- ESP 415T1/25/TNC
ABB ESP 415T1/25/TNC is an industrial catalog item. Key specifications include Standards: IEC 61643-11, Type of Low Voltage Distribution System: TN-C, Suitable For: To protect systems against transient overvoltages or surges from lightning and e, and Nominal AC Voltage of the System (U o ): 230 V. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- ESP 415T1/25/TNS
ABB Power SPD, model ESP 415T1/25/TNS, is a four-pole surge protective device for TN-S low-voltage distribution systems. It is intended to protect systems against transient overvoltages or surges from lightning and electrical switching events. The device is rated for a nominal AC system voltage (Uo) of 230 V at 50/60 Hz, with maximum continuous operating voltage (Uc) of 275 V and temporary overvoltage test value (UT) of 337 V. Voltage protection level (Up) is 1.5 kV. Discharge current is nominal 25 kA, maximum 65 kA, with short-circuit withstand Icc of 50 kA. Arrester class is I II. Connection is by screw clamp, wire stripping length 18 mm. It complies with IEC 61643-11. Operating ambient air temperature is -40 to +80 °C. Width is 73 mm, 4 modular spacings. Manufacturer ID 7TCA085460R0369.
- ESP 415T1/25/TT
ABB ESP 415T1/25/TT is an industrial catalog item. Key specifications include Standards: IEC 61643-11, Type of Low Voltage Distribution System: TT, Suitable For: To protect systems against transient overvoltages or surges from lightning and e, and Nominal AC Voltage of the System (U o ): 230 V. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- ESP 415T2/50/TNC
ABB ESP 415T2/50/TNC is an industrial catalog item. Key specifications include Standards: IEC 61643-21, Type of Low Voltage Distribution System: TN-C, Suitable For: To protect systems against transient overvoltages or surges from lightning and e, and Nominal AC Voltage of the System (U o ): 230 V. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- ESP 415T2/50/TNS
ABB ESP 415T2/50/TNS is an industrial catalog item. Key specifications include Standards: IEC 61643-21, Type of Low Voltage Distribution System: TN-S, Suitable For: To protect systems against transient overvoltages or surges from lightning and e, and Nominal AC Voltage of the System (U o ): 230 V. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- ESP 415T2/50/TT
ABB ESP 415T2/50/TT is an industrial catalog item. Key specifications include Standards: IEC 61643-21, Type of Low Voltage Distribution System: TT, Suitable For: To protect systems against transient overvoltages or surges from lightning and e, and Nominal AC Voltage of the System (U o ): 230 V. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- ESP 480D1
ABB ESP 480D1 is an industrial catalog item. Key specifications include Standards: IEC 61643-11, Type of Low Voltage Distribution System: TN TT, Suitable For: To protect systems against transient overvoltages or surges from lightning and e, and Nominal AC Voltage of the System (U o ): 277 V. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- ESP 480D1/LCD
ABB Power SPD, display model ESP 480D1/LCD, manufacturer ID 7TCA085460R0134. This surge protective device is intended to protect systems against transient overvoltages or surges from lightning and electrical switching events in TN TT low voltage distribution systems. It complies with IEC 61643-11 and is rated for a nominal AC system voltage (Uo) of 277 V, maximum continuous operating voltage (Uc) 350 V, and temporary overvoltage test value (UT) 402 V. Voltage protection level (Up) is 680 V. Discharge current is nominal 20 kA I and maximum 40 kA (8/20 µs). Short circuit withstand Icc is 25 kA, rated frequency 50 / 60 Hz, short-circuit protective devices ≤ 125 A, arrester class I II III, seven protected poles, screw clamp connection, remote indicator, wire stripping length 17 mm, ambient air temperature operation -40 ... +80 °C, net dimensions 170 mm x 140 mm x 95 mm.