- DDA204 AC-63/0.03
The ABB DDA204 AC-63/0.03 is a four-pole residual current device block for assembly with S200 series and S300P miniature circuit breakers. It is a Type AC device with a rated residual current of 30 mA and a rated current of 63 A. Rated voltage is 230/400 V at 50 to 60 Hz; rated insulation voltage is 500 V and rated impulse withstand voltage is 4 kV. It is instantaneous in operation and rated for 10000 electrical cycles. Connecting capacity is rigid 25 to 25 mm² and flexible 25 to 25 mm². Ambient operating temperature range is -25 to 55 °C, degree of protection IP2X, power loss 7.6 W. It is declared to IEC/EN 61009 Ann. G.
- DDA204 AC-63/0.03 110V
ABB DDA204 AC-63/0.03 110V leakage protector, manufacturer ID 2CSB204099R1630. Four-pole residual current device, Type AC, rated current 63 A, rated residual current 30 mA, instantaneous operating characteristic. Rated voltage 230...400 V, rated operational voltage 230/400 V, rated insulation voltage 500 V, test voltage 110 V, rated impulse withstand voltage 4 kV, rated frequency 50...60 Hz. Standards: IEC 61009 Ann. G. Power loss 7.6 W, electrical endurance 10000 cycle. Connecting capacity rigid 25...25 mm², flexible 25...25 mm². Ambient temperature -25...55 °C, degree of protection IP2X. Dimensions 140 mm width, 93 mm height, 76 mm depth; net weight 311 g. Suitable for 110 V applications.
- DDA204 AC-63/0.03AP-R
ABB DDA204 AC-63/0.03AP-R leakage protector, manufacturer ID 2CSB204301R1630. Rated operational voltage 230/400 V at rated frequency 50 to 60 Hz. Operating characteristic is instantaneous (APR high immunity). Dimensions are 140 mm width, 93 mm height, and 76 mm depth. Vibration resistance is 20 cycles with load 0.8 In at 1 g or 1 mm, 50 to 150 to 5 Hz. Shock resistance according to IEC 60068-2-27 is 25 g, 2 shocks, 13 ms. ETIM 8 and ETIM 9 classification is EC002297, residual current circuit breaker (RCCB) module. eClass V11.0 is 27142210. No batteries are included.
- DDA204 AC-63/0.1
ABB DDA204 AC-63/0.1 is a 4-pole residual current circuit breaker module with Type AC residual current detection. It has a rated current of 63 A and a rated residual current of 100 mA, with instantaneous operating characteristic. Rated voltage is 230/400 V at 50 to 60 Hz. Rated insulation voltage is 500 V and rated impulse withstand voltage is 4 kV. Power loss is 7.6 W, electrical endurance is 10000 cycles, and connecting capacity accepts rigid or flexible conductors of 25 to 25 mm². Ambient operating temperature range is -25 to 55 °C, degree of protection is IP2X, and net dimensions are 140 mm width, 93 mm height, and 76 mm depth, weighing 311 g. Standards: IEC/EN 61009 Ann. G.
- DDA204 AC-63/0.3
ABB DDA204 AC-63/0.3 leakage protector, manufacturer ID 2CSB204001R3630. Type AC residual current device rated 63 A, 300 mA, 4-pole, instantaneous operating characteristic. Rated voltage 230/400 V, rated insulation voltage 500 V, rated impulse withstand voltage 4 kV, rated frequency 50 to 60 Hz. Power loss 7.6 W; electrical endurance 10000 cycles. Connecting capacity rigid 25 to 25 mm² and flexible 25 to 25 mm². Ambient operating temperature -25 to 55 °C. Degree of protection IP2X. Standards: IEC/EN 61009 Ann. G. Net dimensions 140 mm width, 93 mm height, 76 mm depth; net weight 311 g. Vibration resistance 20 cycles with load 0.8 In at 1 g or 1 mm, 50 to 150 to 5 Hz. Shock resistance per IEC 60068-2-27: 25 g, 2 shocks, 13 ms.
- DDA204 AC-63/0.5
The ABB DDA204 AC-63/0.5 is a four-pole residual current device block for protection against sinusoidal alternating earth fault currents. It is rated 63 A with a rated residual current of 500 mA, Type AC, and operates at 230/400 V, 50 to 60 Hz. Rated insulation voltage is 500 V and rated impulse withstand voltage is 4 kV. It conforms to IEC/EN 61009 Ann. G and has an instantaneous operating characteristic. Electrical endurance is 10000 cycles, power loss is 7.6 W, and connecting capacity is rigid or flexible 25 mm². Ambient operating temperature range is -25 to 55 °C, degree of protection is IP2X, and net dimensions are 140 mm width, 93 mm height, and 76 mm depth, weighing 311 g.
- DDA204 AC-63/1
ABB DDA204 AC-63/1 leakage protector, manufacturer ID 2CSB204001R5630. Type AC residual current device per IEC/EN 61009 Ann. G, four poles, rated current 63 A, rated residual current 1000 mA, instantaneous operating characteristic. Rated voltage 230/400 V, rated insulation voltage 500 V, rated impulse withstand voltage 4 kV, rated frequency 50 to 60 Hz. Power loss 7.6 W, electrical endurance 10000 cycles. Connecting capacity rigid 25 to 25 mm² and flexible 25 to 25 mm². Ambient temperature -25 to 55 °C, degree of protection IP2X. Net dimensions 140 mm width, 93 mm height, 76 mm depth; net weight 311 g. Environmental information: refer to RoHS.
- DDA204 AC-63/2
ABB DDA204 AC-63/2 leakage protector, manufacturer ID 2CSB204001R6630. Type AC residual current device per IEC/EN 61009 Ann. G, rated current 63 A, rated residual current 2000 mA, rated voltage 230/400 V, rated frequency 50 to 60 Hz, four poles, instantaneous operating characteristic. Rated insulation voltage 500 V, rated impulse withstand voltage 4 kV, power loss 7.6 W, electrical endurance 10000 cycles. Connecting capacity rigid 25 to 25 mm² and flexible 25 to 25 mm². Ambient operating temperature -25 to 55 °C, degree of protection IP2X. Dimensions 140 mm width, 93 mm height, 76 mm depth; net weight 311 g. ETIM 8 and ETIM 9 classification EC002297.