- DDA804 A S-100/0.3
The ABB DDA804 A S-100/0.3 is a four-pole residual current device block for use with S800S, S800N, S800C, and S800B circuit breakers. It is a Type A residual current device with a rated residual current of 300 mA and a rated current of 100 A, operating at 50 to 60 Hz. Rated operational voltage is 400/690 V AC, rated insulation voltage is 690 V, and rated impulse withstand voltage is 6 kV. Maximum surge current is 5 kA. The operating characteristic is selective. Power loss is 10.5 W. Connecting capacity is 6 to 50 mm² rigid and 6 to 70 mm² flexible. Ambient operating temperature is -25 to 60 °C. Degree of protection is IP2X. Standards: IEC EN 60947-2 Ann. B. Net dimensions are 117 mm width, 108.2 mm height, and 82.3 mm depth; net weight is 460 g.
- DDA804 A S-100/0.5
The ABB DDA804 A S-100/0.5 is a selective residual current device block for assembly with S800S, S800N, S800C, and S800B miniature circuit breakers. It is a four-pole Type A device with a rated current of 100 A and a rated residual current of 500 mA, responding to sinusoidal alternating and pulsating direct earth fault currents. Rated operational voltage is 400/690 V AC, rated insulation voltage 690 V, rated impulse withstand voltage 6 kV, and rated frequency 50 to 60 Hz. Maximum surge current is 5 kA and power loss is 10.5 W. The selective operating characteristic provides an intentional tripping delay. It conforms to IEC EN 60947-2 Ann. B. Connection accepts rigid 6 to 50 mm² or flexible 6 to 70 mm² conductors. Ambient operating temperature is -25 to 60 °C, degree of protection IP2X.
- DDA804 A S-100/1
ABB DDA804 A S-100/1 leakage protector, manufacturer ID 2CSB804201R5000. Type A residual current device, rated current 100 A, rated residual current 1000 mA, selective operating characteristic, 4 poles. Rated operational voltage 400/690 V; rated insulation voltage 690 V; rated impulse withstand voltage 6 kV; rated frequency 50 to 60 Hz; maximum surge current 5 kA; power loss 10.5 W. Standards: IEC EN 60947-2 Ann. B. Suitable for S800S, S800N, S800C and S800B. Connecting capacity: rigid 6 to 50 mm², flexible 6 to 70 mm². Ambient operating temperature -25 to 60 °C. Degree of protection IP2X. Dimensions 117 mm width, 108.2 mm height, 82.3 mm depth; net weight 460 g.
- DDA804 A-100/0.3
The ABB DDA804 A-100/0.3 is a Type A residual current device block for use with S800S, S800N, S800C, and S800B circuit breakers. It has a rated current of 100 A, a rated residual current of 300 mA, and an instantaneous operating characteristic. Rated voltage is 230/400 V AC, 240/415 V AC, and 400/690 V AC, with a rated operational voltage of 400/690 V, rated insulation voltage of 690 V, and rated impulse withstand voltage of 6 kV. Rated frequency is 50 to 60 Hz, maximum surge current is 0.25 kA, and power loss is 10.5 W. It has four poles, IP2X protection, and a manufacturer ID of 2CSB804101R3000. Standards: IEC EN 60947-2 Ann. B.
- DDA804 A-100/0.5
ABB DDA804 A-100/0.5 is a four-pole modular residual current device with a rated current of 100 A and rated residual current of 500 mA. It is Type A to IEC EN 60947-2 Ann. B, rated 400/690 V AC operational, 690 V insulation, 6 kV impulse withstand, 50 to 60 Hz. Maximum surge current is 0.25 kA and power loss is 10.5 W. It is suitable for S800S, S800N, S800C and S800B. Connecting capacity is rigid 6 to 50 mm² and flexible 6 to 70 mm². Ambient operating temperature is -25 to 60 °C, degree of protection IP2X. Dimensions are 117 mm width, 108.2 mm height, 82.3 mm depth, 460 g.
- DDA804 A-63/0.03
ABB DDA804 A-63/0.03 leakage protector module, Type A residual current device. Rated current 63 A, rated residual current 30 mA, instantaneous operating characteristic, four poles. Rated operational voltage 400/690 V, rated insulation voltage 690 V, rated impulse withstand voltage 6 kV, rated frequency 50 to 60 Hz. Maximum surge current 0.25 kA. Power loss 13.5 W. Connecting capacity: rigid 6 to 50 mm², flexible 6 to 70 mm². Ambient operating temperature -25 to 60 °C. Degree of protection IP2X. Standards: IEC EN 60947-2 Ann. B. Suitable for S800S, S800N, S800C, and S800B. Dimensions 117 mm width, 108.2 mm height, 82.3 mm depth; net weight 460 g. Manufacturer ID 2CSB804101R1630.
- DDA804 AC-100/0.03
ABB DDA804 AC-100/0.03 leakage protector, 4-pole, rated current 100 A, rated residual current 30 mA, Type AC residual current, instantaneous operating characteristic. Rated operational voltage 400/690 V; rated insulation voltage 690 V; rated impulse withstand voltage 6 kV; rated frequency 50 to 60 Hz. Maximum surge current 0.25 kA; power loss 10.5 W. Conforms to IEC EN 60947-2 Ann. B. Suitable for S800S, S800N, S800C and S800B. Connecting capacity: rigid 6 to 50 mm2, flexible 6 to 70 mm2. Ambient operating temperature -25 to 60 degrees C. Degree of protection IP2X. Dimensions 117 mm width, 108.2 mm height, 82.3 mm depth; net weight 460 g. Width 6.5 modular spacings.
- DDA804 AC-100/0.3
ABB DDA804 AC-100/0.3 leakage protector block, manufacturer ID 2CSB804001R3100. Type AC residual current device, 4-pole, rated current 100 A, rated residual current 300 mA, instantaneous operating characteristic. Rated operational voltage 400/690 V; rated insulation voltage 690 V; rated impulse withstand voltage 6 kV; rated frequency 50 to 60 Hz. Maximum surge current 0.25 kA; power loss 10.5 W. Standards: IEC EN 60947-2 Ann. B. Suitable for S800S, S800N, S800C and S800B. Connecting capacity rigid 6 to 50 mm², flexible 6 to 70 mm². Ambient operating temperature -25 to 60 °C. Degree of protection IP2X. Dimensions 117 mm width, 108.2 mm height, 82.3 mm depth; net weight 460 g.