- VBC7A-30-01-F-01
The ABB VBC7A-30-01-F-01 is an invertible contactor with three main NO contacts and one auxiliary NC contact. It has a rated control circuit voltage of 24 V DC, with coil operating limits of 0.85 to 1.1 x Uc for DC supply at ambient temperatures up to 55 °C, per IEC 60947-4-1. Rated operational power AC-3 is 5.5 kW at 400 V and 500 V three-phase, and 3 kW at 230 V and 690 V three-phase. Dimensions are 96.2 mm wide, 57.5 mm high, and 46.7 mm deep, weighing 0.345 kg. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715. Main circuit terminals are IP20. Mechanical durability is 10,000,000 cycles. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- VBC7A-30-01-P-01
The ABB VBC7A-30-01-P-01 is a 3-pole invertible contactor with a 24 V DC control circuit. It has three normally open main contacts and one normally closed auxiliary contact. Rated operational power is 3 kW at 230 V three-phase, 5.5 kW at 400 V three-phase, and 5.5 kW at 500 V three-phase. Rated operational current AC-1 is 12 A at 220/240 V and 380/440 V, and 6 A at 690 V. Rated insulation voltage is 690 V, with a rated impulse withstand voltage of 6 kV for the main circuit. Dimensions are 96.2 mm width, 57.5 mm height, and 47.7 mm depth, weighing 0.345 kg. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715. Operating ambient temperature is -20 to +55 degrees C.
- VBC7A-30-10-01
The ABB VBC7A-30-10-01 is a 3-pole invertible contactor with three NO main contacts and one NO auxiliary contact. It measures 96.2 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.355 kg. The main circuit is rated 690 V AC and 220 V DC, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V; 6 A at both temperatures for 690 V. Rated operational power AC-3 is 3 kW at 230 V, 5.5 kW at 400 V and 500 V, and 3 kW at 690 V. The control circuit is 24 V DC. Mechanical durability is 10,000,000 cycles. Ambient operating temperature is -20 to +55 °C.
- VBC7A-30-10-05
The ABB VBC7A-30-10-05 is a 3-pole invertible contactor with three normally open main contacts and one normally open auxiliary contact. Its rated operational voltage is 690 V AC for the main and auxiliary circuits, and 220 V DC for the main circuit; rated frequency is 50 Hz or 60 Hz for the main circuit. Rated operational power AC-3 is 3 kW at 230 V and 5.5 kW at 400 V and 500 V, three phase. The control circuit voltage is 220 to 240 V DC. Dimensions are 96.2 mm wide, 57.5 mm high and 46.7 mm deep, weight 0.355 kg. Main circuit terminals are IP20. It mounts on TH35-15 or TH35-7.5 DIN rail to IEC 60715.
- VBC7A-30-10-16
The ABB VBC7A-30-10-16 is a 3-pole invertible contactor with three normally open main contacts and one normally open auxiliary contact. It measures 96.2 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.355 kg. The main circuit is rated 690 V AC and 220 V DC, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V; 6 A at 690 V for both temperatures. Rated operational power AC-3 is 3 kW at 230 V, 5.5 kW at 400 V and 500 V, and 3 kW at 690 V. The control circuit is 48 V DC. Main terminals are IP20. Mechanical durability is 10,000,000 cycles. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- VBC7A-30-10-P-01
ABB VBC7A-30-10-P-01 invertible contactor with 3 poles, 3 main contacts NO and 1 auxiliary contact NO. Rated operational voltage: main circuit 690 V AC / 220 V DC; auxiliary circuit 690 V AC / 250 V DC. Rated operational current AC-1: 12 A at 220/240 V and 380/440 V (40 °C and 55 °C), 6 A at 690 V. Rated operational power AC-3: 3 kW at 230 V three-phase, 5.5 kW at 400 V and 500 V, 3 kW at 690 V. Coil: 24 V DC, operating limits 0.85 to 1.1 x Uc per IEC 60947-4-1. Dimensions 96.2 x 57.5 x 47.7 mm, 0.345 kg. DIN rail TH35-15 or TH35-7.5 per IEC 60715. Mechanical durability 10,000,000 cycles. Ambient operation -20 to +55 °C.
- VBC7A-30-10-P-2.4
The ABB VBC7A-30-10-P-2.4 is a 3-pole invertible contactor with three normally open main contacts and one normally open auxiliary contact. It has a rated control circuit voltage of 17 to 32 V DC and operates on main circuit frequencies of 50 Hz, 60 Hz, and DC. Rated operational current AC-1 is 12 A at 220/240 V and 380/440 V, and 6 A at 690 V, at both 40 °C and 55 °C. Rated operational power AC-3 is 3 kW at 230 V, 5.5 kW at 400 V, and 5.5 kW at 500 V for three-phase loads. Dimensions are 96.2 mm wide, 57.5 mm high, and 47.7 mm deep, with a net weight of 0.345 kg. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715 and carries IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1 standards. CA6 or CAF6 accessories are not mountable.
- VBC7A-40-00-01
The ABB VBC7A-40-00-01 is a 4-pole mini contactor with four NO main contacts and no NC main or auxiliary contacts. It measures 96.2 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.355 kg. The main circuit is rated 690 V AC and 220 V DC, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V. The control circuit is 24 V DC. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V. AC-3 rated power includes 3 kW at 230 V and 5.5 kW at 400 V and 500 V. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715.