- AF228P-PG
ABB AF228P-PG is an industrial catalog item. Key specifications include Product Net Width: 86 mm, Product Net Height: 40 mm, Product Net Depth / Length: 86 mm, and Product Net Weight: 95 g. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- AF23-111-A11-992-0
ABB AF23-111-A11-992-0 is an industrial catalog item. Key specifications include ABB Type Designation: -, Frame Size: Undefined, Gross Weight: 0 kg, and Made To Order: No. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- AF23-213-A22-772-0
ABB product identified by display model AF23-213-A22-772-0 and manufacturer ID AF23-213-A22-772-0. The invoice description lists RB1000i-MC ass'y (7 Color). No ABB type designation, product type, or frame size is supplied; these fields are marked undefined. Net weight is 14 kg and gross weight is 17 kg. The item is not made to order and is not quote only. Order multiple is 1 piece. Stocked at warehouses in Japan. No technical ratings, standards, certifications, or applications are provided in the source data.
- AF26-22-00-11
ABB AF26-22-00-11 is a 4-pole AC contactor with 2 NO and 2 NC main contacts and no auxiliary contacts. It has screw terminals and an electronic coil interface. Rated control circuit voltage is 24 to 60 V at 50 Hz and 60 Hz, and 20 to 60 V DC. Rated operational voltage for the main circuit is 690 V, with rated frequency 50/60 Hz. Rated operational current AC-3 is 22 A at 380/400 V and 60 °C, and rated operational power AC-3 is 11 kW at 400 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, and CAN/CSA C22.2 No.60947-4-1. Dimensions are 45 mm wide, 101 mm deep, and 86 mm high; net weight is 0.36 kg.
- AF26-22-00-12
The ABB AF26-22-00-12 is an AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It is rated 690 V in the main circuit and 48 to 130 V AC/DC at 50 or 60 Hz in the control circuit. Rated operational current AC-1 is 45 A at 690 V and 40 °C, and AC-3 is 22 A at 380/400 V and 60 °C, corresponding to 11 kW at 400 V. It measures 45 mm wide, 101 mm deep, and 86 mm high, weighs 0.36 kg, and mounts on TH35-15 or TH35-7.5 DIN rail or on two M4 screws. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, and CAN/CSA C22.2 No.60947-4-1.
- AF26-22-00-13
The ABB AF26-22-00-13 is an AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It measures 45 mm wide, 101 mm deep, and 86 mm high, and weighs 0.36 kg. The main circuit is rated 690 V at 50/60 Hz, with a rated insulation voltage of 690 V according to IEC 60947-4-1 and 600 V according to UL/CSA, and a rated impulse withstand voltage of 6 kV. Rated operational current AC-3 is 22 A at 380/400 V and 60 °C, and rated operational power AC-3 is 11 kW at 400 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, and CAN/CSA C22.2 No.60947-4-1.
- AF26-22-00-14
The ABB AF26-22-00-14 is an AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It measures 45 mm wide, 101 mm deep, and 86 mm high, and weighs 0.4 kg. The main circuit is rated 690 V, with a rated insulation voltage of 690 V according to IEC 60947-4-1 and 600 V according to UL/CSA, and a rated impulse withstand voltage of 6 kV. Rated operational current AC-3 is 22 A at 380/400 V and 60 °C, 21.2 A at 415 V and 60 °C, and 20 A at 440 V and 60 °C. Rated operational power AC-3 is 11 kW at 400 V, 415 V, 440 V, and 500 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, and CAN/CSA C22.2 No.60947-4-1.
- AF26-30-00-11
The ABB AF26-30-00-11 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 86 mm high, and weighs 0.31 kg. The main circuit is rated 690 V at 50/60 Hz. Rated operational current AC-3 is 26 A at 415 V and 60 °C, 23 A at 500 V, and 17 A at 690 V. Rated operational power AC-3 is 11 kW at 400 V and 15 kW at 440 V. Conventional free-air thermal current is 50 A per IEC 60947-4-1 for open contactors at 40 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.