- MWD30-25-F
CKD sanitary system, model MWD30-25-F. Series 3, size 3, with a 25A (1S) clamp fitting port. The material combination is F: A5056 actuator, PTFE/EPDM diaphragm, and SUS316L body. Dimensions are A 127 mm, B 88.7 mm, H 50.5 mm, K 23.0 mm, and N 69 mm.
- MWD40-40-F
CKD sanitary system valve, display model MWD40-40-F. Model number MWD4, size 4, with a 40A (1.5S) clamp fitting port. The F configuration combines an A5056 actuator, PTFE/EPDM diaphragm, and SUS316L body. Dimensions are A 159 mm, B 107.6 mm, H 50.5 mm, K 35.7 mm, and N 89 mm.
- MWD50-50-F
The CKD MWD50-50-F is a sanitary system valve. Its model number is MWD5, with series 5 indicating size 5. The port size is 50, a clamp fitting 50A (2S). The actuator, diaphragm, and body material combination is F: actuator A5056, diaphragm PTFE/EPDM, and body SUS316L. Dimensional data are A 190mm, B 164.5mm, H 64.0mm, K 47.8mm, and N 89mm. No pressure rating, temperature range, flow coefficient, standard, or certification is supplied for this configuration, so none is stated here. The available specifications are limited to the model designation, port size, material combination, and the listed dimensions.
- SPD-1108YF1
The CKD SPD-1108YF1 is a sanitary system component in the 1 series with size 1. It has an NC function and an 8A port size. The connection is an ISO ferrule. Materials are ACT A5056, body SUS316L, and DP PTFE. Port direction is direction 1.
- SWD-EVD1-0AN
The CKD SWD-EVD1-0AN is an electro-pneumatic regulator in the SWD series. It accepts a 0-10 VDC input and provides a 1-5 V analog output with an NPN error signal. Linearity is ±0.3% F.S. and hysteresis is 0.5% F.S. The unit supports IO-Link communication and includes a digital display for control status. The D-sub connector is positioned at 0.
- SWD11-10-F
Product identification: CKD SWD11-10-F. The SWD11-10-F is a sanitary system component with dimensions A 90 mm, B 101.0 mm, C 22 mm, D 61.5 mm, E 7.0 mm, H 34.0 mm, K 14.0 mm, M 32.0 mm, and N 40.0 mm. It is identified by model number SWD11-10-F.
- SWD11-8-F
The CKD SWD11-8-F is a sanitary system component with the following dimensions: A 90 mm, B 99.5 mm, C 22 mm, D 60.0 mm, E 7.0 mm, H 34.0 mm, K 10.5 mm, M 32.0 mm, and N 40.0 mm. It is identified by model number SWD11-8-F within the CKD sanitary system category.
- SWD11-8-FC
CKD sanitary system valve, model SWD11-8-FC. The model no. is SWD1, with port size 8A. Valve operation type is 1 (NC), and the valve option is C (flow control type). Dimensions are A 90 mm, B 99.5 mm, C 22 mm, D 60.0 mm, E 7.0 mm, H 34.0 mm, K 10.5 mm, M 32 mm, and N 40.0 mm. No pressure rating, temperature range, body material, connection standard, or certification is supplied for this item, so none is stated here. The description is limited to the identity and dimensions listed above.