- OT1000BBAA3AZ
ABB isolating switch OT1000BBAA3AZ, 3-pole, surface-mount, in a steel sheet enclosure. Conventional thermal current (Ithe) is 1000 A fully enclosed. Rated operational current is 1000 A at 380–415 V, 500 V, and 690 V for AC-22A and AC-23A; rated operational power AC-23A is 560 kW at 380–415 V, 710 kW at 500 V, and 1000 kW at 690 V. Rated insulation voltage is 1000 V per IEC/EN 60664-1; main circuit rated operational voltage is 1000 V. Rated short-circuit making capacity is 110 kA at 690 V AC, and rated short-time withstand current is 50 kA for 1 s. Degree of protection is IP65 per IEC 60529. Standards: IEC 60947-1, -3. Pistol handle, red/yellow. Mounted auxiliary contacts 2 NO, 1 NC; maximum 2 NO, 2 NC. Dimensions 400 x 1200 x 330 mm; net weight 53 kg.
- OT1000BBAA3T
ABB isolating switch OT1000BBAA3T, manufacturer ID 1SCA022320R9550. Three-pole (3P) enclosed switch with steel sheet enclosure, IP65 acc. to IEC 60529. Conventional thermal current (Ithe) 1000 A fully enclosed. Rated insulation voltage (Ui) 1000 V acc. to IEC/EN 60664-1. Power loss 19 W per pole at rated operating conditions. Line and PE terminals top in, bottom out. Cable entry up/down, open outlets per side. Connecting capacity: 12 mm hole diameter screw clamp, PE terminal 8 pcs, 25 to 120 mm². Black pistol handle. Mounted auxiliary contacts 2 NO, 1 NC; maximum 2 NO, 2 NC. Dimensions 400 mm wide, 1200 mm high, 330 mm deep; net weight 55.09 kg.
- OT1000BBAA3TZ
ABB OT1000BBAA3TZ isolating switch, manufacturer ID 1SCA102814R1001, is a 3-pole enclosed switch disconnector in a steel sheet enclosure. Rated insulation voltage is 1000 V acc. to IEC/EN 60664-1; rated operational voltage of the main circuit is 1000 V. Conventional thermal current (Ithe) is 1000 A fully enclosed. Rated operational current AC-23A is 1000 A at 380 to 415 V, 500 V, and 690 V. Rated operational power AC-23A is 560 kW at 380 to 415 V, 710 kW at 500 V, and 1000 kW at 690 V. Rated short-time withstand current Icw is 50 kA for 1 s; rated short-circuit making capacity Icm is 110 kA at 690 V AC. Degree of protection is IP65 acc. to IEC 60529; pollution degree 3. Standards: IEC 60947-1, -3.
- OT1000BBCC3A
The ABB OT1000BBCC3A is a three-pole isolating switch in a steel sheet enclosure, with dimensions of 400 mm wide, 1200 mm high, and 330 mm deep, and a net weight of 60.8 kg. It provides IP65 protection according to IEC 60529. The conventional thermal current is 1000 A fully enclosed. Rated insulation voltage is 1000 V according to IEC/EN 60664-1, and the main circuit rated operational voltage is 1000 V. Rated operational current is 1000 A at 380 to 415 V, 500 V, and 690 V for AC-22A and AC-23A. Rated operational power for AC-23A is 560 kW at 380 to 415 V, 710 kW at 500 V, and 1000 kW at 690 V. Rated short-circuit making capacity is 110 kA at 690 V AC, and rated short-time withstand current is 50 kA for 1 s. Standards: IEC 60947-1 and IEC 60947-3.
- OT1000BBCC3AZ
The ABB OT1000BBCC3AZ is an isolating switch with manufacturer ID 1SCA022512R6920. Its enclosure is steel sheet, rated IP65 according to IEC 60529 and IK09 for impact resistance, with pollution degree 3. Conventional thermal current (Ithe) is 1000 A fully enclosed. Dimensions are 400 mm wide, 1200 mm high, and 330 mm deep; net weight is 57.8 kg. Cable entry is top or bottom, with 3xC-flange per side and knock-outs of 10 mm, 12.5 mm, 20.5 mm, 25.5 mm, and 32.5 mm. Main-circuit connection uses a 12 mm hole diameter screw clamp; PE terminal accommodates 8 pieces, 25 to 120 mm². The pistol handle is red/yellow. Mounted auxiliary contacts are 2 NO and 1 NC, with a maximum of 2 NO and 2 NC. No neutral terminal is provided.
- OT1000BBCC3TZ
The ABB OT1000BBCC3TZ is an enclosed switch-disconnector supplied under manufacturer ID 1SCA022340R3360. Its steel sheet enclosure provides protection to IEC 60529 IP65 and impact resistance to IK09, with pollution degree 3. Conventional thermal current (Ithe) is 1000 A fully enclosed. Dimensions are 400 mm wide, 1200 mm high, and 330 mm deep; net weight is 61.73 kg. Cable entry is top or bottom, with three C-flange outlets per side and knock-outs of 10 mm, 12.5 mm, 20.5 mm, 25.5 mm, and 32.5 mm. Main circuit connection uses a 12 mm hole diameter screw clamp, with PE terminals for 25 to 120 mm². Mounted auxiliary contacts are 2 NO and 1 NC, with a maximum of 2 NO and 2 NC. The pistol handle is black. No neutral terminal is fitted.
- OT1000BBRR3AZ
ABB isolating switch OT1000BBRR3AZ, manufacturer ID 1SCA102815R1001, is a three-pole switch disconnector with a rated insulation voltage of 1000 V according to IEC/EN 60664-1 and a rated operational voltage of 1000 V for the main circuit. Conventional thermal current Ithe is 1000 A fully enclosed. Rated operational current is 1000 A at 380 to 415 V, 500 V, and 690 V for AC-22A and AC-23A; rated operational power AC-23A is 560 kW at 380 to 415 V, 710 kW at 500 V, and 1000 kW at 690 V. The steel sheet enclosure provides IP65 protection according to IEC 60529 and IK09 impact resistance. It measures 400 mm wide, 1200 mm high, and 330 mm deep, weighs 62 kg, and has a red/yellow pistol handle. Standards: IEC 60947-1, -3.
- OT1000BBRR3TZ
ABB OT1000BBRR3TZ isolating switch, manufacturer ID 1SCA022340R3100. Steel sheet enclosure, 400 mm wide, 1200 mm high, 330 mm deep, 62 kg. Degree of protection acc. to IEC 60529 IP65; pollution degree 3; housing impact resistance IK09. Conventional thermal current (Ithe) 1000 A fully enclosed. Cable entry top or bottom, with 4x ring-flange per side and knock-outs of 3x10 mm, 12.5 mm, 20.5 mm, 25.5 mm, and 32.5 mm. Main circuit connection: 12 mm hole diameter screw clamp; PE terminal 8 pc, 25 to 120 mm². Black pistol handle. Mounted auxiliary contacts 2 NO, 1 NC; maximum mounted auxiliary contacts 2 NO, 2 NC. No neutral terminal.