- OS63D21
ABB OS63D21 is an industrial catalog item. Key specifications include ABB Type Designation: 3-nap. 63A 690V AC-22A DIN, Frame Size: Spare_Parts, Gross Weight: 1.44 kg, and Made To Order: No. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- OS63GB02
ABB OS63GB02 fuse switch disconnector, 2-pole, front-operated, base mounting. Rated current 63 A; rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Conventional free-air thermal current 63 A at 40 °C; conventional thermal current 63 A fully enclosed. Rated conditional short-circuit current 80 kA at 690 V. Rated short-time withstand current 2.5 kA rms for 1 s. Rated operational power AC-23A: 18.5 kW at 220–240 V, 30 kW at 400 V and 415 V, 37 kW at 500 V, 55 kW at 690 V. Fuse system British Standard, fuse size A2-A3. Screw terminals accept 2.5–25 mm²; tightening torque 3 N·m or 4 N·m; stripping length 12 mm. Pollution degree 3. Standards: IEC 60947-3. Handle and shaft not included. Dimensions 88 x 112 x 109 mm; 0.74 kg.
- OS63GB02P
ABB OS63GB02P fuse protector, order code 1SCA116854R1001. Two-pole front-operated fuse switch disconnector for base mounting with pistol handle and shaft included. Rated current 63 A; rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV; pollution degree 3. Conventional free-air thermal current 63 A at 40 °C; enclosed thermal current 63 A. Rated conditional short-circuit current 80 kA at 690 V; short-time withstand current 2.5 kA rms for 1 s. AC-23A operational power 30 kW at 400 V and 55 kW at 690 V. Fuse size A2-A3, British Standard system. Screw terminals accept 2.5 to 25 mm²; tightening torque 3 to 4 N·m; stripping length 12 mm. Standards: IEC 60947-3. Dimensions 88 x 112 x 109 mm; 0.93 kg.
- OS63GB03
The ABB OS63GB03 is a 3-pole fuse switch disconnector for base mounting, front operated, with the switch mechanism on the left side. It accepts A2-A3 fuses in the British Standard fuse system. Rated current is 63 A in the main circuit, with conventional free-air thermal current 63 A at 40 °C and conventional thermal current 63 A fully enclosed. Rated operational voltage is 690 V AC; rated insulation voltage is 1000 V and rated impulse withstand voltage is 12 kV. Rated conditional short-circuit current is 80 kA at 690 V, and rated short-time withstand current is 2.5 kA rms for 1 s. Screw terminals accept stranded or flexible cable from 2.5 to 25 mm². Dimensions are 112 mm wide, 112 mm high, and 109 mm deep; net weight is 0.99 kg. Standards: IEC 60947-3. Handle and shaft are not included.
- OS63GB03K
The ABB OS63GB03K is a 3-pole front-operated fuse switch disconnector for base mounting, with a direct-mounted handle included. It is rated 63 A and 690 V AC in the main circuit, with a rated insulation voltage of 1000 V and a rated impulse withstand voltage of 12 kV. Conventional free-air thermal current is 63 A at 40 °C; enclosed thermal current is 63 A. Rated conditional short-circuit current is 80 kA at 690 V, and rated short-time withstand current is 2.5 kA rms for 1 s. It accepts British Standard A2-A3 fuses and complies with IEC 60947-3. Screw terminals accept stranded or flexible cable from 2.5 to 25 mm², with 12 mm stripping length and 3 to 4 N·m tightening torque. Dimensions are 112 mm wide, 112 mm high, and 109 mm deep; net weight is 1.14 kg.
- OS63GB04F
ABB OS63GB04F fuse switch disconnector, 4-pole, front-operated, base mounting. Rated current 63 A; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV; rated operational voltage 690 V AC. Conventional free-air thermal current 63 A at 40 °C; enclosed thermal current 63 A. Rated conditional short-circuit current 80 kA at 690 V; short-time withstand current 2.5 kA rms for 1 s. Power loss 4 W per pole at rated operating conditions. Fuse size A2-A3, British Standard fuse system; fourth pole switched and fusible. Screw terminals accept 2.5 to 25 mm² stranded or flexible cable; tightening torque 3 to 4 N·m; stripping length 12 mm. Pollution degree 3. Dimensions 109 x 136 x 112 mm; weight 1.2 kg. Conforms to IEC 60947-3. Handle and shaft not included.
- OS63GB04FP
ABB OS63GB04FP fuse switch disconnector, 4-pole, front-operated, base mounting. Rated current 63 A in the main circuit; conventional free-air thermal current 63 A at 40 °C and conventional thermal current 63 A fully enclosed. Rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 2.5 kA rms for 1 s. Fuse system British Standard, fuse size A2-A3; fourth pole switched-fusible. Screw terminals accept stranded or flexible cable 2.5 to 25 mm²; tightening torque 3 to 4 N·m; wire stripping length 12 mm. Power loss 4 W per pole at rated operating conditions. Pollution degree 3. Handle and shaft included. Standards: IEC 60947-3. Net dimensions 190 x 170 x 145 mm; net weight 1.4 kg.
- OS63GB04N1
The ABB OS63GB04N1 is a four-pole fuse switch disconnector for base mounting, front operated, with the fourth pole on the left side as a switched pole with solid link. It uses British Standard fuses in sizes A2-A3 and accepts stranded or flexible cable from 2.5 to 25 mm² in screw terminals, tightened to 3 N·m or 4 N·m with a 12 mm stripping length. Ratings are 63 A at 40 °C free air and 63 A fully enclosed, 690 V AC, 1000 V insulation voltage, and 12 kV impulse withstand. Rated conditional short-circuit current is 80 kA at 690 V, and short-time withstand current is 2.5 kA rms for 1 s. It conforms to IEC 60947-3. Handle and shaft are not included.