- FH110-D-T2H-R
The CKD FH110-D-T2H-R is a parallel hand in the FH1 series with a 10 mm bore. It is double acting (option D) and has a stroke length of 12 mm. The unit is configured without a small jaw and without an end mount. A proximity switch is fitted: T2 type, one colour, two wire, with the lead wire exiting axially and a standard 1 m lead length. Switch quantity R denotes one switch on the right (port) side at the open position. The speed control valve length is 0.0 mm. The legacy description mentions a maximum working pressure of 0.7 MPa and an ambient operating temperature range of 5°C to 60°C.
- FH112-D
The CKD FH112-D is a parallel hand with a 12 mm bore and a 15 mm length. It is double acting (option D) and is supplied without a small jaw or end mount. The speed control valve length is 0.0 mm.
- FH112-D-T2H-R
CKD FH112-D-T2H-R parallel hand with 12 mm bore, configured for double-acting operation. It uses a T2 proximity switch, 1 color, 2 wire, with axial lead wire direction and 1 m standard lead wire length. Switch quantity is one on the right (port) side open position. Length is 15 mm. Supplied without small jaw and without end mount.
- FH116-D
CKD FH116-D parallel hand with FH1 type, 16 mm bore, and D option for standard double acting operation. Supplied without a small jaw and without an end mount. Length is 21 mm. The speed control valve length is 0.0 mm.
- FH116-D-T2H-R
CKD FH116-D-T2H-R parallel hand with 16 mm bore, double-acting standard configuration, and no small jaw. It uses a T2 proximity switch, one color, two wire, with axial lead wire direction and 1 m standard lead length. The switch is mounted on the right (port) side open position. Length is 21 mm. End mount is not included.
- FH120-D
CKD FH120-D parallel hand gripper, type FH1, with a 20 mm bore size. The D option denotes standard double-acting operation. Supplied without a small jaw and without an end mount. Length is 25 mm, and the speed control valve length is 0.0 mm.
- FH120-D-T2H-R
CKD FH120-D-T2H-R parallel hand, FH1 type, 20mm bore, double acting (option D). Supplied without a small jaw and without an end mount. The switch is a T2 proximity type, one color, two wire, with the lead wire exiting axially (H) and a standard 1m lead length. Switch quantity R denotes one switch on the right (port) side open position. Length is 25mm; speed control valve length is 0.0mm. The model code FH120-D-T2H-R identifies this configuration. No further ratings, operating pressures, or certifications are stated in the supplied data.
- FH125-D
CKD FH125-D parallel hand, type FH1, with a 25 mm bore and double-acting operation. Operating stroke length is 8, 11, 14, 18, or 20 mm. The unit has a length of 26 mm and is supplied without a small jaw or end mount. Speed control valve length is 0.0 mm.