- AX06-30-10-88
ABB AC contactor AX06-30-10-88, manufacturer ID 1SBL891074R8810. Three main contacts NO, no main contacts NC, and one auxiliary contact NO. Rated operational voltage is 690 V for both main and auxiliary circuits at 50/60 Hz. Rated operational current AC-1 is 20 A at 220/240 V and 55 °C, and 20 A at 690 V and 40 °C. Rated operational current AC-3 is 7 A at 380/400 V and 55 °C. Rated control circuit voltage is 230 to 240 V at 50 Hz and 240 to 260 V at 60 Hz. Screw terminals, coil terminals IP20 per IEC 60529. Dimensions are 44 mm width, 74 mm depth, and 74 mm height; net weight 0.326 kg.
- AX09-30-01-26
ABB AC contactor, display model AX09-30-01-26, manufacturer ID 1SBL901074R2601. Three main contacts NO, zero main contacts NC, and one auxiliary contact NC. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50 / 60 Hz. Conventional free-air thermal current is 24 A according to IEC 60947-4-1 at 40 °C, and 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 9 A at 415 V, 440 V, 500 V, 380 / 400 V, and 220 / 230 / 240 V, and 7 A at 690 V, all at 55 °C. Rated operational power AC-3 is 4 kW at 415 V, 440 V, and 380 / 400 V, 5.5 kW at 500 V and 690 V, and 2.2 kW at 220 / 230 / 240 V. Dimensions are 44 mm width, 74 mm depth, 74 mm height; net weight 0.326 kg.
- AX09-30-01-36
The ABB AX09-30-01-36 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Rated operational current AC-3 is 9 A at 380/400 V, 415 V, 440 V, 500 V, and 220/230/240 V (55 °C), and 7 A at 690 V (55 °C). Rated operational power AC-3 is 4 kW at 380/400 V, 415 V, and 440 V, 5.5 kW at 500 V and 690 V, and 2.2 kW at 220/230/240 V. The coil is rated 190 V at 50 Hz and 220 V at 60 Hz. Dimensions are 44 mm wide, 74 mm deep, and 74 mm high; net weight is 0.326 kg. Terminals are screw type, IP20.
- AX09-30-01-75
ABB AX09-30-01-75 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 44 mm wide, 74 mm deep, and 74 mm high, and weighs 0.326 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 24 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 9 A at 415 V, 440 V, 500 V, and 380/400 V, and 7 A at 690 V, all at 55 °C. Rated insulation voltage is 690 V per IEC 60947-4-1 and VDE 0110 (Gr. C). Manufacturer ID: 1SBL901074R7501.
- AX09-30-01-80
The ABB AX09-30-01-80 is an AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 44 mm wide, 74 mm deep, and 74 mm high, and weighs 0.326 kg. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Rated operational current AC-3 is 9 A at 415 V, 440 V, 500 V, and 380/400 V, and 7 A at 690 V, all at 55 °C. Rated operational power AC-3 is 4 kW at 415 V and 380/400 V, 5.5 kW at 500 V and 690 V, and 2.2 kW at 220/230/240 V. The coil is rated 220 to 230 V at 50 Hz and 230 to 240 V at 60 Hz. Terminals are screw type, IP20. Maximum operating altitude without derating is 3000 m.
- AX09-30-01-81
The ABB AX09-30-01-81 is an AC contactor with three normally open main contacts and one normally closed auxiliary contact. It has a rated operational voltage of 690 V for both main and auxiliary circuits, and a rated frequency of 50/60 Hz. The rated control circuit voltage is 24 V at 50 Hz and 24 V at 60 Hz. Rated operational current AC-3 is 9 A at 415 V, 440 V, 500 V, 380/400 V, and 220/230/240 V, and 7 A at 690 V, all at 55 °C. Rated operational power AC-3 is 4 kW at 415 V, 440 V, and 380/400 V, 5.5 kW at 500 V and 690 V, and 2.2 kW at 220/230/240 V. Dimensions are 44 mm width, 74 mm depth, 74 mm height, and 0.326 kg net weight. Terminals are screw type with IP20 protection.
- AX09-30-01-83
The ABB AX09-30-01-83 is a block-type AC contactor with three normally open main contacts and one normally closed auxiliary contact. It is rated 690 V for both main and auxiliary circuits at 50/60 Hz, with a rated control circuit voltage of 48 V at 50 Hz and 60 Hz. Rated operational current is 9 A at AC-3, 380/400 V and 55 °C, corresponding to 4 kW; AC-1 ratings include 22 A at 690 V and 40 °C. Dimensions are 44 mm wide, 74 mm deep, and 74 mm high, weighing 0.326 kg. Terminals are screw type with IP20 protection. Maximum mechanical switching frequency is 3600 cycles per hour, and maximum operating altitude without derating is 3000 m.
- AX09-30-01-84
ABB AX09-30-01-84 is a block-type AC contactor with 3 main poles (NO) and 1 built-in auxiliary contact (NC). Rated operational voltage is 690 V for both main and auxiliary circuits; rated frequency is 50/60 Hz. Coil control voltage is 110 V at 50 Hz and 110 to 120 V at 60 Hz. Rated operational current AC-3 is 9 A at 415 V, 440 V, 500 V, 380/400 V and 220/230/240 V, and 7 A at 690 V, all at 55 °C. Rated operational power AC-3 is 4 kW at 415 V, 440 V and 380/400 V, 5.5 kW at 500 V and 690 V, and 2.2 kW at 220/230/240 V. Dimensions are 44 mm wide, 74 mm deep and 74 mm high; net weight 0.326 kg. Terminals are screw type, IP20.