Industrial Automation Parts. Prompt replies from real people.

SICK ARS60-AAA04096 Absolute Singleturn Encoder

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/24/2026

Q1Can you supply the SICK ARS60-AAA04096?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the SICK ARS60-AAA04096 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
ARS60-AAA04096
Material Number
1031431
Manufacturer
SICK
Product ID
58511

Get a Free Quote

Request pricing and availability for ARS60-AAA04096.

More parts to source? Send your whole list in one enquiry

Key specifications

Supply voltage
10 ... 32 V
Operating current
Typ. 60 mA
Weight
Approx. 0.3 kg 2)
Operating temperature range
–20 °C ... +85 °C
See all specifications

Product Highlights

  1. Resolution: 4096 steps per revolution
  2. Housing: Aluminum die-cast
  3. Protection rating: IP65 against dust and water
  4. Operating temperature range: -20°C to +85°C
  5. Design: Compact with blind hollow shaft
ARS60-AAA04096

Product Information

Technical Specifications

Specifications for ARS60-AAA04096

ParameterValue
Number of steps per revolution (max. resolution)4,096 (12 bit)
Measuring step360° /number of steps
Measuring step deviation0.005° binary number of steps
Repeatability standard deviation σr0.005° 2)
Supply voltage10 ... 32 V
Operating currentTyp. 60 mA
Connection typeMale connector, M23, 12-pin, radial
Shaft diameter15 mm 1)
ParameterValue
WeightApprox. 0.3 kg 2)
Housing materialAluminum die cast
Enclosure ratingIP65, male connector (IEC 60529) 2)
MTTFD (mean time to dangerous failure)300 years (EN ISO 13849-1) 1)
Permissible relative humidity90 % (Condensation not permitted)
Operating temperature range–20 °C ... +85 °C
Error limits G0.035° (binary number of steps) 1)