- AX09-30-01-86
ABB AX09-30-01-86 AC contactor, manufacturer ID 1SBL901074R8601. Three main contacts NO and one auxiliary contact NC. Rated operational voltage 690 V for main and auxiliary circuits; rated frequency 50/60 Hz for both. Rated control circuit voltage 400 to 415 V at 50 Hz and 415 to 440 V at 60 Hz. Rated operational current AC-3 is 9 A at 380/400 V, 415 V, 440 V, 500 V, and 220/230/240 V at 55 °C, and 7 A at 690 V at 55 °C. Rated operational power AC-3 is 4 kW at 380/400 V, 415 V, and 440 V, and 5.5 kW at 500 V and 690 V. Dimensions 44 mm width, 74 mm depth, 74 mm height; net weight 0.326 kg. Screw terminals, IP20. Ambient air temperature -40 to 70 °C near contactor in free air.
- AX09-30-01-88
The ABB AX09-30-01-88 is an AC contactor with three normally open main contacts and one normally closed auxiliary contact. It has screw terminals and measures 44 mm wide, 74 mm deep, and 74 mm high, weighing 0.326 kg. Rated operational voltage is 690 V for both main and auxiliary circuits at 50/60 Hz. Rated operational current AC-3 is 9 A at 415 V, 440 V, 500 V, and 380/400 V, and 7 A at 690 V, all at 55 °C. Rated operational power AC-3 is 4 kW at 415 V, 440 V, and 380/400 V, 5.5 kW at 500 V and 690 V, and 2.2 kW at 220/230/240 V. Coil voltage is 230 to 240 V at 50 Hz and 240 to 260 V at 60 Hz.
- AX09-30-10-26
The ABB AX09-30-10-26 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 24 A according to IEC 60947-4-1 for open contactors at 40 °C, and 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 9 A at 415 V and 55 °C, and 7 A at 690 V and 55 °C. Rated operational power AC-3 is 4 kW at 415 V and 5.5 kW at 690 V. Dimensions are 44 mm wide, 74 mm deep, and 74 mm high, with a net weight of 0.326 kg. Rated insulation voltage is 690 V according to IEC 60947-4-1 and VDE 0110 (Gr. C).
- AX09-30-10-36
The ABB AX09-30-10-36 is an AC-operated block contactor with three normally open main contacts and one normally open auxiliary contact. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 9 A at 415 V, 440 V, 500 V, 380/400 V, and 220/230/240 V (55 °C), and 7 A at 690 V (55 °C). Rated operational power AC-3 is 4 kW at 415 V, 440 V, and 380/400 V, 5.5 kW at 500 V and 690 V, and 2.2 kW at 220/230/240 V. Coil voltage is 190 V at 50 Hz and 220 V at 60 Hz. Dimensions are 44 mm wide, 74 mm deep, and 74 mm high; net weight 0.326 kg. Terminals are screw type, IP20.
- AX09-30-10-75
The ABB AX09-30-10-75 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 24 A according to IEC 60947-4-1 at 40 °C, and 16 A according to IEC 60947-5-1 at 40 °C. AC-3 rated operational current is 9 A at 415 V and 7 A at 690 V, both at 55 °C. AC-3 rated operational power is 4 kW at 415 V and 5.5 kW at 690 V. Maximum breaking capacity is 250 A at 440 V and 90 A at 690 V. Dimensions are 44 mm wide, 74 mm deep, and 74 mm high; net weight is 0.326 kg.
- AX09-30-10-80
The ABB AX09-30-10-80 is an AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 44 mm wide, 74 mm deep, and 74 mm high, and weighs 0.326 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated control circuit voltage is 220 to 230 V at 50 Hz and 230 to 240 V at 60 Hz. Rated operational current AC-3 is 9 A at 415 V and 7 A at 690 V, both at 55 °C. Rated operational power AC-3 is 4 kW at 415 V and 5.5 kW at 690 V. Terminals are screw type, with IP20 protection on main, auxiliary, and coil terminals.
- AX09-30-10-81
The ABB AX09-30-10-81 is an AC contactor with three main poles (3 NO, 0 NC) and one built-in auxiliary contact (1 NO, 0 NC). The coil is rated 24 V at both 50 Hz and 60 Hz. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Conventional free-air thermal current is 24 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. AC-3 rated operational current is 9 A at 380/400 V, 415 V, 440 V, 500 V, and 220/230/240 V, all at 55 °C, and 7 A at 690 V at 55 °C. AC-3 rated power is 4 kW at 380/400 V and 415 V, 5.5 kW at 500 V and 690 V, and 2.2 kW at 220/230/240 V. Dimensions are 44 mm wide, 74 mm deep, 74 mm high; weight 0.326 kg. Terminals are screw type, IP20.
- AX09-30-10-83
The ABB AX09-30-10-83 is an AC contactor with three normally open main contacts and one normally open auxiliary contact. Its coil is rated 48 V at 50 Hz and 60 Hz. Rated operational voltage is 690 V for both main and auxiliary circuits, with rated frequency 50/60 Hz. Rated operational current AC-3 is 9 A at 380/400 V, 415 V, 440 V, 500 V, and 220/230/240 V at 55 °C, and 7 A at 690 V at 55 °C. Rated operational power AC-3 is 4 kW at 380/400 V, 415 V, and 440 V, 5.5 kW at 500 V and 690 V, and 2.2 kW at 220/230/240 V. Dimensions are 44 mm width, 74 mm depth, 74 mm height; net weight 0.326 kg. Terminals are screw type, IP20.