- HYA-221
CKD HYA-221 air operated fine pinch valve. Model HYA-22, normally open actuation. Compatible tube range 1/4" to 3/8" (φ6 to φ10) with tube wall thickness 1/32". The pneumatic drive generates sealing load without heat generation. Dimensions: A 35mm, B 48mm, C 57.5mm, D 2mm, E 8.0mm, F 16.0mm, G 89.0mm, H 45.0mm, J 11mm, K 18mm, L 70mm, M 60mm, N 48mm, P M5mm, X1 14.5mm, R1 11.0mm, R2 5.5mm, X2 14.5mm, X3 25mm, X4 6.5mm, R3 1.5mm, bore 20. The slit tube holder allows tube attachment and detachment.
- HYA-232
CKD HYA-232 air operated fine pinch valve. Actuation is normally open. Compatible tube outer diameter range is 7/16 in to 9/16 in (10 mm to 15 mm), with a tube wall thickness of 1/16 in. The valve body dimensions include A 40 mm, B 54 mm, C 73.5 mm, G 118.0 mm, H 58.0 mm, L 80 mm, M 70 mm, and N 54 mm; bore size is 25. The tube holder function in the slit allows tubes to be attached and detached for maintenance. Pneumatic actuation generates no heat when energized. No manufacturer part number or order code is supplied in the authoritative data.
- HYA-311
CKD HYA-311 component for life science applications. The model designation is HYA-31 with double-acting actuation. It accepts compatible tube sizes from 1/8 in to 7/32 in (3 mm to 6 mm) with a tube wall thickness of 1/32 in. The bore is 16. Dimensional data include A 28 mm, B 39 mm, C 49.0 mm, D 2 mm, E 5.5 mm, F 16.0 mm, G 78.0 mm, H 40.0 mm, J 7 mm, K 15 mm, L 60 mm, M 50 mm, N 39 mm, P M5 mm, X1 12.0 mm, R1 8.5 mm, R2 3.5 mm, X2 12.0 mm, X3 16 mm, X4 5.0 mm, and R3 1.5 mm. No pressure rating, standard, or certification is supplied.
- HYA-321
The CKD HYA-321 is an air-operated fine pinch valve in the Components for Life Science category. It uses double-acting pneumatic actuation and accepts tubing with an outer diameter from 1/4 in to 3/8 in (approximately 6 mm to 10 mm) and a wall thickness of 1/32 in. The valve body has a 20 mm bore. Key dimensions include 35 mm (A), 48 mm (B), 57.5 mm (C), 89.0 mm (G), 45.0 mm (H), 70 mm (L), 60 mm (M), and 48 mm (N), with an M5 port (P). The construction produces no heat generation, and the tube holder supports maintenance. The supplied data does not state a pressure rating, temperature range, or compliance with any standard.
- HYA-332
CKD HYA-332 air-operated fine pinch valve. The supplied model designation is HYA-33, with actuation specified as 3 (double acting). Compatible tube range is 7/16 in to 9/16 in (φ10 to φ15), with a tube wall thickness of 1/16 in. Bore is 25. Dimensions include A 40 mm, B 54 mm, C 73.5 mm, D 2 mm, E 11.0 mm, F 20.5 mm, G 113.0 mm, H 58.0 mm, J 16 mm, K 20 mm, L 80 mm, M 70 mm, N 54 mm, P M5 mm, X1 20.0 mm, R1 13.5 mm, R2 8.0 mm, X2 20.0 mm, X3 30 mm, X4 7.0 mm, and R3 2.0 mm. The legacy description's φ3 to φ6 tube range conflicts with the structured tube data and is omitted.
- HYN-2-AC100V
The CKD HYN-2-AC100V is a solenoid valve with a rated voltage of 100 VAC at 50/60 Hz. It includes a surge suppressor. The valve has a φ2xφ0.5 code/content specification. Dimensions are A 72.9 mm, B 52.9 mm, C 20 mm, D 14.1 mm, E 8.5 mm, F 14 mm, G 30 mm, H 24.0 mm, and J 8 mm.
- HYN-3-AC100V
CKD HYN-3-AC100V solenoid pinch valve, model HYN-3, with tube code 3 for φ3 x φ1 tubing. Rated voltage is AC100V at 100 VAC, 50/60 Hz. The valve is a component for life science equipment. Dimensional data: A 81.5 mm, B 57.5 mm, C 24 mm, D 17.0 mm, E 10.0 mm, F 16 mm, G 34 mm, H 28.0 mm, J 9 mm, K 28.0 mm, M 34 mm, N 28 mm, Q 0.0 mm, R 0 mm. Mounting provisions are 4 x M3 depth 7 mm and 2 x M3 depth 5 mm. No manufacturer part number or order code is supplied.
- HYN-5-AC100V
The CKD HYN-5-AC100V is a fine pinch valve in the Components for Life Science category. The model number is HYN-5, with code 5 denoting a tube size of φ5xφ3. It is rated for AC100V at 50/60 Hz. Dimensional data include A 98.0mm, B 65.0mm, C 33mm, D 23.0mm, E 13.0mm, F 25mm, G 43mm, H 36.5mm, J 11mm, K 36.5mm, M 43mm, N 0mm, P 0mm, and Q 36.5mm. Mounting provisions are 4 x M4 depth 7mm at positions L and R. No operating temperature range is stated in the supplied parameters.