- AF185-30-22-70
The ABB AF185-30-22-70 is a three-phase AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 275 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 185 A at 415 V and 55 °C, and rated operational power AC-3 is 90 kW at 415 V. Short-circuit protection uses gG type fuses rated 355 A. Dimensions are 123.5 mm wide, 160 mm deep, and 196 mm high; net weight is 2.9 kg. Maximum electrical switching frequency is 300 cycles per hour in AC-1 and AC-3.
- AF185-30-22-72
The ABB AF185-30-22-72 is a 3-pole non-reversing AC contactor with three normally open main contacts and no normally closed main contacts. It provides two normally open and two normally closed auxiliary contacts. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 275 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 185 A at 415 V and 55 °C, and rated operational power AC-3 is 90 kW at 415 V. Dimensions are 123.5 mm wide, 160 mm deep, and 196 mm high, with a net weight of 2.9 kg. Manufacturer ID: 1SFL497001R7222.
- AF185B-30-11-69
ABB AF185B-30-11-69 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 275 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 185 A at 415 V and 440 V, 170 A at 500 V and 690 V, and 95 A at 1000 V, all at 55 °C. Rated operational power AC-3 is 90 kW at 415 V and 440 V, 110 kW at 500 V, and 132 kW at 690 V and 1000 V. Dimensions are 111.5 mm wide, 160 mm deep, and 196 mm high; net weight is 3 kg. Standards include IEC/EN 60947-1 and IEC/EN 60947-4-1.
- AF185B-30-11-72
The ABB AF185B-30-11-72 is a non-reversing 3-pole AC contactor with three normally open main contacts and one NO plus one NC auxiliary contact. It measures 111.5 mm wide, 160 mm deep, and 196 mm high, and weighs 3 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 275 A per IEC 60947-4-1 for open contactors at 40 °C. AC-3 rated operational current is 185 A at 415 V and 55 °C, and AC-3 rated operational power is 90 kW at 415 V. Short-circuit protection is provided by gG type fuses rated 160 A. Standards cited include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF185B-30-11RT-69
The ABB AF185B-30-11RT-69 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 111.5 mm wide, 160 mm deep, and 196 mm high, and weighs 2.9 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 275 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 185 A at 415 V and 55 °C, and rated operational power AC-3 is 90 kW at 415 V. Short-circuit protection uses gG type fuses rated 160 A. Applicable standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF185B-30-11RT-70
The ABB AF185B-30-11RT-70 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It is rated 690 V in the main circuit at 50/60 Hz. Conventional free-air thermal current is 275 A per IEC 60947-4-1 for open contactors at 40 °C. AC-3 ratings include 185 A at 415 V and 55 °C, and 170 A at 690 V and 55 °C, with corresponding rated operational power of 90 kW at 415 V and 132 kW at 690 V. Short-circuit protection is provided by gG type fuses rated 160 A. Dimensions are 111.5 mm wide, 160 mm deep, and 196 mm high; net weight is 2.9 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, and EN 50155.
- AF185B-30-11RT-72
The ABB AF185B-30-11RT-72 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 111.5 mm wide, 160 mm deep, and 196 mm high, and weighs 2.9 kg. The main circuit is rated 690 V at 50/60 Hz. Rated operational current AC-3 is 185 A at 415 V and 55 °C, 170 A at 500 V and 55 °C, and 95 A at 1000 V and 55 °C. Rated operational power AC-3 is 90 kW at 415 V and 132 kW at 690 V. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF186
ABB AF186 is an industrial catalog item. Key specifications include Number of Batteries: 0, Product Net Width: 86 mm, Product Net Height: 38 mm, and Product Net Depth / Length: 86 mm. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.