- ESP 480M1R
ABB ESP 480M1R is an industrial catalog item. Key specifications include Standards: IEC 61643-11, Type of Low Voltage Distribution System: TN TT, Suitable For: To protect systems against transient overvoltages or surges from lightning and e, and Nominal AC Voltage of the System (U o ): 277 V. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- ESP 480M2
ABB Power SPD, display model ESP 480M2, manufacturer ID 7TCA085460R0138. This surge protective device is intended to protect systems against transient overvoltages or surges from lightning and electrical switching events in TN TT low voltage distribution systems. It complies with IEC 61643-11 and is rated for a nominal AC system voltage of 277 V at 50 / 60 Hz, with maximum continuous operating voltage 350 V, temporary overvoltage test value 402 V, and voltage protection level 680 V. Discharge current is nominal 20 kA with maximum 80 kA at 8 / 20 µs; short circuit withstand is 25 kA. Arrester class I II III, seven protected poles, screw clamp connection, 17 mm wire stripping length, remote indicator. Dimensions: 226 mm width, 204 mm height, 78 mm depth. Operating ambient air temperature -40 to +80 °C.
- ESP 480M4
ABB ESP 480M4 power surge protective device (SPD), manufacturer ID 7TCA085460R0140. It is intended for TN and TT low-voltage distribution systems to protect against transient overvoltages from lightning and electrical switching events. It complies with IEC 61643-11 and is classified as arrester class I, II, III. The nominal AC system voltage is 277 V, with a maximum continuous operating voltage of 350 V and a temporary overvoltage test value of 402 V. Voltage protection level is 680 V. Discharge current is 25 kA nominal (8/20 µs) and 150 kA maximum. Short-circuit withstand is 25 kA, with short-circuit protective devices up to 315 A. Rated frequency is 50/60 Hz. It has seven protected poles, screw clamp connections, a remote indicator, and a 17 mm wire stripping length. Operating ambient air temperature is -40 to +80 °C. Dimensions are 226 mm wide, 204 mm high, and 125 mm deep.
- ESP 480M4R
ABB ESP 480M4R is an industrial catalog item. Key specifications include Standards: IEC 61643-11, Type of Low Voltage Distribution System: TN TT, Suitable For: To protect systems against transient overvoltages or surges from lightning and e, and Nominal AC Voltage of the System (U o ): 277 V. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- ESP 480T2/50/TNC
ABB Power SPD, model ESP 480T2/50/TNC, manufacturer ID 7TCA085460R0395. This surge protective device is intended to protect systems against transient overvoltages or surges from lightning and electrical switching events. It is rated for 50 / 60 Hz and operates over an ambient air temperature range of -40 to +80 °C. The product is specified to IEC 61643-21.
- ESP 480T2/50/TNS
ABB ESP 480T2/50/TNS is an industrial catalog item. Key specifications include Standards: IEC 61643-21, Suitable For: To protect systems against transient overvoltages or surges from lightning and e, Rated Frequency (f): 50 / 60 Hz, and Ambient Air Temperature: Operation -40 ... +80 °C. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- ESP 480T2/50/TT
ABB ESP 480T2/50/TT is an industrial catalog item. Key specifications include Standards: IEC 61643-21, Suitable For: To protect systems against transient overvoltages or surges from lightning and e, Rated Frequency (f): 50 / 60 Hz, and Ambient Air Temperature: Operation -40 ... +80 °C. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- ESP 48DC
ABB ESP 48DC is an industrial catalog item. Key specifications include Standards: IEC 61643-11, Suitable For: To protect systems against transient overvoltages or surges from lightning and e, Nominal AC Voltage of the System (U o ): 48 V, and Voltage Protection Level ( Up): 190 V. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.