- DDA203 A-63/0.03
The ABB DDA203 A-63/0.03 is a 3-pole residual current device block with Type A residual current detection and instantaneous operating characteristic. It has a rated current of 63 A, rated residual current of 30 mA, and rated voltage of 230/400 V at 50 to 60 Hz. Rated insulation voltage is 500 V and rated impulse withstand voltage is 4 kV. It conforms to IEC/EN 61009 Ann. G. Power loss is 7.6 W, electrical endurance is 10000 cycles, and connecting capacity is rigid 25 to 25 mm² and flexible 25 to 25 mm². Ambient operating temperature range is -25 to 55 °C, with IP2X degree of protection. Dimensions are 122 mm width, 93 mm height, and 76 mm depth; net weight is 311 g.
- DDA203 A-63/0.03 110V
ABB DDA203 A-63/0.03 110V leakage protector, manufacturer ID 2CSB203199R1630. Type A residual current device to IEC 61009 Ann. G, 3-pole, rated current 63 A, rated residual current 30 mA, instantaneous operating characteristic. Rated voltage 230...400 V, rated operational voltage 230/400 V, rated insulation voltage 500 V, test voltage 110 V, rated impulse withstand voltage 4 kV, rated frequency 50...60 Hz. Power loss 7.6 W, electrical endurance 10000 cycles. Connecting capacity rigid 25...25 mm², flexible 25...25 mm². Ambient temperature -25...55 °C, degree of protection IP2X. Net dimensions 122 mm width, 93 mm height, 76 mm depth; net weight 311 g. Suitable for 110 V applications.
- DDA203 A-63/0.03 AE
ABB DDA203 A-63/0.03 AE leakage protector, 3-pole, Type A residual current, rated current 63 A, rated residual current 30 mA. Rated voltage 230/400 V, rated operational voltage 400 V, rated insulation voltage 500 V, rated impulse withstand voltage 4 kV, rated frequency 50 to 60 Hz. Operating characteristic instantaneous (AE for emergency stop); application for emergency stop. Standards: IEC/EN 61009 Ann. G. Electrical endurance 10000 cycles; power loss 7.6 W. Connecting capacity rigid 25 to 25 mm², flexible 25 to 25 mm². Ambient temperature -25 to 55 °C; degree of protection IP2X. Dimensions 122 mm width, 93 mm height, 76 mm depth; net weight 311 g. Manufacturer ID 2CSB203701R1630.
- DDA203 A-63/0.03 AP-R
ABB DDA203 A-63/0.03 AP-R leakage protector, manufacturer ID 2CSB203401R1630. Type A residual current device, 3-pole, rated current 63 A, rated residual current 30 mA, rated voltage 230/400 V, rated frequency 50 to 60 Hz. Rated insulation voltage 500 V, rated impulse withstand voltage 4 kV, maximum surge current 3 kA. Operating characteristic instantaneous (APR high immunity). Standards IEC/EN 61009 Ann. G. Electrical endurance 10000 cycles, power loss 7.6 W. Connecting capacity rigid 25 to 25 mm², flexible 25 to 25 mm². Ambient temperature -25 to 55 °C, degree of protection IP2X. Dimensions 122 mm width, 93 mm height, 76 mm depth, net weight 311 g.
- DDA203 A-63/0.1
ABB DDA203 A-63/0.1 leakage protector, manufacturer ID 2CSB203101R2630. Three-pole device rated 63 A with 100 mA rated residual current, Type A residual current, and instantaneous operating characteristic. Rated voltage 230/400 V, rated insulation voltage 500 V, rated impulse withstand voltage 4 kV, rated frequency 50 to 60 Hz. Power loss 7.6 W; electrical endurance 10000 cycles. Connecting capacity for rigid and flexible conductors 25 to 25 mm². Ambient operating temperature -25 to 55 °C, degree of protection IP2X. Standards: IEC/EN 61009 Ann. G. Net dimensions 122 mm width, 93 mm height, 76 mm depth; net weight 311 g.
- DDA203 A-63/0.3
ABB DDA203 A-63/0.3 is a 3-pole residual current device classified as a leakage protector. It is a Type A device with a rated residual current of 300 mA and a rated current of 63 A. Rated voltage is 230/400 V at 50 to 60 Hz, with rated insulation voltage 500 V and rated impulse withstand voltage 4 kV. It conforms to IEC/EN 61009 Ann. G. Operating characteristic is instantaneous, electrical endurance is 10000 cycles, and power loss is 7.6 W. Connecting capacity is rigid 25 to 25 mm² and flexible 25 to 25 mm². Ambient operating temperature is -25 to 55 °C, degree of protection is IP2X, and net dimensions are 122 mm width, 93 mm height, 76 mm depth, 311 g weight.
- DDA203 A-63/0.3 AE
The ABB DDA203 A-63/0.3 AE is a three-pole residual current circuit breaker for emergency stop applications. It is Type A, responding to sinusoidal alternating and pulsating direct residual currents, with a rated residual current of 300 mA and rated current of 63 A. Rated voltage is 230/400 V, rated operational voltage 400 V, rated insulation voltage 500 V, and rated impulse withstand voltage 4 kV. Rated frequency is 50 to 60 Hz, power loss 7.6 W, and electrical endurance 10000 cycles. The operating characteristic is instantaneous (AE for emergency stop). Standards: IEC/EN 61009 Ann. G. Connecting capacity is rigid 25 to 25 mm² and flexible 25 to 25 mm². Ambient operating temperature is -25 to 55 °C, degree of protection IP2X. Dimensions are 122 mm width, 93 mm height, 76 mm depth; net weight 311 g.
- DDA203 A-63/0.5
ABB DDA203 A-63/0.5 leakage protector, 3-pole, Type A residual current device. Rated current 63 A, rated residual current 500 mA, rated voltage 230/400 V, rated frequency 50 to 60 Hz, instantaneous operating characteristic. Complies with IEC/EN 61009 Ann. G. Rated insulation voltage 500 V, rated impulse withstand voltage 4 kV, power loss 7.6 W, electrical endurance 10000 cycles. Connecting capacity 25 mm² rigid and 25 mm² flexible. Ambient operating temperature -25 to 55 °C, degree of protection IP2X. Dimensions 122 mm width, 93 mm height, 76 mm depth; net weight 311 g. Manufacturer ID 2CSB203101R4630.