Industrial Automation Parts. Prompt replies from real people.

ABB B6-22-00-F-01 AC contactor

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/25/2026

Q1Can you supply the ABB B6-22-00-F-01?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the ABB B6-22-00-F-01 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
B6-22-00-F-01
Material Number
GJL1211503R0001
Manufacturer
ABB
Product ID
71283

Get a Free Quote

Request pricing and availability for B6-22-00-F-01.

More parts to source? Send your whole list in one enquiry

Key specifications

Product Net Weight
0.17 kg
Rated Operational Voltage
Main Circuit 690 V AC Main Circuit 220 V DC
Rated Frequency (f)
Control Circuit 400 Hz Control Circuit 50 Hz Control Circuit 60 Hz Main Circuit 60 Hz Main Circuit 50 Hz Main Circuit DC
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 6 kV
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 40 °C 20 A (220 / 240 V) 55 °C 16 A (380 / 440 V) 40 °C 20 A (380 / 440 V) 55 °C 16 A (690 V) 40 °C 6 A (690 V) 55 °C 6 A
Rated Operational Power AC-3 (Pe)
(230 V) Three Phase 2.2 kW (400 V) Three Phase 4 kW (500 V) Three Phase 4 kW (690 V) Three Phase, NC 3 kW (690 V) Three Phase, NO 3 kW
See all specifications

Product Highlights

  1. Compact Mini Contactor: 4-pole AC contactor with 2 NO and 2 NC main contacts, measuring 52.5 x 57.5 x 46.7 mm and weighing 0.17 kg
  2. Current Ratings: AC-1 rated operational current of 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V
  3. Motor Power Ratings: AC-3 rated operational power of 2.2 kW at 230 V, 4 kW at 400/500 V, and 3 kW at 690 V three-phase
  4. Coil and Control: 24 V AC control circuit voltage with operating limits of 0.85 to 1.1 x Uc at up to 55 °C, and control circuit frequency of 50/60/400 Hz
  5. Durability and Mounting: Mechanical durability of 10 million cycles, maximum switching frequency up to 600 cycles per hour, and DIN rail mounting per IEC 60715
B6-22-00-F-01

Product Information

Technical Specifications

Specifications for B6-22-00-F-01

ParameterValue
Product Net Width52.5 mm
Product Net Height57.5 mm
Product Net Depth / Length46.7 mm
Product Net Weight0.17 kg
Number of Poles4P
Mini Contactor TypeMini Contactor
Rated Operational VoltageMain Circuit 690 V AC Main Circuit 220 V DC
Rated Frequency (f)Control Circuit 400 Hz Control Circuit 50 Hz Control Circuit 60 Hz Main Circuit 60 Hz Main Circuit 50 Hz Main Circuit DC
Rated Impulse Withstand Voltage (Uimp)Main Circuit 6 kV
Rated Insulation Voltage (Ui)690 V acc. to UL/CSA 600 V
Number of Main Contacts NC2
Number of Main Contacts NO2
Rated Operational Current AC-1 (Ie)(220240 V) 40 °C 20 A (220240 V) 55 °C 16 A (380440 V) 40 °C 20 A (380440 V) 55 °C 16 A (690 V) 40 °C 6 A (690 V) 55 °C 6 A
Rated Operational Power AC-3 (Pe)(230 V) Three Phase 2.2 kW (400 V) Three Phase 4 kW (500 V) Three Phase 4 kW (690 V) Three Phase, NC 3 kW (690 V) Three Phase, NO 3 kW
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 64 A
Number of Auxiliary Contacts NC0
Number of Auxiliary Contacts NO0
Conventional Free-air Thermal Current (Ith)Main Circuit 20 A
Rated Control Circuit Voltage (Uc)24 V AC
ParameterValue
Coil Operating Limits(acc. to IEC 60947-4-1) for AC supply 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
Degree of ProtectionControl Circuit Terminals IP20 Main Circuit Terminals IP20
Mechanical Durability10000000 cycle
Maximum Electrical Switching Frequency(AC-1) 300 cycles per hour (AC-3) 600 cycles per hour (DC-1) 600 cycles per hour (DC-3) 600 cycles per hour
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Power Lossat Rated Operating Conditions AC-1 per Pole 1 W
StandardsIEC/EN 60947-1 IEC/EN 60947-4-1 IEC/EN 60947-5-1 UL 60947-1 UL 60947-4-1
Maximum Operating Voltage UL/CSAMain Circuit 600 V AC
Full Load Amps Motor Use(115 V AC) Single Phase 5.8 A (200 V AC) Three Phase 4.8 A (220 ... 240 V AC) Three Phase 6.8 A (230 V AC) Single Phase 4.9 A (440 ... 480 V AC) Three Phase 4.8 A (550 ... 600 V AC) Three Phase 1.7 A
Horsepower Rating UL/CSA(115 V AC) Single Phase 0.25 Hp (200 V AC) Three Phase 1 Hp (220 ... 240 V AC) Three Phase 2 Hp (230 V AC) Single Phase 0.5 Hp (440 ... 480 V AC) Three Phase 3 Hp (550 ... 600 V AC) Three Phase 1 Hp
General Use Rating UL/CSA(300 V AC) 12 A
Ambient Air TemperatureOperation -20 ... +55 °C Storage -40 ... +80 °C
Maximum Operating Altitude Permissible2000 m
Resistance to Shock acc. to IEC 60068-2-2711 ms Pulse 15g
Resistance to Vibrations5g 5 ... 150 Hz
Object Classification CodeQ
ETIM 4EC000066 - Magnet contactor, AC-switching
ETIM 5EC000066 - Magnet contactor, AC-switching
ETIM 6EC000066 - Power contactor, AC switching
ETIM 7EC000066 - Power contactor, AC switching
ETIM 8EC000066 - Power contactor, AC switching
eClassV11.0 : 27371003
UNSPSC39121529
Manufacturer IDGJL1211503R0001

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp