233 mm deep; net weight is 18.464 kg.
- OS800B04N2P
The ABB OS800B04N2P is a 4-pole fuse switch disconnector with a British Standard C1-C3 fuse system. The main circuit is rated 800 A at 690 V AC, with a rated insulation voltage of 1000 V and a rated impulse withstand voltage of 12 kV. Conventional free-air thermal current is 800 A at 40 °C; fully enclosed thermal current is 720 A. Rated conditional short-circuit current is 80 kA at 690 V, and rated short-time withstand current is 18 kA rms for 1 s. The fourth pole is switched with a solid link, mounted on the right side. It is front operated with a pistol handle and shaft included, base mounting, and lug terminals of 39 mm width. Tightening torque is 50 to 75 N·m. Standards: IEC 60947-3.
- OS800B12P
The ABB OS800B12P is a three-pole fuse protector with a British Standard fuse system, accepting C1-C3 fuse sizes. It is rated 800 A in the main circuit and 690 V AC, with a rated insulation voltage of 1000 V and a rated impulse withstand voltage of 12 kV. Conventional free-air thermal current is 800 A at 40 °C; enclosed thermal current is 720 A. Rated conditional short-circuit current is 80 kA at 690 V, and short-time withstand current is 18 kA rms for 1 s. Power loss is 75 W per pole at rated operating conditions. It is front-operated, base-mounted, and supplied with a pistol handle and shaft. Terminals are lug type, 39 mm wide, tightened to 50 to 75 N·m. Standards: IEC 60947-3. Dimensions: 341 mm width, 306 mm height, 233 mm depth; 13.5 kg.
- OS800B13N1P
ABB OS800B13N1P fuse switch disconnector, four-pole, front-operated, base mounting, with pistol handle and shaft included. Main circuit rated current 800 A at rated operational voltage 690 V AC. Conventional free-air thermal current 800 A at 40 °C; fully enclosed conventional thermal current 720 A. Rated insulation voltage 1000 V, rated impulse withstand voltage 12 kV, rated conditional short-circuit current 80 kA at 690 V, and rated short-time withstand current 18 kA rms for 1 s. Power loss 75 W per pole at rated operating conditions. Fuse size C1-C3, British Standard fuse system. Lug terminals, 39 mm terminal width, tightening torque 50 to 75 N·m. Pollution degree 3. Dimensions 429 mm width, 306 mm height, 233 mm depth; net weight 18.964 kg. Standards: IEC 60947-3.
- OS800B22N1P
The ABB OS800B22N1P is a four-pole, front-operated fuse switch disconnector for base mounting, with the fourth pole on the left side switched via a solid link. It uses British Standard C1-C3 fuse systems and lug terminals 39 mm wide, tightened to 50 to 75 N·m. Rated current is 800 A for the main circuit, with conventional free-air thermal current 800 A at 40 °C and fully enclosed thermal current 720 A. Rated operational voltage is 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Rated conditional short-circuit current is 80 kA at 690 V, and short-time withstand current is 18 kA rms for 1 s. It conforms to IEC 60947-3. Pollution degree 3. Dimensions: 429 mm width, 306 mm height, 233 mm depth; net weight 18.964 kg.
- OS800B22N2P
The ABB OS800B22N2P is a 4-pole front-operated fuse switch disconnector for base mounting, with the fourth pole on the right side as a switched pole with solid link. It uses British Standard fuse system fuses in sizes C1-C3 and lug terminals 39 mm wide, tightened to 50 to 75 N·m. The main circuit is rated 800 A at 690 V AC, with conventional free-air thermal current 800 A at 40 °C and fully enclosed thermal current 720 A. Rated insulation voltage is 1000 V, rated impulse withstand voltage 12 kV, and rated conditional short-circuit current 80 kA at 690 V. It conforms to IEC 60947-3. A pistol handle and shaft are included. Net dimensions are 429 mm wide, 306 mm high, and 233 mm deep; net weight is 16.4 kg.
- OS800B30P
ABB fuse protector, model OS800B30P, manufacturer ID 1SCA022837R3200. This is a three-pole, front-operated fuse switch disconnector for base mounting, using British Standard fuse system sizes C1-C3. Main circuit rated current is 800 A at a rated operational voltage of 690 V AC; rated insulation voltage is 1000 V and rated impulse withstand voltage is 12 kV. Conventional free-air thermal current is 800 A at 40 °C, and conventional thermal current fully enclosed is 720 A. Rated conditional short-circuit current is 80 kA at 690 V. Dimensions are 343 mm width, 306 mm height, 233 mm depth, 13.6 kg net weight. Lug terminals, 39 mm terminal width, tightening torque 50 to 75 N·m. Standards: IEC 60947-3.
- OS800B40N2P
The ABB OS800B40N2P is a four-pole fuse switch disconnector with a rated current of 800 A in the main circuit and a rated operational voltage of 690 V AC. It uses British Standard fuse system C1-C3 fuses and is front operated via a pistol handle and shaft, base mounted, with lug terminals of 39 mm width and tightening torque of 50 to 75 N·m. The fourth pole is on the right side, switched with a solid link. Conventional free-air thermal current is 800 A at 40 °C; fully enclosed thermal current is 720 A. Rated conditional short-circuit current is 80 kA at 690 V, rated short-time withstand current is 18 kA rms for 1 s, rated impulse withstand voltage is 12 kV, and rated insulation voltage is 1000 V. It conforms to IEC 60947-3 and has pollution degree 3.