- ESP 240D1
ABB ESP 240D1 is an industrial catalog item. Key specifications include Standards: IEC 61643-11, Suitable For: To protect systems against transient overvoltages or surges from lightning and e, Nominal AC Voltage of the System (U o ): 240 V, and Voltage Protection Level ( Up): 600 V. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- ESP 240DS-10A
ABB ESP 240DS-10A is an industrial catalog item. Key specifications include Standards: IEC 61643-11, Suitable For: To protect systems against transient overvoltages or surges from lightning and e, Nominal AC Voltage of the System (U o ): 240 V, and Voltage Protection Level ( Up): 600 V. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- ESP 240DS-32A
ABB ESP 240DS-32A is an industrial catalog item. Key specifications include Standards: IEC 61643-11, Suitable For: To protect systems against transient overvoltages or surges from lightning and e, Nominal AC Voltage of the System (U o ): 240 V, and Voltage Protection Level ( Up): 600 V. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- ESP 240M1
ABB ESP 240M1 is an industrial catalog item. Key specifications include Standards: IEC 61643-11, Type of Low Voltage Distribution System: TN TT, Suitable For: To protect systems against transient overvoltages or surges from lightning and e, and Nominal AC Voltage of the System (U o ): 240 V. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- ESP 240T1/12.5/M
ABB ESP 240T1/12.5/M is an industrial catalog item. Key specifications include Standards: IEC 61643-11, Type of Low Voltage Distribution System: TN TT, Suitable For: To protect systems against transient overvoltages or surges from lightning and e, and Nominal AC Voltage of the System (U o ): 230 V. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- ESP 240T1/25/M
ABB Power SPD, model ESP 240T1/25/M, manufacturer ID 7TCA085460R0374. This surge protective device is intended to protect systems against transient overvoltages or surges from lightning and electrical switching events. It is suitable for TN TT low voltage distribution systems and complies with IEC 61643-11. The nominal AC system voltage is 230 V at 50 / 60 Hz, with maximum continuous operating voltage 275 V and temporary overvoltage test value 337 V. Voltage protection level is 1.5 kV. Discharge current is 25 kA nominal and 65 kA maximum; short circuit withstand is 50 kA. Arrester class I II, one protected pole, push-in connection, remote indicator, 1 modular spacing, operation from -40 to +80 °C.
- ESP 240T1/25/TNC
ABB Power SPD, display model ESP 240T1/25/TNC, manufacturer ID 7TCA085400R0500. Intended to protect systems against transient overvoltages or surges from lightning and electrical switching events. For TN-C low voltage distribution systems, nominal AC system voltage 230 V, rated frequency 50 / 60 Hz, maximum continuous operating voltage 275 V, temporary overvoltage test value 337 V, voltage protection level 1.5 kV. Discharge current nominal 25 kA, maximum 65 kA; short-circuit withstand Icc 50 kA; short-circuit protective devices up to 315 A. Arrester class I II, one protected pole, screw clamp connection, wire stripping length 18 mm, remote indicator provided. Auxiliary circuit load 250 Vac - 1 A. Ambient air temperature operation -40 to +80 °C. Width 18 mm, one modular spacing. Standards: IEC 61643-11.
- ESP 240T1/25/TNS
ABB Power SPD, model ESP 240T1/25/TNS, is a two-pole surge protective device for TN-S low-voltage distribution systems, intended to protect systems against transient overvoltages or surges from lightning and electrical switching events. It complies with IEC 61643-11 and is arrester class I II. Nominal AC system voltage is 230 V at 50 / 60 Hz, with maximum continuous operating voltage 275 V, temporary overvoltage test value 337 V, and voltage protection level 1.5 kV. Discharge current is nominal 25 kA, maximum 65 kA; short-circuit withstand Icc is 50 kA. Short-circuit protective devices are rated up to 315 A. Connection is screw clamp with 18 mm wire stripping length. Operation is -40 to +80 °C. Width is 2 modular spacings, 36.5 mm. A remote indicator is included.