- KC6-22E-1.4-81
ABB KC6-22E-1.4-81 interface mini contactor relay with 4 poles, 2 NO and 2 NC auxiliary contacts, and no main contacts. Coil rated 24 V DC, average pull-in and holding 1.4 W; coil operating limits 0.85 to 1.1 x Uc for DC supply at up to 55 °C. Rated operational current AC-15: 4 A at 24, 120 and 240 V, 3 A at 400 V, 2 A at 500 V; DC-13: 2.5 A at 24 V, 0.7 A at 110 V, 0.4 A at 220/240 V. Screw terminals, DIN-rail mounting per IEC 60715, IP20 terminals, mechanical durability 10,000,000 cycles, ambient operation -25 to +55 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L. Dimensions 52.5 x 46.5 x 57.5 mm; weight 0.175 kg.
- KC6-22Z 110-125V DC
ABB KC6-22Z 110-125V DC is an industrial catalog item. Key specifications include Manufacturer: ABB, Type of contactor: 4-pole, Contacts configuration: NC x2 + NO x2, and Control voltage: 17...32V DC. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- KC6-22Z-01
ABB KC6-22Z-01 is a 4-pole mini contactor relay with 2 NO and 2 NC auxiliary contacts and screw terminals. The coil is rated 24 V DC, with average pull-in and holding consumption of 3.5 W each; coil operating limits are 0.85 to 1.1 x Uc for DC supply at temperatures up to 55 °C. Dimensions are 52.5 mm wide, 46.5 mm deep and 57.5 mm high, weighing 0.175 kg. DIN-rail mounting uses TH35-15 or TH35-7.5 rail according to IEC 60715. Rated insulation voltage is 690 V, rated impulse withstand voltage 6 kV, and conventional free-air thermal current 6 A. Mechanical durability is 10,000,000 cycles. Ambient operating temperature range is -25 to +55 °C.
- KC6-22Z-02
ABB KC6-22Z-02 intermediate relay, mini contactor relay type, 4-pole with 2 NO and 2 NC auxiliary contacts and no main contacts. Rated control circuit voltage is 42 V DC; coil consumption is average pull-in and holding 3.5 W DC. Coil operating limits per IEC 60947-5-1 for DC supply are 0.85 to 1.1 x Uc at temperatures up to 55 °C. Screw terminals accept rigid 1 to 4 mm² and flexible 1 to 2.5 mm² conductors; tightening torque is 0.8 to 1.1 N·m. DIN-rail mounting per IEC 60715 on TH35-15 or TH35-7.5 rail. Dimensions are 52.5 mm width, 46.5 mm depth, 57.5 mm height; net weight 0.175 kg. Mechanical durability is 10,000,000 cycles. Ambient operating temperature is -25 to +55 °C.
- KC6-22Z-04
The ABB KC6-22Z-04 is a 4-pole mini contactor relay with screw terminals and four auxiliary contacts, two normally open and two normally closed. Its coil is rated 110 to 125 V DC, with average pull-in and holding consumption of 3.5 W each; coil operating limits are 0.85 to 1.1 x Uc for DC supply according to IEC 60947-5-1 at ambient temperatures up to 55 °C. Rated insulation voltage is 690 V, and rated impulse withstand voltage for the auxiliary circuit is 6 kV. The device measures 52.5 mm wide, 46.5 mm deep, and 57.5 mm high, weighs 0.175 kg, mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715, and operates from -25 to +55 °C at altitudes up to 2000 m. Mechanical durability is 10,000,000 cycles. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- KC6-22Z-05
The ABB KC6-22Z-05 is a 4-pole mini contactor relay with 2 NO and 2 NC auxiliary contacts and no main contacts. It uses screw terminals and mounts on TH35-15 (35 x 15 mm) or TH35-7.5 (35 x 7.5 mm) DIN rail per IEC 60715. The coil is rated 220 to 240 V DC, with average pull-in and holding consumption of 3.5 W each. Coil operating limits are 0.85 to 1.1 x Uc for DC supply at temperatures up to 55 degrees C, per IEC 60947-5-1. Dimensions are 52.5 mm wide, 46.5 mm deep, and 57.5 mm high, weighing 0.175 kg. Mechanical durability is 10,000,000 cycles.
- KC6-22Z-07
ABB KC6-22Z-07 mini contactor relay, manufacturer ID GJH1213001R0227. Four-pole relay with 2 NO and 2 NC auxiliary contacts, no main contacts. Coil rated 12 V DC; average pull-in and holding consumption 3.5 W each. Coil operating limits per IEC 60947-5-1 for DC supply are 0.85 to 1.1 x Uc at up to 55 °C. Rated operational current AC-15: 4 A at 24, 120 and 240 V, 3 A at 400 V, 2 A at 500 V; DC-13: 2.5 A at 24 V, 0.7 A at 110 V, 0.4 A at 220/240 V. Screw terminals, DIN-rail mounting per IEC 60715. Dimensions 52.5 x 46.5 x 57.5 mm, 0.175 kg. Mechanical durability 10,000,000 cycles. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1.
- KC6-22Z-1.4-81
ABB interface mini contactor relay, display model KC6-22Z-1.4-81, manufacturer ID GJH1213001R8221. Four-pole relay with 2 NO and 2 NC auxiliary contacts and no main contacts. Coil rated 24 V DC; average pull-in and holding consumption 1.4 W each. Coil operating limits per IEC 60947-5-1 for DC supply are 0.85 to 1.1 x Uc at up to 55 °C. Rated operational current AC-15: 4 A at 24, 120 and 240 V, 3 A at 400 V, 2 A at 500 V; DC-13: 2.5 A at 24 V, 0.7 A at 110 V, 0.4 A at 220/240 V. Mechanical durability 10,000,000 cycles. Screw terminals, DIN-rail mounting per IEC 60715. Dimensions 52.5 x 46.5 x 57.5 mm, 0.175 kg. Ambient operation -25 to +55 °C.