- DSG-15-AC100V
The CKD DSG-15-AC100V is a gas combustion system valve with a 15 port size and standard configuration. It operates on AC100V at 50/60Hz. Dimensions are H1 91mm, H2 17.5mm, H3 67mm, and L1 69mm. A built-in strainer prevents foreign matter such as dust from entering the valve.
- DSG-20-AC100V
The CKD DSG-20-AC100V is a gas combustion system valve with a 20 port size and standard configuration. It operates on AC100V at 50/60Hz. Dimensions are H1 95mm, H2 27.5mm, H3 71mm, and L1 89mm. The valve provides adjustable flow control and includes built-in strainers to capture foreign matter.
- DSG-20-W-AC100V
The CKD DSG-20-W-AC100V is a gas valve with an Rp3/4 port size and a built-in strainer that prevents foreign matter such as dust from entering the valve. It operates on AC100V at 50/60Hz. Dimensions are H1 95mm, H2 28.5mm, L1 165mm, L2 55mm, and D 56mm. The valve is designed for hydrogen gas service.
- DSG-25-AC100V
The CKD DSG-25-AC100V is a gas combustion system valve with a 25 port size and standard configuration. It operates on AC100V at 50/60Hz. Dimensions are H1 95mm, H2 27.5mm, H3 71mm, and L1 89mm. A built-in strainer prevents foreign matter such as dust from entering the valve.
- GHV-G-D00-AC100V
The CKD GHV-G-D00-AC100V is a gas combustion valve assembly combining a solenoid valve with a built-in governor and a second solenoid valve. It has no flange and no additional options. The coil is rated 100VAC at 50Hz/60Hz. The face-to-face integration dimension is 1/3 (50A) relative to conventional designs.
- GRV-11L40S1-NNN
The CKD GRV-11L40S1-NNN is a gas combustion system component. Its control configuration is ON-OFF. The secondary orifice is Φ15. The actuator mounting direction is L. The port size is 40S, corresponding to 40A flange connection. The voltage is AC100V at 50Hz/60Hz. Primary side option is N (none), secondary side option is N (none), and no pressure gauge is included. The other options field is blank, indicating city gas or LPG. The model number GRV-11L40S1-NNN should be used for identification. No additional performance, certification, or application data is supplied.
- GRV-A
The CKD GRV-A is a medium pressure gas combination valve that integrates a governor with a secondary side shut-off valve. It uses hydraulic drive for slow open and quick shut operation. The pressure adjustment range is 10 kPa to 150 kPa. The included pressure gauge has a range of 0 to 0.4 MPa. The face-to-face design is 20% smaller than the conventional TAC-25, and flow rate at the same differential pressure is increased by 300% compared with the TAC-25. The GRV-A is compatible with hydrogen gas; a red bonnet and a hydrogen nameplate identify the hydrogen gas line. The model number is GRV, and the pressure gauge designation is A.
- HK1-40-AC100V
CKD HK1-40-AC100V solenoid valve for gas combustion systems. Model HK, ON-OFF 2-position control, 3-port, oil-free operation. Port size 40, screw-in Rp1 1/2. Coil rated 100 VAC 50/60 Hz. Supplied without terminal box, without micro switch, standard outdoor configuration, no options. Dimensions: H1 324 mm, H2 114 mm, L1 210 mm, L2 70 mm.