- FCM-9500AI-H60AN
The CKD FCM-9500AI-H60AN is a flow rate sensor/controller for compressed air and nitrogen gas, covering 0 to 0.5 l/min. It uses a platinum sensor chip with silicon micromachining and a resin body with a φ6 push-in port. Flow rate is shown on a 3-digit digital display with error indication. Input is analog 0-10 VDC; output is 1-5 V analog error (NPN). Display direction is forward.
- FCM-9500AI-H6C
CKD FCM-9500AI-H6C is a flow rate sensor/controller for compressed air and nitrogen gas. Flow rate range is 0 to 0.5 l/min. It uses a push-in φ6 port with a resin body and an IO-Link input specification. The display direction is forward. No cable, bracket, or traceability option is included.
- FSM-V-AH3-R0005-H2
The CKD FSM-V-AH3-R0005-H2 is an analog output flow rate sensor in the FSM-V series. It provides a flow rate range of ± 0.05 l/min and uses a straight-type fitting for Ø1.8 fiber tube. The lead wire outlet is straight with a 3 mm lead wire length.
- FSM-V-DN-R0005
The CKD FSM-V-DN-R0005 is a flow rate sensor/controller in the FSM-V-D series with switch output (NPN). Its flow rate range is ± 0.05 l/min. Accuracy is 5% F.S. or less.
- FSM-VFM-H22
The CKD FSM-VFM-H22 is a flow rate sensor/controller in the FSM-VFM series. It accommodates a φ 1.8 fiber tube with an H22 tube O.D. The unit is supplied without a bracket. The catalog content for this model does not provide further electrical, mechanical, or performance specifications.
- FSM-X-AF005
The CKD FSM-X-AF005 is a uni-directional flow rate sensor with analog output and a full-scale range of 0.5 l/min. It is supplied as a single sensor head without fitting or cable. The miniature body supports integration into space-constrained installations. Accuracy is ±3% F.S. The sensor is suitable for gases including compressed air and nitrogen.
- FSM2-D-NV
The CKD FSM2-D-NV is a display-integrated flow rate sensor in the FSM2-D series. It provides two NPN switch outputs and one analog voltage output of 1-5 V. Linearity is ±3% F.S., and temperature characteristics are ±0.2% F.S./°C. The sensor measures flow in both directions. Its reduced body size suits space-constrained installations. No cable, bracket, or clean room option is included.
- FSM3-B005U1BH1J1N-C
The CKD FSM3-B005U1BH1J1N-C is a unidirectional flow rate sensor for air, with a full-scale flow rate of 500 mL/min and accuracy within ±3% F.S. It has a bar display and a resin body. The push-in port accepts a φ4 mm tube, and piping direction is straight. Output is one analog voltage output. The unit is supplied with a 4-conductor 1 m lead wire and SI units only. No valve is fitted.