Image for reference. Confirm the exact model and condition with your quote.
SIEMENS 7ML5050-0BA22-1DA0
- Warehouse stock, ready to ship
- Fully genuine original parts
- Free quotes within 24 hours
Q1Can you supply the SIEMENS 7ML5050-0BA22-1DA0?Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.
Q2What will the SIEMENS 7ML5050-0BA22-1DA0 cost me?Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.
Q3Are your products genuine?Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.
- Product Model
- 7ML5050-0BA22-1DA0
- Material Number
- 7ml50500ba221da0
- Manufacturer
- SIEMENS
- Product ID
- 734473
Key specifications
- Transducer frequency
- 10 ... 52 kHz
- Ambient temperature (enclosure)
- -20 ... +50 °C (-4 ... +122 °F)
- Weight (enclosure with display lid)
- 1.3 kg (2.87 lb)
- Degree of protection (enclosure with display or blank lid)
- IP65/Type 4X/NEMA 4X
- Communication
- HART 7.0, USB
- Input voltage
- 10 ... 32 V DC, 10 W
See all specifications7ML5050-0BA22-1DA0
Product Information
Technical Specifications
Specifications for 7ML5050-0BA22-1DA0
| Parameter | Value |
|---|
| Mode of operation | Ultrasonic level, volume, pump, and open channel flow |
|---|
| Measuring range | 0.3 ... 60 m (1 ... 196 ft), transducer dependent |
|---|
| Discrete input | 0 ... 50 V DC switching level (logical 0 ≤ 10 V DC; logical 1 = 10 ... 50 V DC), max. 3 mA |
|---|
| Transducer frequency | 10 ... 52 kHz |
|---|
| Compatible transducers | All EchoMax and ST-H series transducers |
|---|
| Relays | 1 SPDT Form C, NO or NC (1 A at 250 V AC, 3 A at 30 V DC); 2 SPST Form A, NO (5 A at 250 V AC, 3 A at 30 V DC) |
|---|
| mA output | 4 ... 20 mA, isolated |
|---|
| Max. load | 600 Ω max. in ACTIVE mode, 750 Ω max. in PASSIVE mode |
|---|
| Error in measurement (standard operation) | ±1 mm (0.04 inch) plus 0.17 % of measured distance |
|---|
| Resolution (standard operation) | 0.1 % of range or 2 mm (0.08 inch), whichever is greater |
|---|
| Temperature compensation | -40 ... +150 °C (-40 ... +300 °F), integral temperature sensor in transducer |
|---|
| Location | Indoor/outdoor |
|---|
| Installation category | II |
|---|
| Pollution degree | 4 |
|---|
| Ambient temperature (enclosure) | -20 ... +50 °C (-4 ... +122 °F) |
|---|
| Storage temperature | -20 ... +50 °C (-4 ... +122 °F) |
|---|
| Weight (enclosure with display lid) | 1.3 kg (2.87 lb) |
|---|
| Material (enclosure) | Polycarbonate |
|---|
| Degree of protection (enclosure with display or blank lid) | IP65/Type 4X/NEMA 4X |
|---|
| Max. separation between transducer and transceiver | 365 m (1,200 ft) |
|---|
| Communication | HART 7.0, USB |
|---|
| Memory | 512 kB flash EPROM; 1.5 MB flash for data logging |
|---|
| Model | SITRANS LUT430 - Level, Pump & Flow controller |
|---|
| Enclosure display options | With display |
|---|
| Parameter | Value |
|---|
| Input voltage | 10 ... 32 V DC, 10 W |
|---|
| Cable inlet | 3 cable inlets, 3 M20 plastic cable glands supplied |
|---|
| Number of measurement points | Single point system (one transducer input, one mA output, one external temperature sensor input) |
|---|
| Communications and I/O | HART, 2 discrete inputs, 3 relays |
|---|
| Approvals | Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL, RCM, EAC, KC |
|---|
| Open channel flow measurement | Yes |
|---|
| Integrated datalogger for fixed rate flow logging | Yes |
|---|
| Daily data logging | Yes (maximum, minimum and average flow, daily totalized volume, minimum and maximum temperature) |
|---|
| 9-digit daily and running flow totalizers | Yes |
|---|
| High and low flowrate alarms | Yes |
|---|
| External totalizer and sampler control | Yes |
|---|
| MCERTS Class 2 Certification | Yes |
|---|
| Energy saving algorithms for pump control | Yes |
|---|
| Pump run-on functionality | Yes |
|---|
| Pump start and power resumption delays | Yes |
|---|
| Fixed duty and service ratio pump routines | Yes |
|---|
| Pumped volume totalizer | Yes |
|---|
| Discrete input pump interlocks | Yes |
|---|
| Time to spill calculation | Yes |
|---|
Specifications may change. Confirm the exact model, revision and offered condition with your quotation.
Need Help Checking This Part?
Ask about specifications, condition or a suitable alternative.
Contact Us on WhatsApp WhatsApp