- BC6-31-00-16
The ABB BC6-31-00-16 is a 4-pole mini contactor with 3 NO and 1 NC main contacts and no auxiliary contacts. It measures 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.175 kg. The main circuit is rated 690 V AC and 220 V DC, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 4 kW at 400 V and 500 V three-phase. The control circuit is 48 V DC. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715.
- BC6-40-00-01
ABB BC6-40-00-01 mini contactor, 4-pole with four normally open main contacts and no auxiliary contacts. Main circuit rated operational voltage is 690 V AC and 220 V DC; rated insulation voltage is 690 V per UL/CSA and 600 V. Rated impulse withstand voltage is 6 kV. The DC control circuit is rated 24 V DC with coil operating limits of 0.85 to 1.1 x Uc per IEC 60947-4-1 at ambient temperatures up to 55 °C. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 40 °C and 55 °C for 690 V. AC-3 rated power includes 4 kW at 400 V three-phase. Dimensions are 52.5 mm width, 57.5 mm height, 46.7 mm depth; net weight 0.175 kg.
- BC6-40-00-03
The ABB BC6-40-00-03 is a 4-pole mini contactor with four normally open main contacts and no auxiliary contacts. It measures 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.175 kg. The main circuit is rated 690 V AC and 220 V DC, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V. Rated operational power AC-3 is 2.2 kW at 230 V three-phase, 4 kW at 400 V and 500 V three-phase, and 3 kW at 690 V three-phase. The control circuit is 60 V DC. Coil operating limits are 0.85 to 1.1 x Uc for DC supply at temperatures up to 55 degrees C. Terminal protection is IP20.
- BC6-40-00-04
The ABB BC6-40-00-04 is a 4-pole mini contactor with four normally open main contacts and no auxiliary contacts. The control circuit is rated 110 to 125 V DC, with coil operating limits of 0.85 to 1.1 x Uc according to IEC 60947-4-1 for DC supply at ambient temperatures up to 55 °C. Main circuit ratings include 690 V AC and 220 V DC, with a rated impulse withstand voltage of 6 kV and a conventional free-air thermal current of 20 A. AC-3 rated operational power is 4 kW at 400 V and 500 V three-phase, and 3 kW at 690 V three-phase. Dimensions are 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, weighing 0.175 kg. Screw terminals accept rigid conductors from 1 to 4 mm². Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- BC6-40-00-05
ABB BC6-40-00-05 mini contactor with four normally open main contacts and no normally closed main or auxiliary contacts. Main circuit rated operational voltage is 690 V AC and 220 V DC; rated insulation voltage is 690 V, 600 V according to UL/CSA. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at both 40 °C and 55 °C for 690 V. Rated operational power AC-3 is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V, three-phase. Control circuit voltage is 220 to 240 V DC. Dimensions are 52.5 mm wide, 57.5 mm high, and 46.7 mm deep; net weight 0.175 kg.
- BC6-40-00-1.4-81
The ABB BC6-40-00-1.4-81 is a 4-pole interface mini contactor with four normally open main contacts and no auxiliary contacts. It measures 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.175 kg. The control circuit is rated 24 V DC; coil operating limits are 0.85 to 1.1 x Uc for DC supply at ambient temperatures up to 55 °C. Main circuit ratings include 690 V AC and 220 V DC, with a rated impulse withstand voltage of 6 kV. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V. Screw terminals accept rigid conductors from 1 to 4 mm². Standards include IEC/EN 60947-4-1, IEC/EN 60947-5-1, and UL 60947-4-1. No CA6 or CAF6 mountable.
- BC6-40-00-16
The ABB BC6-40-00-16 is a 4-pole mini contactor with four normally open main contacts and no auxiliary contacts. Its control circuit is rated 48 V DC; the main circuit is rated 690 V AC and 220 V DC, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C at 220/240 V and 380/440 V, and 6 A at 690 V. AC-3 rated operational power is 4 kW at 400 V and 500 V three-phase. Dimensions are 52.5 mm wide, 57.5 mm high, and 46.7 mm deep; net weight 0.175 kg. Terminals are IP20, with 9 mm main-circuit stripping length and 0.8 to 1.1 N·m tightening torque. Standards include IEC/EN 60947-4-1 and UL 60947-4-1.
- BC6-40-00-F-01
The ABB BC6-40-00-F-01 is a miniature AC contactor with four poles and four normally open main contacts. It has a rated control circuit voltage of 24 V DC and a rated operational voltage of 690 V AC for the main circuit and 220 V DC. Rated operational current AC-1 is 20 A at 220/240 V and 380/440 V at 40 °C, and 6 A at 690 V at 40 °C. Rated operational power AC-3 is 4 kW at 400 V and 500 V three-phase. Dimensions are 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, with a net weight of 0.17 kg. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715.