- AF38Z-40-00-21
The ABB AF38Z-40-00-21 is an IEC AC contactor with four normally open main contacts and no auxiliary contacts. The main circuit is rated 690 V, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V according to IEC 60947-4-1, or 600 V according to UL/CSA. The control circuit coil operates at 24 to 60 V AC at 50 or 60 Hz, and 20 to 60 V DC. AC-3 rated operational current is 22 A at 380/400 V and 60 °C, and rated operational power is 11 kW at 400 V. Screw terminals accept main circuit conductors from 1.5 to 16 mm². Dimensions are 45 mm wide, 101 mm deep, and 86 mm high, with a net weight of 0.4 kg.
- AF38Z-40-00-22
ABB AF38Z-40-00-22 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It is rated for a main circuit operational voltage of 690 V and a rated insulation voltage of 690 V according to IEC 60947-4-1 (600 V according to UL/CSA). Rated operational current AC-3 is 22 A at 380/400 V and 60 °C, 20 A at 440 V and 60 °C, and 10.5 A at 690 V and 60 °C. Rated operational power AC-3 is 11 kW at 400 V and 9 kW at 690 V. The control circuit accepts 48 to 130 V at 50 Hz, 60 Hz, or DC. Dimensions are 45 mm wide, 101 mm deep, and 86 mm high, with a net weight of 0.4 kg. Screw terminals accept main circuit conductors from 1.5 to 16 mm².
- AF38Z-40-00-23
The ABB AF38Z-40-00-23 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 101 mm deep, and 86 mm high, and weighs 0.4 kg. The main circuit is rated 690 V at 50/60 Hz, with a rated insulation voltage of 690 V according to IEC 60947-4-1 and 600 V according to UL/CSA, and a rated impulse withstand voltage of 6 kV. Conventional free-air thermal current is 55 A according to IEC 60947-4-1 for open contactors at 40 degrees C. AC-3 ratings include 22 A at 380/400 V and 11 kW at 400 V, both at 60 degrees C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.
- AF38ZB-22-00-21
The ABB AF38ZB-22-00-21 is a 4-pole AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It measures 45 mm wide, 101 mm deep, and 86 mm high, and weighs 0.41 kg. The main circuit is rated 690 V, with a rated impulse withstand voltage of 6 kV and an insulation voltage of 690 V according to IEC 60947-4-1 and 600 V according to UL/CSA. Conventional free-air thermal current is 55 A at 40 °C per IEC 60947-4-1. AC-3 rated operational power is 11 kW at 400 V, 415 V, 440 V, and 500 V, and 9 kW at 690 V. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, and CSA C22.2 No. 60947-4-1.
- AF38ZB-22-00-22
The ABB AF38ZB-22-00-22 is a 4-pole AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It measures 45 mm wide, 101 mm deep, and 86 mm high, and weighs 0.41 kg. The main circuit is rated 690 V with a rated impulse withstand voltage of 6 kV and an insulation voltage of 690 V according to IEC 60947-4-1 and 600 V according to UL/CSA. Rated operational current AC-3 is 22 A at 380/400 V and 60 °C, and rated operational power AC-3 is 11 kW at 400 V. Conventional free-air thermal current is 55 A at 40 °C. It is declared to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, and CSA C22.2 No. 60947-4-1.
- AF38ZB-22-00-23
The ABB AF38ZB-22-00-23 is a 4-pole AC contactor with 2 NO and 2 NC main contacts and screw terminals. It has a rated operational voltage of 690 V in the main circuit and operates at 50/60 Hz. Rated operational power in AC-3 is 11 kW at 400 V, 415 V, 440 V, and 500 V, and 9 kW at 690 V. Conventional free-air thermal current is 55 A at 40 °C per IEC 60947-4-1. Dimensions are 45 mm wide, 101 mm deep, and 86 mm high, with a net weight of 0.41 kg. It carries no auxiliary contacts. Standards include IEC/EN 60947-1 and IEC/EN 60947-4-1.
- AF38ZB-22-00RT-21
The ABB AF38ZB-22-00RT-21 is an AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It has ring-tongue terminals and mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715, or on 2 x M4 screws placed diagonally. Main circuit rated operational voltage is 690 V, with rated insulation voltage 690 V per IEC 60947-4-1 and 600 V per UL/CSA, and rated impulse withstand voltage 6 kV. Rated operational power AC-3 is 11 kW at 400 V, 415 V, 440 V, and 500 V, and 9 kW at 690 V. Dimensions are 45 mm width, 101 mm depth, 86 mm height; net weight 0.39 kg.
- AF38ZB-22-00RT-22
The ABB AF38ZB-22-00RT-22 is a 4-pole AC contactor with 2 NO and 2 NC main contacts and no auxiliary contacts. Its control circuit accepts 48 to 130 V at 50 Hz, 60 Hz, or DC. The main circuit is rated 690 V, with a rated impulse withstand voltage of 6 kV and a conventional free-air thermal current of 55 A according to IEC 60947-4-1 at 40 °C. AC-3 rated operational power is 11 kW at 400 V, 415 V, 440 V, and 500 V, and 9 kW at 690 V. Dimensions are 45 mm wide, 101 mm deep, and 86 mm high, weighing 0.39 kg. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715, or on 2 x M4 screws placed diagonally.