- B6-30-01-80
The ABB B6-30-01-80 is a 3-pole miniature AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.175 kg. The control circuit voltage is 220 to 240 V AC, with coil operating limits of 0.85 to 1.1 times Uc according to IEC 60947-4-1 at ambient temperatures up to 55 °C. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V. Rated operational power AC-3 is 4 kW at 400 V and 500 V. Mechanical durability is 10,000,000 cycles. Terminal protection is IP20. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- B6-30-01-84
ABB B6-30-01-84 mini contactor, 3-pole, with 3 NO main contacts and 1 NC auxiliary contact. Rated control circuit voltage 110 to 127 V AC, with coil operating limits of 0.85 to 1.1 x Uc at up to 55 °C per IEC 60947-4-1. Rated operational power AC-3 is 4 kW at 400 V three-phase and 3 kW at 690 V three-phase. Rated operational voltage is 690 V AC for main and auxiliary circuits. Dimensions are 52.5 mm wide, 57.5 mm high, and 46.7 mm deep; net weight 0.175 kg. Mounting is on TH35-15 or TH35-7.5 DIN rail per IEC 60715. Screw terminals accept rigid conductors 1 to 4 mm² and flexible conductors 1 to 2.5 mm². Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- B6-30-01-85
ABB B6-30-01-85 mini contactor, manufacturer ID GJL1211001R8015. Three-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. Rated operational voltage: main circuit 690 V AC / 220 V DC; auxiliary circuit 690 V AC / 250 V DC. Rated control circuit voltage 380 to 415 V AC. Rated operational power AC-3: 2.2 kW at 230 V, 4 kW at 400 V and 500 V, 3 kW at 690 V, three-phase. Rated operational current AC-1: 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V; 6 A at 690 V. Dimensions 52.5 x 57.5 x 46.7 mm, 0.175 kg. Screw terminals, IP20. DIN rail mounting per IEC 60715. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1.
- B6-30-01-F-01
ABB mini contactor B6-30-01-F-01, manufacturer ID GJL1211003R0011. Three-pole device with three normally open main contacts and one normally closed auxiliary contact. Rated control circuit voltage is 24 V AC; coil operating limits per IEC 60947-4-1 for AC supply are 0.85 to 1.1 x Uc at ambient temperatures up to 55 °C. Rated operational voltage is 690 V AC for main and auxiliary circuits, 220 V DC main and 250 V DC auxiliary. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V at both temperatures. Rated operational power AC-3 is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V. Dimensions 52.5 x 57.5 x 46.7 mm, 0.17 kg.
- B6-30-01-F-02
ABB miniature AC contactor B6-30-01-F-02, manufacturer ID GJL1211003R0012. Three-pole (3P) mini contactor with three normally open main contacts and one normally closed auxiliary contact. Rated control circuit voltage is 42 V AC; coil operating limits per IEC 60947-4-1 for AC supply are 0.85 to 1.1 x Uc at ambient temperatures up to 55 °C. Rated operational power AC-3 is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V, three phase. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V. Dimensions are 52.5 mm width, 57.5 mm height, and 46.7 mm depth; net weight 0.17 kg. DIN rail mounting per IEC 60715. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1.
- B6-30-01-F-03
The ABB B6-30-01-F-03 is a 3-pole mini contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.17 kg. The control circuit is rated 48 V AC; coil operating limits are 0.85 to 1.1 x Uc for AC supply at ambient temperatures up to 55 °C, per IEC 60947-4-1. Main circuit ratings include 20 A AC-1 at 40 °C and 4 kW AC-3 at 400 V three-phase. Mechanical durability is 10,000,000 cycles. Terminals are IP20. DIN-rail mounting is supported per IEC 60715. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- B6-30-01-F-80
ABB B6-30-01-F-80 mini contactor, manufacturer ID GJL1211003R8010. Three-pole AC contactor with three NO main contacts and one NC auxiliary contact. Rated control circuit voltage 220 to 240 V AC; coil operating limits per IEC 60947-4-1 are 0.85 to 1.1 x Uc at up to 55 °C. Rated operational power AC-3 is 4 kW at 400 V three-phase and 2.2 kW at 230 V three-phase. Rated operational voltage is 690 V AC for main and auxiliary circuits. Dimensions are 52.5 mm wide, 57.5 mm high, and 46.7 mm deep; net weight 0.17 kg. DIN-rail mounting per IEC 60715. Mechanical durability is 10,000,000 cycles. Ambient operating temperature is -25 to +55 °C.
- B6-30-01-F-84
ABB B6-30-01-F-84 mini contactor, 3-pole, with 3 NO main contacts and 1 NC auxiliary contact. Rated control circuit voltage is 110 to 127 V AC, with coil operating limits of 0.85 to 1.1 x Uc according to IEC 60947-4-1 for AC supply at ambient temperatures up to 55 °C. Rated operational power AC-3 is 2.2 kW at 230 V, 4 kW at 400 V, 4 kW at 500 V, and 3 kW at 690 V, three-phase. Dimensions are 52.5 mm wide, 57.5 mm high, and 46.7 mm deep; net weight 0.17 kg. Mechanical durability is 10,000,000 cycles. Mounting is on TH35-15 or TH35-7.5 DIN rail according to IEC 60715. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.