- AS040C
ABB AS040C O-ring set, supplied as 10 pieces per bag. Each set has a net weight of 0.013 kg. Individual O-ring dimensions are 72.75 mm length, 72.75 mm width, and 1.78 mm height. The part is classified as a spare part.
- AS09-30-01-20
The ABB AS09-30-01-20 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. Its coil is rated 24 V at 50 Hz and 60 Hz. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Rated operational current AC-3 is 9 A at 380/400 V, 415 V, 220/230/240 V, and 8 A at 440 V and 500 V, 5 A at 690 V, at 60 °C. Rated operational power AC-3 is 4 kW at 400 V through 690 V and 2.2 kW at 220/230/240 V. It uses screw terminals, measures 45 mm wide, 72.5 mm deep, and 68 mm high, and weighs 0.22 kg. Standards: IEC 60947-1 / 60947-4-1, EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 No. 14.
- AS09-30-01-25
The ABB AS09-30-01-25 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 72.5 mm deep, and 68 mm high, and weighs 0.22 kg. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Rated operational current AC-3 is 9 A at 415 V and 380/400 V, 8 A at 440 V and 500 V, and 5 A at 690 V, at 60 °C. Rated operational power AC-3 is 4 kW at 400 V, 415 V, 440 V, 500 V, and 690 V, and 2.2 kW at 220/230/240 V. The coil is rated 220 V at 50 Hz and 60 Hz. Terminals are screw type, IP20, with 9 mm stripping length. Standards: IEC 60947-1/60947-4-1, EN 60947-1/60947-4-1, UL 508, CSA C22.2 N°14.
- AS09-30-01-26
ABB AS09-30-01-26 AC contactor with manufacturer ID 1SBL101001R2601. It has three normally open main contacts and one normally closed auxiliary contact, rated operational voltage 690 V for both main and auxiliary circuits at 50/60 Hz. Rated operational current AC-3 is 9 A at 380/400 V and 415 V, 8 A at 440 V and 500 V, and 5 A at 690 V, all at 60 °C. Rated operational power AC-3 is 4 kW at 400 V, 415 V, 440 V, 500 V, and 690 V, and 2.2 kW at 220/230/240 V. Coil voltage is 230 V at 50 Hz and 60 Hz. Dimensions are 45 mm width, 72.5 mm depth, and 68 mm height, with 0.22 kg net weight. Screw terminals accept rigid conductors 0.75 to 4 mm² in the main circuit. Standards: IEC 60947-1 / 60947-4-1, EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14.
- AS09-30-01S-20
The ABB AS09-30-01S-20 is an AC contactor with three main contacts NO, no main contacts NC, and one auxiliary contact NC. The control circuit voltage is 24 V at both 50 Hz and 60 Hz. Rated operational power AC-3 is 4 kW at 400 V, 415 V, 440 V, 500 V, and 690 V, and 2.2 kW at 220/230/240 V. Rated operational current AC-3 is 9 A at 415 V, 380/400 V, and 220/230/240 V, 8 A at 440 V and 500 V, and 5 A at 690 V, all at 60 °C. Terminals are spring type, with 10 mm wire stripping length. Dimensions are 45 mm width, 72.5 mm depth, 68 mm height, and 0.22 kg net weight. Standards: IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14.
- AS09-30-01S-26
The ABB AS09-30-01S-26 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It uses spring terminals and measures 45 mm wide, 72.5 mm deep, and 68 mm high, weighing 0.22 kg. The coil is rated 230 V at 50 Hz and 60 Hz. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Rated operational current AC-3 is 9 A at 380/400 V, 415 V, 220/230/240 V, and 8 A at 440 V and 500 V, and 5 A at 690 V, all at 60 degrees C. Rated operational power AC-3 is 4 kW at 400 V, 415 V, 440 V, 500 V, and 690 V, and 2.2 kW at 220/230/240 V. Standards: IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 No.14.
- AS09-30-10-25
The ABB AS09-30-10-25 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It has a rated control circuit voltage of 220 V at 50 Hz and 60 Hz. Rated operational current AC-3 is 9 A at 380/400 V, 415 V, and 220/230/240 V at 60 °C, and rated operational power AC-3 is 4 kW at 400 V, 415 V, 440 V, 500 V, and 690 V. Rated frequency is 50/60 Hz for main and auxiliary circuits. It uses screw terminals with 9 mm stripping length and IP20 protection on main, auxiliary, and coil terminals. Standards: IEC 60947-1 / 60947-4-1, EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14. Dimensions are 45 mm wide, 72.5 mm deep, and 68 mm high; net weight 0.22 kg.
- AS09-30-10-26
ABB AS09-30-10-26 AC contactor, manufacturer ID 1SBL101001R2610. It has three main normally open contacts and one auxiliary normally open contact, with screw terminals. Rated operational voltage is 690 V for both main and auxiliary circuits at 50/60 Hz. Rated operational current AC-3 is 9 A at 380/400 V and 415 V, 8 A at 440 V and 500 V, and 5 A at 690 V, all at 60 °C. Rated operational power AC-3 is 4 kW at 400 V, 415 V, 440 V, 500 V, and 690 V, and 2.2 kW at 220/230/240 V. Coil voltage is 230 V at 50 Hz and 60 Hz. Dimensions are 45 mm width, 72.5 mm depth, 68 mm height; net weight 0.22 kg. Standards: IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14.