- E3NX-MA0
The OMRON E3NX-MA0 is a two-channel fiber optic amplifier in a cuboid plastic housing for rail mounting. It uses a red LED light source and provides selectable L-ON or D-ON operation. Response time is 0.1 ms. The amplifier supports 2-in-1 double amplification, AND/OR signal comparison, power tuning, a built-in timer, and a power saving Eco function. Connection is via a communications connector; the unit is a model for a Sensor Communications Unit.
- E3NX-MA11
The Omron E3NX-MA11 is a standard fiber amplifier with a 2-in-1 double amplifier configuration and a plastic housing. It uses a red LED light source and supports selectable L-ON or D-ON operation. Supply voltage is 10-30 VDC, and the output is NPN. The unit is pre-wired and includes a built-in timer. It provides AND/OR signal comparison, power tuning, and a power-saving Eco function. The E3NX-MA11 is listed as high speed. Two sensor outputs can be configured for normal detection, AND, OR, XOR, GAP, and area detection modes. Response times as low as 100 microseconds are stated for super-high-speed mode.
- E3NX-MA41
The OMRON E3NX-MA41 is a standard fiber optic amplifier with a plastic housing and red LED light source. It provides PNP output, selectable L-ON or D-ON operation, and a supply voltage of 10-30 VDC. The pre-wired unit supports 2-in-1 double amplifier configuration, AND/OR signal comparison, power tuning, and a power saving Eco function.
- E3NX-MA6
The OMRON E3NX-MA6 is a standard 2-in-1 double fiber amplifier unit with a plastic housing and a red LED light source. It provides an NPN output and operates on a supply voltage of 10-30 VDC via a wire-saving connector. Operation is selectable between L-ON and D-ON. The unit supports AND/OR signal comparison, power tuning, and a power-saving Eco function, and includes a built-in timer. It is described as high speed. No response time, channel count, or output format beyond NPN is stated in the supplied parameters.
- E3NX-MA8
The OMRON E3NX-MA8 is a standard fiber amplifier unit in a plastic housing with a red LED light source. It is a 2-in-1 double amplifier supporting AND/OR signal comparison and high-speed operation. Light-ON and Dark-ON are selectable. Output is PNP, and supply voltage is 10-30 VDC. Connection is via a wire-saving connector. The unit includes a built-in timer, power tuning, and a power-saving Eco function. Operating temperature range is -25°C to +55°C, depending on the number of connected units. The E3NX-MA8 is intended for use with fiber optic sensing systems in industrial automation.
- E3X-CRT
The OMRON E3X-CRT is a sensor communication unit for Fiber Optic Sensors and Amplifiers. It operates on a CompoNet network and supports a maximum of 16 connectable units. The unit is intended for data transmission between connected sensor amplifiers and the network. No supply voltage, current consumption, protection ratings, environmental limits, or certification designations are supplied in the available data. The CompoNet network type and the 16-unit maximum connection count are the only specified technical parameters. Install and configure the unit according to the applicable CompoNet system requirements.
- E3X-ECT
The OMRON E3X-ECT is a fiber optic sensor amplifier for EtherCAT networks. It supports connection of up to 30 units. The amplifier is part of the E3X series and is intended for use in EtherCAT-based control systems.
- E3X-HD0
OMRON E3X-HD0 fiber optic sensor amplifier, digital type for easy usage. It supports color mark detection and differential operation. The light source is a red LED; an infrared LED is also indicated. Operation is selectable L-ON or D-ON. Supply voltage is 12-24 VDC. Super high speed mode is rated at 20 μs maximum. External input for teaching or trigger is provided, and window monitoring with twin output is listed. The housing material is plastic, and the connection type is another connector. The legacy description mentions Smart Tuning, protection circuits, and response times of 50 μs for NPN and 55 μs for PNP outputs; these figures are not confirmed by the structured parameters and are omitted.