- DDA202 A-40/0.3
ABB DDA202 A-40/0.3 is a 2-pole residual current device with a rated current of 40 A and rated residual current of 300 mA. It is Type A, intended for residual currents of type A, with a rated voltage of 230/400 V and rated operational voltage of 230 V. Rated frequency is 50 to 60 Hz; operating characteristic is instantaneous. Rated insulation voltage is 500 V and rated impulse withstand voltage is 4 kV. Power loss is 3.2 W and electrical endurance is 10000 cycle. Connecting capacity is rigid 25 to 25 mm² and flexible 25 to 25 mm². Ambient temperature is -25 to 55 °C. Degree of protection is IP2X. Standards: IEC/EN 61009 Ann. G. Net dimensions are 70 mm width, 93 mm height, 76 mm depth; net weight 210 g.
- DDA202 A-40/0.5
ABB DDA202 A-40/0.5 leakage protector, Type A residual current device, 2-pole, rated current 40 A, rated residual current 500 mA, instantaneous operating characteristic. Rated voltage 230/400 V, rated operational voltage 230 V, rated insulation voltage 500 V, rated impulse withstand voltage 4 kV, rated frequency 50 to 60 Hz. Conforms to IEC/EN 61009 Ann. G. Power loss 3.2 W, electrical endurance 10000 cycles. Connecting capacity rigid 25 to 25 mm² and flexible 25 to 25 mm². Ambient operating temperature -25 to 55 °C, degree of protection IP2X. Dimensions 70 mm width, 93 mm height, 76 mm depth; net weight 210 g. Manufacturer ID 2CSB202101R4400.
- DDA202 A-40/1
The ABB DDA202 A-40/1 is a two-pole residual current device block with a rated current of 40 A and a rated residual current of 1000 mA. It uses Type A residual current detection and operates instantaneously. Rated voltage is 230/400 V, rated operational voltage 230 V, rated insulation voltage 500 V, and rated impulse withstand voltage 4 kV. Rated frequency is 50 to 60 Hz, power loss is 3.2 W, and electrical endurance is 10000 cycles. It conforms to IEC/EN 61009 Ann. G. Connecting capacity is rigid 25 to 25 mm² and flexible 25 to 25 mm². Ambient operating temperature is -25 to 55 °C, degree of protection is IP2X, and net dimensions are 70 mm width, 93 mm height, and 76 mm depth, with a net weight of 210 g.
- DDA202 A-63/0.03
ABB DDA202 A-63/0.03 leakage protector, manufacturer ID 2CSB202101R1630. Type A residual current device, 2-pole, rated current 63 A, rated residual current 30 mA, instantaneous operating characteristic. Rated voltage 230/400 V, rated operational voltage 230 V, rated insulation voltage 500 V, rated impulse withstand voltage 4 kV, rated frequency 50 to 60 Hz. Standards: IEC/EN 61009 Ann. G. Power loss 5 W, electrical endurance 10000 cycles. Connecting capacity rigid 25 to 25 mm² and flexible 25 to 25 mm². Ambient temperature -25 to 55 °C. Degree of protection IP2X. Dimensions 70 mm width, 93 mm height, 76 mm depth; net weight 210 g. ETIM class EC002297.
- DDA202 A-63/0.03 110V
ABB DDA202 A-63/0.03 110V residual current device block, manufacturer ID 2CSB202199R1630. Type A residual current, rated current 63 A, rated residual current 30 mA, two poles, instantaneous operating characteristic. Rated voltage 230 V, rated insulation voltage 500 V, rated impulse withstand voltage 4 kV, test voltage 110 V, rated frequency 50 to 60 Hz. Power loss 5 W, electrical endurance 10000 cycles. Standards: IEC 61009 Ann. G. Connecting capacity rigid 25 mm² and flexible 25 mm². Ambient temperature -25 to 55 °C, degree of protection IP2X. Dimensions 70 mm width, 93 mm height, 76 mm depth; net weight 360 g. Suitable for 110 V applications.
- DDA202 A-63/0.03 400V
ABB DDA202 A-63/0.03 400V leakage protector, Type A residual current device, 2-pole, rated current 63 A and rated residual current 30 mA. Rated operational voltage 230 V; rated insulation voltage 500 V; rated impulse withstand voltage 4 kV; test voltage 400 V. Rated frequency 50 to 60 Hz. Instantaneous operating characteristic, electrical endurance 10000 cycles, power loss 5 W. Conforms to IEC 61009 Ann. G. Connecting capacity rigid and flexible 25 mm². Ambient operating temperature -25 to 55 °C, degree of protection IP2X. Dimensions 70 mm width, 93 mm height, 76 mm depth; net weight 210 g. Manufacturer ID 2CSB202192R1630.
- DDA202 A-63/0.03 AE
ABB DDA202 A-63/0.03 AE leakage protector, manufacturer ID 2CSB202701R1630. It is a 2-pole residual current device with Type A residual current, rated current 63 A, rated residual current 30 mA, and rated voltage 230/400 V. Rated operational voltage is 230 V, rated insulation voltage 500 V, and rated impulse withstand voltage 4 kV. Rated frequency is 50 to 60 Hz. The operating characteristic is instantaneous (AE for emergency stop), and the application is for emergency stop. It conforms to IEC/EN 61009 Ann. G. Electrical endurance is 10000 cycles, power loss 5 W, degree of protection IP2X, and ambient operating temperature -25 to 55 °C. Dimensions are 70 mm width, 93 mm height, 76 mm depth, and net weight 210 g.
- DDA202 A-63/0.03 AP-R
ABB DDA202 A-63/0.03 AP-R is a Type A residual current device block for assembly with S200 series MCBs. It is rated 63 A, 30 mA, 2-pole, with rated voltage 230/400 V and rated operational voltage 230 V, rated frequency 50 to 60 Hz. Rated insulation voltage is 500 V and rated impulse withstand voltage is 4 kV. Maximum surge current is 3 kA, power loss 5 W, and electrical endurance 10000 cycles. Operating characteristic is instantaneous (APR high immunity). Connecting capacity is rigid 25 to 25 mm² and flexible 25 to 25 mm². Ambient temperature range is -25 to 55 °C, degree of protection IP2X. Standards: IEC/EN 61009 Ann. G.