- NX40E-81
The ABB NX40E-81 is an intermediate relay with four normally open auxiliary contacts and no normally closed contacts. It measures 44 mm wide, 74 mm deep, and 74 mm high, and weighs 0.315 kg. Rated operational voltage is 690 V for both auxiliary and main circuits, at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated control circuit voltage is 24 V at 50 Hz and 24 V at 60 Hz. Screw terminals are used. Maximum mechanical switching frequency is 6000 cycles per hour; maximum electrical switching frequency is 1200 cycles per hour at AC-15 and 900 cycles per hour at DC-13. Coil terminals have IP20 protection according to IEC 60529, IEC 60947-1, and EN 60529.
- NX40E-83
The ABB NX40E-83 is an intermediate relay with four normally open auxiliary contacts and no normally closed contacts. It uses screw terminals and measures 44 mm wide, 74 mm deep, and 74 mm high, with a net weight of 0.315 kg. The rated operational voltage is 690 V for both auxiliary and main circuits at 50 or 60 Hz, and the rated control circuit voltage is 48 V at 50 Hz and 60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V according to IEC 60947-5-1 and VDE 0110 (Gr. C), with a rated impulse withstand voltage of 6 kV for the auxiliary circuit. Coil terminals are IP20 according to IEC 60529, IEC 60947-1, and EN 60529.
- NX40E-84
ABB NX40E-84 intermediate relay, manufacturer ID 1SBH901074R8440. It has 4 NO auxiliary contacts and no NC contacts, with screw terminals. Rated operational voltage is 690 V for both auxiliary and main circuits at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V according to IEC 60947-5-1 and VDE 0110 (Gr. C); rated impulse withstand voltage for the auxiliary circuit is 6 kV. Dimensions are 44 mm width, 74 mm depth, and 74 mm height, weighing 0.315 kg. Coil control voltage is 110 V at 50 Hz and 110 to 120 V at 60 Hz. Coil terminals are IP20 according to IEC 60529, IEC 60947-1, and EN 60529.
- NX40E-85
The ABB NX40E-85 is a 4-pole contactor relay with four normally open auxiliary contacts and no normally closed contacts. It measures 44 mm wide, 74 mm deep, and 74 mm high, and weighs 0.315 kg. Rated operational voltage is 690 V for both auxiliary and main circuits at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V per IEC 60947-5-1 and VDE 0110 (Gr. C); rated impulse withstand voltage for the auxiliary circuit is 6 kV. Control circuit voltage is 380 to 400 V at 50 Hz and 400 to 415 V at 60 Hz. Screw terminals are used. Coil terminals are IP20 per IEC 60529, IEC 60947-1, and EN 60529.
- NX40E-86
The ABB NX40E-86 is a 4-pole contactor relay with four normally open auxiliary contacts and no normally closed contacts. It is identified by manufacturer ID 1SBH901074R8640. The rated control circuit voltage is 400 to 415 V at 50 Hz and 415 to 440 V at 60 Hz. Rated operational voltage is 690 V for both auxiliary and main circuits, with a rated insulation voltage of 690 V according to IEC 60947-5-1 and VDE 0110 (Gr. C). Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 degrees C. Maximum mechanical switching frequency is 6000 cycles per hour. Dimensions are 44 mm width, 74 mm depth, and 74 mm height; net weight is 0.315 kg. Coil terminals have IP20 protection according to IEC 60529, IEC 60947-1, and EN 60529.
- NX40E-88
ABB NX40E-88 intermediate relay (contactor relay) with four normally open auxiliary contacts and no normally closed auxiliary contacts. Rated control circuit voltage is 230 to 240 V at 50 Hz and 240 to 260 V at 60 Hz. Rated operational voltage is 690 V for both auxiliary and main circuits, at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V according to IEC 60947-5-1 and VDE 0110 (Gr. C); rated impulse withstand voltage for the auxiliary circuit is 6 kV. Screw terminals. Dimensions are 44 mm wide, 74 mm deep, and 74 mm high; net weight 0.315 kg.
- NX40E-75
ABB NX40E-75 intermediate relay, manufacturer ID 1SBH901074R7540. It has four normally open auxiliary contacts and no normally closed contacts, with screw terminals. Dimensions are 44 mm wide, 74 mm deep, and 74 mm high; net weight 0.315 kg. Rated operational voltage is 690 V for both auxiliary and main circuits, at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V according to IEC 60947-5-1 and VDE 0110 (Gr. C); rated impulse withstand voltage for the auxiliary circuit is 6 kV. Coil terminals are IP20 according to IEC 60529, IEC 60947-1, and EN 60529.
- NX40E-36
The ABB NX40E-36 is a 4-pole contactor relay for auxiliary circuits, identified by manufacturer ID 1SBH901074R3640. It has four normally open auxiliary contacts and no normally closed contacts. The rated control circuit voltage is 190 V at 50 Hz and 220 V at 60 Hz. Rated operational voltage is 690 V for both auxiliary and main circuits, with rated frequency 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Maximum electrical switching frequency is 1200 cycles per hour for AC-15 and 900 cycles per hour for DC-13. Dimensions are 44 mm wide, 74 mm deep, and 74 mm high; net weight is 0.315 kg. Terminals are screw type.