- AS09-30-32-20
The ABB AS09-30-32-20 is a 3-pole AC contactor with three normally open main contacts and no normally closed main contacts. It provides three normally open and two normally closed auxiliary contacts. The contactor is rated for a 24 V control circuit at 50 Hz and 60 Hz. It measures 45 mm wide, 100.2 mm deep, and 68 mm high, and weighs 0.26 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, with a rated frequency of 50/60 Hz. It uses screw terminals. The device is designated by manufacturer ID 1SBL101001R2032 and complies with IEC 60947-1 / 60947-4-1, EN 60947-1 / 60947-4-1, UL 508, and CSA C22.2 N°14.
- AS09-30-32-25
The ABB AS09-30-32-25 is a 3-pole AC contactor with three normally open main contacts and no normally closed main contacts. It carries three normally open and two normally closed auxiliary contacts. The coil is rated 220 V at 50 Hz and 60 Hz. Rated operational voltage is 690 V for both main and auxiliary circuits at 50/60 Hz. AC-3 rated operational current is 9 A at 380/400 V, 415 V, and 220/230/240 V, and 5 A at 690 V, all at 60 °C. AC-3 rated operational power is 4 kW at 400 V, 415 V, 440 V, 500 V, and 690 V, and 2.2 kW at 220/230/240 V. Terminals are screw type. Dimensions are 45 mm wide, 100.2 mm deep, and 68 mm high; net weight is 0.26 kg. Standards: IEC 60947-1 / 60947-4-1, EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14.
- AS09-30-32-26
The ABB AS09-30-32-26 is an AC contactor with three normally open main contacts and no normally closed main contacts. It provides three normally open and two normally closed auxiliary contacts. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 9 A at 380/400 V and 415 V, 8 A at 440 V and 500 V, and 5 A at 690 V, all at 60 °C. Rated operational power AC-3 is 4 kW at 400 V, 415 V, 440 V, 500 V, and 690 V, and 2.2 kW at 220/230/240 V. The contactor uses screw terminals, measures 45 mm wide, 100.2 mm deep, and 68 mm high, and weighs 0.26 kg. Standards listed are IEC 60947-1 / 60947-4-1, EN 60947-1 / 60947-4-1, UL 508, and CSA C22.2 N°14.
- AS09-30-32S-20
The ABB AS09-30-32S-20 is an AC contactor with three main NO contacts and no main NC contacts, plus three auxiliary NO and two auxiliary NC contacts. It is rated for a main and auxiliary circuit operational voltage of 690 V and a frequency of 50/60 Hz. The control circuit voltage is 24 V at 50 Hz and 60 Hz. Rated operational current AC-3 is 9 A at 220/230/240 V, 380/400 V, and 415 V, and 5 A at 690 V, all at 60 °C. Rated operational power AC-3 is 4 kW at 400 V, 415 V, 440 V, 500 V, and 690 V, and 2.2 kW at 220/230/240 V. Terminals are spring type, IP20, with 10 mm stripping length. Dimensions are 45 mm width, 110.7 mm depth, 68 mm height, and 0.26 kg weight.
- AS09-30-32S-25
ABB AS09-30-32S-25 AC contactor, manufacturer ID 1SBL101004R2532. It has three main contacts NO and no main contacts NC, plus three auxiliary contacts NO and two auxiliary contacts NC. Terminals are spring type, with main, auxiliary, and control circuits accepting rigid or flexible conductors from 0.75 to 2.5 mm² and a 10 mm stripping length. Rated operational voltage is 690 V for main and auxiliary circuits at 50/60 Hz. Rated operational current AC-3 is 9 A at 415 V and 380/400 V, 8 A at 440 V and 500 V, and 5 A at 690 V, all at 60 °C. Rated operational power AC-3 is 4 kW at 400 V, 415 V, 440 V, 500 V, and 690 V, and 2.2 kW at 220/230/240 V. Dimensions are 45 mm wide, 110.7 mm deep, 68 mm high; net weight 0.26 kg.
- AS12-30-01-25
The ABB AS12-30-01-25 is a three-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It has a rated control circuit voltage of 220 V at 50 Hz and 60 Hz. The rated operational current AC-3 is 12 A at 415 V and 60 °C, and the rated operational power AC-3 is 5.5 kW at 400 V. The contactor accepts screw terminals and supports main circuit conductors from 0.75 to 4 mm² rigid. It measures 45 mm wide, 72.5 mm deep, and 68 mm high, and weighs 0.22 kg. It is rated for operation up to 3000 m altitude without derating and conforms to IEC 60947-1, IEC 60947-4-1, UL 508, and CSA C22.2 No. 14.
- AS12-30-01-26
The ABB AS12-30-01-26 is an AC contactor with three normally open main contacts and one normally closed auxiliary contact. It has screw terminals and measures 45 mm wide, 72.5 mm deep, and 68 mm high, weighing 0.22 kg. Rated operational voltage is 690 V for both main and auxiliary circuits at 50/60 Hz. Rated operational current AC-3 is 12 A at 415 V and 60 °C, 11 A at 440 V and 500 V, and 7 A at 690 V. Rated operational power AC-3 is 5.5 kW at 400 V, 415 V, 440 V, 500 V, and 690 V, and 3 kW at 220/230/240 V. Coil voltage is 230 V at 50 Hz and 60 Hz. Standards: IEC 60947-1/60947-4-1, EN 60947-1/60947-4-1, UL 508, CSA C22.2 N°14.
- AS12-30-01S-20
ABB AS12-30-01S-20 AC contactor, manufacturer ID 1SBL111004R2001. Three main contacts NO, zero main contacts NC, one auxiliary contact NC. Rated operational voltage 690 V for main and auxiliary circuits; rated frequency 50/60 Hz for both. Rated operational current AC-3 is 12 A at 415 V and 60 °C, 11 A at 440 V and 500 V, 7 A at 690 V, and 12 A at 220/230/240 V and 380/400 V, all at 60 °C. Rated operational power AC-3 is 5.5 kW at 400 V, 415 V, 440 V, 500 V, and 690 V, and 3 kW at 220/230/240 V. Coil voltage is 24 V at 50 Hz and 60 Hz. Dimensions are 45 mm width, 72.5 mm depth, 68 mm height; weight 0.22 kg. Spring terminals. Standards: IEC 60947-1 / 60947-4-1, EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14.