- DDA203 AC-40/0.1
ABB DDA203 AC-40/0.1 leakage protector, 3-pole, rated current 40 A, rated residual current 100 mA, Type AC residual current, instantaneous operating characteristic. Rated voltage 230/400 V, rated insulation voltage 500 V, rated impulse withstand voltage 4 kV, rated frequency 50 to 60 Hz. Power loss 4.8 W, electrical endurance 10000 cycles. Connecting capacity rigid 16 to 16 mm² and flexible 16 to 16 mm². Ambient temperature -25 to 55 °C, degree of protection IP2X. Standards: IEC/EN 61009 Ann. G. Net dimensions 87 mm width, 93 mm height, 76 mm depth; net weight 158 g. Manufacturer ID 2CSB203001R2400.
- DDA203 AC-40/1
ABB DDA203 AC-40/1 is a residual current device block, identified by manufacturer ID 2CSB203001R5400. It is a Type AC device with a rated residual current of 1000 mA, rated current of 40 A, and rated voltage of 230/400 V at 50 to 60 Hz. It has three poles and an instantaneous operating characteristic. Rated insulation voltage is 500 V and rated impulse withstand voltage is 4 kV. It conforms to IEC/EN 61009 Ann. G. Power loss is 4.8 W and electrical endurance is 10000 cycles. Connecting capacity is rigid 16 to 16 mm² and flexible 16 to 16 mm². Dimensions are 87 mm width, 93 mm height, and 76 mm depth; net weight is 158 g. Ambient operating temperature range is -25 to 55 °C, and degree of protection is IP2X.
- DDA203 AC-63/0.03
ABB DDA203 AC-63/0.03 leakage protector, manufacturer ID 2CSB203001R1630. Type AC residual current device per IEC/EN 61009 Ann. G, rated current 63 A, rated residual current 30 mA, three poles, instantaneous operating characteristic. Rated voltage 230/400 V, rated insulation voltage 500 V, rated impulse withstand voltage 4 kV, rated frequency 50 to 60 Hz. Power loss 7.6 W, electrical endurance 10000 cycles. Connecting capacity rigid 25 to 25 mm² and flexible 25 to 25 mm². Ambient temperature -25 to 55 °C. Degree of protection IP2X. Dimensions 122 mm width, 93 mm height, 76 mm depth; net weight 311 g. ETIM class EC002297 residual current circuit breaker module.
- DDA203 AC-63/0.1
The ABB DDA203 AC-63/0.1 is a 3-pole residual current device block with a rated residual current of 100 mA and a rated current of 63 A. It is Type AC, responding to sinusoidal alternating residual currents, and operates instantaneously. Rated voltage is 230/400 V at 50 to 60 Hz, with rated insulation voltage 500 V and rated impulse withstand voltage 4 kV. It conforms to IEC/EN 61009 Ann. G. Power loss is 7.6 W, electrical endurance is 10000 cycles, and connecting capacity is rigid or flexible 25 mm². Ambient operating temperature is -25 to 55 °C, degree of protection is IP2X, and net dimensions are 122 mm width, 93 mm height, and 76 mm depth, weighing 311 g.
- DDA203 AC-63/0.3
ABB DDA203 AC-63/0.3 leakage protector, 3-pole, Type AC residual current device rated 63 A with 300 mA rated residual current. Rated voltage 230/400 V, rated insulation voltage 500 V, rated impulse withstand voltage 4 kV, rated frequency 50 to 60 Hz. Complies with IEC/EN 61009 Ann. G. Instantaneous operating characteristic, electrical endurance 10000 cycles, power loss 7.6 W. Connecting capacity rigid 25 to 25 mm² and flexible 25 to 25 mm². Ambient operating temperature -25 to 55 °C, degree of protection IP2X. Dimensions 122 mm width, 93 mm height, 76 mm depth; net weight 311 g. Manufacturer ID 2CSB203001R3630.
- DDA203 AC-63/0.5
ABB DDA203 AC-63/0.5 is a 3-pole residual current device with Type AC residual current, rated current 63 A and rated residual current 500 mA. Rated voltage is 230/400 V at 50 to 60 Hz; rated insulation voltage is 500 V and rated impulse withstand voltage is 4 kV. It conforms to IEC/EN 61009 Ann. G. Operating characteristic is instantaneous. Electrical endurance is 10000 cycles, power loss 7.6 W. Connecting capacity accepts rigid or flexible conductors of 25 mm². Ambient operating temperature range is -25 to 55 °C, degree of protection IP2X. Dimensions are 122 mm width, 93 mm height and 76 mm depth; net weight 311 g. Manufacturer ID 2CSB203001R4630.
- DDA203 AC-63/1
The ABB DDA203 AC-63/1 is a 3-pole residual current device with Type AC residual current sensing, rated 63 A and 1000 mA residual current. It is rated 230/400 V, 50 to 60 Hz, with rated insulation voltage 500 V and rated impulse withstand voltage 4 kV. It conforms to IEC/EN 61009 Ann. G. The device has an instantaneous operating characteristic, 10000-cycle electrical endurance, and 7.6 W power loss. Connections accept rigid or flexible conductors of 25 to 25 mm². It operates from -25 to 55 °C, has IP2X protection, and measures 122 mm wide, 93 mm high, and 76 mm deep, weighing 311 g.
- DDA203 AC-63/2
ABB DDA203 AC-63/2 leakage protector, manufacturer ID 2CSB203001R6630. Type AC residual current device rated 63 A with rated residual current 2000 mA, rated voltage 230/400 V, rated insulation voltage 500 V, and rated impulse withstand voltage 4 kV. Rated frequency 50 to 60 Hz. Three poles, instantaneous operating characteristic, power loss 7.6 W, electrical endurance 10000 cycles. Connecting capacity for rigid and flexible conductors 25 to 25 mm². Ambient operating temperature -25 to 55 °C, degree of protection IP2X. Standards: IEC/EN 61009 Ann. G. Net dimensions 122 mm width, 93 mm height, 76 mm depth; net weight 311 g.