- NX-TS2102
The OMRON NX-TS2102 is a thermocouple input unit in the NX remote I/O series. It provides two analog thermocouple inputs supporting K, J, T, E, L, U, N, R, S, B, WRe5-26, and PLII types. Resolution is 0.01°C with a conversion time of 10 ms/unit. Accuracy at 25°C is ±0.1% to 0.25% depending on range. The module is 12 mm wide, mounts on DIN rail, and uses a removable screwless clamping terminal block. An NX-PF power supply is required. NX power consumption is 0.8 W. The reference manual is W522.
- NX-TS2104
The OMRON NX-TS2104 is a remote I/O thermocouple input module for DIN rail mounting. It provides two analog thermocouple inputs supporting K, J, T, E, L, U, N, R, S, B, WRe5-26, and PLII types. Resolution is 0.001°C with a conversion time of 60 ms per unit. Accuracy at 25°C is ±0.1% to 0.25% depending on range. The module uses a removable screwless clamping terminal block and requires an NX-PF power supply. Power consumption is 0.8 W and module width is 12 mm. Reference manual W522 applies. The legacy description's IP20 rating is omitted because it is not supplied in the structured parameters.
- NX-TS2201
The OMRON NX-TS2201 is a remote I/O temperature input unit with two analog RTD inputs supporting PT100 (3-wire), PT1000, and Ni508.4 sensors. It provides 0.1°C resolution and a conversion time of 250 ms per unit. Accuracy at 25°C is ±0.1% to 0.25% depending on range. The unit mounts on DIN rail, requires an NX-PF power supply, and consumes 0.9 W from the NX bus. It has a 12 mm module width and a removable screwless clamping terminal block. The reference manual is W522. This module is intended for use within the NX I/O Bus architecture.
- NX-TS2202
The OMRON NX-TS2202 is a remote I/O temperature input unit with two analog inputs for RTD sensors: PT100 (3-wire), PT1000, and Ni508.4. It provides 0.01°C resolution and a conversion time of 10 ms per unit. Accuracy at 25°C is ±0.1% to 0.25% depending on range. The module mounts on DIN rail, requires an NX-PF power supply, and consumes 0.75 W. It uses a removable screwless clamping terminal block. Module width is 12 mm. Manual W522 is referenced. The legacy description's claims of safety functionality and suitability for safety-critical applications are omitted because they are not supported by the supplied structured parameters.
- NX-TS2204
The OMRON NX-TS2204 is a remote I/O temperature input unit with two RTD analog inputs supporting PT100 (3-wire), PT1000, and Ni508.4 sensors. It provides 0.001°C resolution with a conversion time of 60 ms/unit and accuracy at 25°C of ±0.1% to 0.25% depending on range. The module mounts on DIN rail, requires an NX-PF power supply, and consumes 0.75 W. It uses a removable screwless clamping terminal block and has a module width of 12 mm. Manual W522 is referenced. No safety rating, certification, or standard is stated in the supplied data.
- NX-TS3101
The OMRON NX-TS3101 is a DIN rail-mount temperature input module with four thermocouple inputs supporting K, J, T, E, L, U, N, R, S, B, WRe5-26, and PLII types. It provides 0.1°C resolution and a conversion time of 250 ms per unit, with accuracy at 25°C of ±0.1% to 0.25% depending on range. The module has a removable screwless clamping terminal block, a 24 mm width, and 1.3 W power consumption. An NX-PF power supply is required.
- NX-TS3102
The OMRON NX-TS3102 is a thermocouple input unit in the NX remote I/O series. It provides four analog thermocouple inputs supporting types K, J, T, E, L, U, N, R, S, B, WRe5-26, and PLII. Resolution is 0.01°C with a conversion time of 10 ms per unit. Accuracy at 25°C is ±0.1% to 0.25% depending on range. The module mounts on DIN rail, requires an NX-PF power supply, and consumes 1.1 W. It uses a removable screwless clamping terminal block and has a module width of 24 mm. Reference manual W522 applies.
- NX-TS3104
The OMRON NX-TS3104 is a DIN rail-mount remote I/O temperature input unit with four thermocouple input channels. It accepts K, J, T, E, L, U, N, R, S, B, WRe5-26, and PLII thermocouple types. Resolution is 0.001°C with a conversion time of 60 ms per unit. Accuracy at 25°C is ±0.1% to 0.25% depending on range. The unit consumes 1.1 W from the NX power supply, which is required. It uses a removable screwless clamping terminal block and has a module width of 24 mm. Documentation is provided in manual W522. The legacy description's IO-Link master compatibility claim is not supported by the supplied parameters and is omitted.