The ABB DS201 M B40 A300 is a leakage protection circuit breaker with a rated current of 40 A and a rated residual current of 300 mA. It has a B tripping characteristic and Type A residual current. Rated operational voltage is 240 V AC according to IEC 60898-1, rated insulation voltage is 500 V according to IEC/EN 60664-1, and rated impulse withstand voltage is 4 kV. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity is 15 kA, and rated service short-circuit breaking capacity is 11.2 kA. It has two poles, one protected pole, and two modular spacings. Power loss is 9.1 W total. Electrical endurance is 10000 cycles and mechanical endurance is 20000 cycles. It mounts on DIN rail.
- DS201 M B40 AC100
The ABB DS201 M B40 AC100 is a 1P+N residual current circuit breaker with overcurrent protection, occupying two DIN-rail module spacings. It has a rated current of 40 A, a rated residual current of 100 mA, Type AC residual current, and a B tripping characteristic. Rated operational voltage is 240 V AC according to IEC 60898-1; rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity is 15 kA, and rated service short-circuit breaking capacity is 11.2 kA. It is rated 50 to 60 Hz, with 4 kV impulse withstand voltage and 2 kV dielectric test voltage. Standards: IEC/EN 61009-1 and IEC/EN 61009-2-1. Electrical endurance is 10000 cycles; mechanical endurance is 20000 cycles. Terminal tightening torque is 2.8 N·m; operating ambient air temperature is -25 to 55 °C.
- DS201 M B40 AC30
The ABB DS201 M B40 AC30 is a DIN-rail mounted leakage protection circuit breaker with one protected pole in a two-pole, two-module configuration. It carries a 40 A rated current, 30 mA rated residual current, Type AC residual current, and B tripping characteristic. Rated operational voltage is 240 V AC according to IEC 60898-1, with rated insulation voltage 500 V per IEC/EN 60664-1 and rated impulse withstand voltage 4 kV. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity 15 kA, and rated service short-circuit breaking capacity 11.2 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. Electrical endurance is 10000 cycles and mechanical endurance 20000 cycles. Dimensions are 35 mm width, 85 mm height, and 69 mm depth, weighing 200 g.
- DS201 M B40 F30
ABB DS201 M B40 F30 leakage protection circuit breaker, 1P+N, with B tripping characteristic and Type F residual current. Rated current 40 A, rated residual current 30 mA, rated frequency 50 to 60 Hz. Rated operational voltage according to IEC 60898-1 is 240 V AC; rated impulse withstand voltage 4 kV. Rated short-circuit capacity 10 kA, rated ultimate short-circuit breaking capacity 15 kA, rated service short-circuit breaking capacity 11.2 kA. Complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. Two-module DIN-rail device, 35 mm wide, 85 mm high, 69 mm deep, 200 g. Screw terminals, tightening torque 2.8 N·m, wire stripping length 12 mm. Operating ambient air temperature -25 to 55 °C. Degree of protection IP20, IP40.
- DS201 M B6 A100
ABB DS201 M B6 A100 is a 1P+N residual current circuit breaker (RCBO) combining overcurrent and earth fault protection in one device. It has a B tripping characteristic, Type A residual current, rated current 6 A, and rated residual current 100 mA. Rated operational voltage is 240 V AC according to IEC 60898-1; rated insulation voltage is 500 V according to IEC/EN 60664-1. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity (Icu) is 15 kA, and rated residual breaking capacity (IΔm) is 6000 A per EN 61009-1 and IEC 61009-1. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. It mounts on DIN rail, has two poles, two modular spacings, screw terminals, and dimensions 35 mm x 85 mm x 69 mm.
- DS201 M B6 A30
The ABB DS201 M B6 A30 is a DIN-rail mounted leakage protection circuit breaker with a B tripping characteristic and Type A residual current detection. It has a rated current of 6 A, a rated residual current of 30 mA, and two poles, one protected. Rated operational voltage is 240 V AC according to IEC 60898-1; rated insulation voltage is 500 V according to IEC/EN 60664-1. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity is 15 kA, and rated service short-circuit breaking capacity is 11.2 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. Electrical endurance is 10000 cycles and mechanical endurance is 20000 cycles. Dimensions are 35 mm wide, 85 mm high, and 69 mm deep, weighing 200 g.
- DS201 M B6 A30 110V
The ABB DS201 M B6 A30 110V is a 1P+N leakage protection circuit breaker with a 6 A rated current and 30 mA rated residual current, Type A. It has a B tripping characteristic and is rated for 240 V AC operation according to IEC 60898-1, with a rated insulation voltage of 500 V per IEC/EN 60664-1 and a 4 kV impulse withstand. Rated short-circuit capacity is 10 kA, with Icu 15 kA and Ics 11.2 kA. It complies with IEC 61009-1 and IEC 61009-2-1. The device mounts on DIN rail, occupies two modular spacings (35 mm wide, 85 mm high, 69 mm deep), weighs 200 g, and operates from -25 to 55 °C.
- DS201 M B6 A300
The ABB DS201 M B6 A300 is a 1P+N leakage protection circuit breaker with a rated current of 6 A and a rated residual current of 300 mA. It has a B tripping characteristic and Type A residual current. Rated operational voltage is 240 V AC according to IEC 60898-1, rated impulse withstand voltage is 4 kV, and rated short-circuit capacity is 10 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. It mounts on DIN rail, occupies two modular spacings, and measures 35 mm wide, 85 mm high, and 69 mm deep. Screw terminals accept conductors from 0.75 to 25 mm², with 2.8 N·m tightening torque. Operating ambient air temperature is -25 to 55 °C.