- 3G3MX2-AB015-V2
The OMRON 3G3MX2-AB015-V2 is a single-phase 240 VAC open and closed loop inverter with V/f, sensorless vector, and closed loop vector control. It provides a 0.01 to 590 Hz speed range, 2 HP constant torque at 8.0 A, and 3 HP variable torque. Modbus communications, flow-chart logic programming, vertical mounting, and CAT3 STO safety functionality are included.
- 3G3MX2-AB022-V2
The OMRON 3G3MX2-AB022-V2 is an open and closed loop inverter drive in the 3G3MX2 series. It operates from a 1-phase, 240 VAC supply and supports V/f, sensorless vector, and closed loop vector control. The speed range is 0.01 to 590 Hz. Rated output is 3 HP at 11.0 A in constant torque mode and 4 HP at 12.0 A in variable torque mode. Built-in communications include Modbus, and flow-chart logic programming is supported. Safety functionality includes CAT3 and STO. The unit is intended for vertical mounting.
- 3G3RX2-A2004
The OMRON 3G3RX2-A2004 is a 3-phase open and closed loop inverter (VFD) rated 240 VAC, with 1/2 HP constant torque and 3.0 A constant torque current. It supports V/f, sensorless vector, and closed loop vector control, with a speed range of 0.01 to 400 Hz. Built-in Modbus communication and flow-chart logic programming are included. Vertical mounting.
- 3G3RX2-A2007
The Omron 3G3RX2-A2007 is a three-phase open and closed loop inverter (VFD) rated 240 VAC, with 1 HP constant torque and 5.0 A constant torque current. It supports V/f, sensorless vector, and closed loop vector control, with a speed range of 0.01 to 400 Hz. Built-in Modbus communication and flow-chart logic programming are included. Vertical mounting.
- 3G3RX2-A2015
The OMRON 3G3RX2-A2015 is a 3-phase open and closed loop inverter (VFD) rated 240 VAC, 2 HP constant torque at 7.5 A. It supports V/f, sensorless vector, and closed loop vector control, with a speed range of 0.01 to 400 Hz and a starting torque value of 2. Modbus communications are built in, and flow-chart logic programming is supported. The unit mounts vertically. Overload protection ratings of 110% for 60 seconds and 120% for 3 seconds are stated in the reference material. Protective construction is IP20 and UL open type. The operating frequency range is 0.5 to 10 kHz.
- 3G3RX2-A2022
The OMRON 3G3RX2-A2022 is a 3-phase open and closed loop inverter rated 240 VAC, 3 HP constant torque at 10.5 A. It supports V/f, sensorless vector, and closed loop vector control with a speed range of 0.01 to 400 Hz. Modbus communications are built in, and flow-chart logic programming is supported. Vertical mounting.
- 3G3RX2-A2037
The Omron 3G3RX2-A2037 is a 3-phase open and closed loop inverter (VFD) rated 240 VAC, 5 HP constant torque at 16.5 A. It supports V/f, sensorless vector, and closed loop vector control, with a speed range of 0.01 to 400 Hz. Built-in Modbus communication and flow-chart logic programming are included. It mounts vertically.
- 3G3RX2-A2055
The OMRON 3G3RX2-A2055 is a three-phase open and closed loop inverter (VFD) rated 240 VAC, with 7 1/2 HP constant torque and 24 A constant torque current. It supports V/f, sensorless vector, and closed loop vector control, with a speed range of 0.01 to 400 Hz. Built-in Modbus communication and flow-chart logic programming are included. Vertical mounting.