- FCK-5-C-N1
CKD FCK-5-C-N1 shock absorber for industrial use. It provides adjustable impact energy absorption and is intended for high-speed applications. The design targets precision and reliability in industrial installations. Model number FCK-5-C-N1 identifies this unit within the CKD shock absorber range.
- FCK-5-N1
CKD FCK-5-N1 is listed in the Shock absorbers category. Key specifications include 1.Adjustable Impact Energy Absorption: "Easily adjust the impact energy absorption performance accor, 2.High Efficiency Threading: "Features an externally threaded outer pipe with a large surface area,, and 3.Wide Operating Temperature Range: "Operates effectively in a wide temperature range of -5°C to 70°. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- FCK-6.5-C-N1
CKD FCK-6.5-C-N1 shock absorber. The supplied reference text describes an adjustable shock absorber with a single-hole orifice structure for low-speed applications, adjustable impact energy absorption, and an operating temperature range of -5 to 70°C. No authoritative structured parameters, ratings, or order codes were supplied, so performance figures and application claims from the reference text cannot be verified. The reference text also describes high-speed performance, which conflicts with the stated low-speed orifice design; that claim is omitted. Confirm stroke, impact energy capacity, mounting thread, and adjustment range against CKD documentation before selection.
- FCK-8.1-A
CKD FCK-8.1-A adjustable shock absorber. The legacy description states an operating temperature range of -5 to 70°C and lists thread sizes M10 x 1.0, M12 x 1.0, and M14 x 1.5 with stroke lengths of 8, 10, and 12 mm. These values are legacy reference data and are not confirmed by authoritative parameters. No electrical ratings, load capacity, energy absorption per cycle, mounting style, or standard designations are supplied. The adjustment mechanism is described as adjustable, but no adjustment range or method is specified. No compatibility, certification, or application claims are made here. Verify all dimensions, temperature limits, and performance data against the current CKD datasheet before specifying.
- FCK-8.1-C-N1
The CKD FCK-8.1-C-N1 is a shock absorber with an adjustable orifice method for tuning to specific operating conditions. It absorbs up to 79.3 J of energy per cycle. Construction uses materials selected for resistance to repeated impact loading.
- FCK-8.1-N1
The CKD FCK-8.1-N1 is a shock absorber with adjustable impact energy absorption. It is intended for high-speed applications and operates within a temperature range of -5 to 70°C. The model allows adjustment of impact energy absorption to suit the application. No further performance ratings, load capacities, stroke lengths, or thread sizes are stated.
- FCK-L-0.15
CKD FCK-L-0.15 shock absorber. The FCK-L designation indicates low-speed operation, and the 0.15 series provides a maximum energy absorption of 1.5 J. The blank option denotes a version without a cap. Dimensions include A 58.9 mm, A* 65.2 mm, B 3.5 mm, C 50.9 mm, ST 8 mm, D 1.5 mm, E 6.3 mm, F 3.0 mm, G 8.7 mm, H 14.2 mm, I 6.0 mm, J M10x1, K 2.4 mm, N 42.2 mm, and M 13 mm. The operating temperature range is -5 to 70°C. Impact energy absorption is adjustable. The externally threaded outer pipe is intended to release heat.
- FCK-L-0.3
CKD FCK-L-0.3 shock absorber. The FCK-L designation indicates low-speed operation, and the 0.3 series provides a maximum energy absorption of 2.9 J. The blank option denotes a version without cap. Dimensions include A 76.0 mm, A* 84.0 mm, C 66.0 mm, ST 10 mm, D 1.5 mm, E 8.0 mm, F 4.0 mm, G 5.0 mm, H 16.2 mm, I 8.0 mm, J M12x1, K 3.5 mm, N 61.0 mm, and M 14 mm. B is not specified. The legacy text mentions three shock absorbing mechanisms, a single hole orifice structure, multiple thread sizes and stroke lengths, and an operating temperature range of -5 to 70°C; these details are not confirmed by the structured parameters.